I want to search for...
Permit #2024120585
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7022-00330-0340 |
| Block: 00330 |
| Subdivision: 7022 - |
| Job Phone: 386-898-3419 |
| Location Address: 70 WESTHAMPTON DR |
| Type: DR - DRIVEWAY |
| Issue Date: 12/18/2024 |
| NOC: Unknown |
| Applicant name: PAULO JM DOS SANTOS |
| Owner: CICHOCKI STANISLAW J & DOROTA B CICHOCKA H&W |
|
Address 70 WESTHAMPTON DRIVE PALM COAST, FL 32164 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤2,400.00 |
| Job Description: Add new 16' wide concrete semi-circle driveway |
| Type: CN |
Contractor
C & P CONCRETE INC
| Status | Location Address | Phone | Fax |
| ACTIVE |
1 WESTROCK LANE PALM COAST, FL 32164 |
386-898-3419 | 386-446-9206 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 01/03/2025 | APPROVED - AS NOTED | GBERTOLA |
| Note: 1/3/25=AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 12/30/24 TPOLACEK*** BUILDER MUST INSTALL A FORM BOARD ALONG ROAD EDGE TO PREVENT CONCRETE FROM ADHEREING TO ASPHALT. THE BUILDER WILL BE REQUIRED TO CUT OUT ASPHALT A MINIMUM OF 12" AWAY FROM DRIVEWAY THE WIDTH OF THE DRIVEWAY AND PREFORM A HOT PATCH REPAIR AFTER CONCRETE IS SET. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ROW - FINAL INSPECTION | 01/03/2025 | APPROVED | GBERTOLA |
| Note: 1/3/25=AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 12/30/24 TPOLACEK*** BUILDER MUST INSTALL A FORM BOARD ALONG ROAD EDGE TO PREVENT CONCRETE FROM ADHEREING TO ASPHALT. THE BUILDER WILL BE REQUIRED TO CUT OUT ASPHALT A MINIMUM OF 12" AWAY FROM DRIVEWAY THE WIDTH OF THE DRIVEWAY AND PREFORM A HOT PATCH REPAIR AFTER CONCRETE IS SET. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/03/2025 | FINAL APPROVED | LFITZGERALD |
| ROW- PRE-APRON (PRE-POUR) | 12/30/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/30/24 TPOLACEK*** BUILDER MUST INSTALL A FORM BOARD ALONG ROAD EDGE TO PREVENT CONCRETE FROM ADHEREING TO ASPHALT. THE BUILDER WILL BE REQUIRED TO CUT OUT ASPHALT A MINIMUM OF 12" AWAY FROM DRIVEWAY THE WIDTH OF THE DRIVEWAY AND PREFORM A HOT PATCH REPAIR AFTER CONCRETE IS SET. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. |
Review History
| Department | Status | Date In | Date Out |
| SWALE | COMPLETE | 12/13/2024 | 12/27/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/12/2024 | 12/13/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 12/12/2024 | 12/18/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/12/2024 | 12/13/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 12/18/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/18/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 12/18/2024 |
| SW ENG PRE APRON | ¤30.00 | 12/18/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/18/2024 |
| SITE PLAN 15 | ¤15.00 | 12/18/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤312.00 |