I want to search for...

Permit #2024120733

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00370-0140
CONDITIONED SPACE: 1867 sqft
GARAGE: 409 sqft
OPENED PORCH (WITH ROOF) : 28 sqft
Total Square Footage: 2304 sqft
Block: 00370
Subdivision: -
Job Phone: 904-268-7730
Location Address: 6 LLEBERRY PATH
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/14/2025
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FOCUS HOMES LLC

Address

5220 SHAD RD

JACKSONVILLE, FL 32257

Lot: 0140
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
ADAM JASON OCONNOR
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13013779 (Exp: 08/31/2026) 407-321-0064 X3432
RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone
ACTIVE

1165 SOUTH 5TH

MACCLENNY, FL 32063

CCC1330709 (Exp: 08/31/2026) 904-322-9409

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/17/2026 FINAL APPROVED KSANDOE
Note: 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: Previously listed 4 remains unresolved. 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Screen has been removed but the Gooseneck is missing a self closing damper as required. A replacement with the correct gooseneck is required. Additional items from Full Inspection. 2). ODU has a broken tapcon that requires replacement. FBC-M1307.1 & FBC-M1307.2 3). AHU closet hole in wall at FLMC conduit needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling and walls need to be sealed with the approved material. FBC EC TABLE R402.4.1.1 / FBC-R302.11(4). 5). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4/10/2026 - PREVIOUS INSPECTION NOTES 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4).
U -UTILITY RESIDENTIAL FINAL 04/17/2026 FINAL APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9035 NO CC / NO IRR
ROW FIELD SURVEY /GRADING CERTIFICATION 04/16/2026 CANCELLED BY INSPECTOR FSLADISH
Note: 4/16/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 4/15/26 FINAL SURVEY NOW SHOWS CULVERT PIPE IN TOLERANCE WITH COPC SWALE DIAGRAM. APPROVING AS NOTED. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE.
ROW - STORMWATER FINAL 04/16/2026 APPROVED FSLADISH
Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 04/16/2026 APPROVED FSLADISH
Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 04/16/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 1:19:15 PM *** 4/16/26: Previously listed 4 remains unresolved. 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Screen has been removed but the Gooseneck is missing a self closing damper as required. A replacement with the correct gooseneck is required. Additional items from Full Inspection. 2). ODU has a broken tapcon that requires replacement. FBC-M1307.1 & FBC-M1307.2 3). AHU closet hole in wall at FLMC conduit needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling and walls need to be sealed with the approved material. FBC EC TABLE R402.4.1.1 / FBC-R302.11(4). 5). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4/10/2026 - PREVIOUS INSPECTION NOTES 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4).
U-CROSS CONNECTION 04/16/2026 APPROVED - AS NOTED TLOWE
Note: NO CC / NO IRR
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/15/2026 APPROVED - AS NOTED FSLADISH
Note: 4/15/26 FINAL SURVEY NOW SHOWS CULVERT PIPE IN TOLERANCE WITH COPC SWALE DIAGRAM. APPROVING AS NOTED. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/13/2026 Disapproved - NO FEE FSLADISH
Note: 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE.
BLD - BUILDING FINAL 04/10/2026 CANCELLED BY APPLICANT KSANDOE
Note: 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4).
BLD - BUILDING FINAL 04/08/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/8/2026 12:43:02 PM *** 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4).
ROW- PRE-APRON (PRE-POUR) 03/19/2026 APPROVED FSLADISH
Note: 3/19/26 MINIMUM REQUIREMENTS MET. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 3/18/2026 - PREVIOUS INSPECTION NOTES THERE ARE AREAS THAT NEED DIRT REMOVED TO GIVE YOU THE MINIMUM AMOUNT OF CONCRETE PLEASE FIX ALL AREAS. -------------------------------------------------------------------------------- 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY.
ROW- PRE-APRON (PRE-POUR) 03/18/2026 Disapproved -FEE REQUIRED PFLANAGAN
Note: THERE ARE AREAS THAT NEED DIRT REMOVED TO GIVE YOU THE MINIMUM AMOUNT OF CONCRETE PLEASE FIX ALL AREAS. -------------------------------------------------------------------------------- 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY.
ROW- PRE-APRON (PRE-POUR) 03/17/2026 CANCELLED BY APPLICANT FSLADISH
Note: 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY.
ROW- PRE-APRON (PRE-POUR) 03/16/2026 CANCELLED BY APPLICANT FSLADISH
Note: 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY.
ELECTRIC - EARLY POWER 03/09/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/9/2026 12:04:17 PM *** 3/9/26: FPL emailed to release power. Inspector Notes from Inspection 2200 1. SPD must be installed by early power Emailed FPL @ 1pm
SEWER TIE IN 03/05/2026 APPROVED KSANDOE
PEP TANK INSTALLATION REQUEST 02/17/2026 APPROVED ISANDERSON
WINDOW NAILING 02/12/2026 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 02/12/2026 APPROVED BTAYLOR
Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1. Can not approve untill windows and exterior doors have been installed to check waterproofing around windows/doors
INSULATION 02/05/2026 APPROVED CVANSTRAHLEN
Note: PLEASE FASTENED THE SLIDDING DOOR PLASTIC
ALL ROUGH 02/04/2026 APPROVED CVANSTRAHLEN
Note: 2/3/2026 - PREVIOUS INSPECTION NOTES Please fastened and secured Metal plate where need it ( laundry room and kitchen sink ) 2/2/2026 - PREVIOUS INSPECTION NOTES Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed
ALL ROUGH 02/03/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fastened and secured Metal plate where need it ( laundry room and kitchen sink ) 2/2/2026 - PREVIOUS INSPECTION NOTES Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed
ALL ROUGH 02/02/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed
ALL ROUGH 01/30/2026 Disapproved -FEE REQUIRED MKRASKI
Note: 1/30/26 1. No E-cals onsite 2. Windows and SGD have not been installed 3. Ufer is outside wall, P-ring needs to be moved to access to ufer 4. N/P required at bottom plate under washer box 5. Support washer box better 6. Slab at tub drain needs to be sealed 7. Low voltage box missing outlet box
LATH/BRICK/ WATER BARRIER 01/30/2026 Disapproved - NO FEE MKRASKI
Note: 1. Can not approve untill windows and exterior doors have been installed to check waterproofing around windows/doors
ELECTRIC-TUG 01/30/2026 APPROVED - AS NOTED MKRASKI
Note: 1. SPD must be installed by early power Emailed FPL @ 1pm
FOUND SURVEY APPROVED (OFFICE) 01/23/2026 APPROVED RRICKS
GRAVITY SEWER TEST 01/23/2026 APPROVED KSANDOE
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 1-22-26 1. Lid is glued on can not see if pipe has water. 1/21/2026 - PREVIOUS INSPECTION NOTES Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
WALL SHEATHING 01/23/2026 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/23/2026 APPROVED BTAYLOR
ROOF VALLEY & METAL 01/23/2026 APPROVED BTAYLOR
GRAVITY SEWER TEST 01/22/2026 Disapproved -FEE REQUIRED BTAYLOR
Note: 1-22-26 1. Lid is glued on can not see if pipe has water. 1/21/2026 - PREVIOUS INSPECTION NOTES Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
GRAVITY SEWER TEST 01/21/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
GRAVITY SEWER TEST 01/20/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
GRAVITY SEWER TEST 01/16/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
GRAVITY SEWER TEST 01/07/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2026 2:18:09 PM *** 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4
MONOLITHIC SLAB 01/07/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2026 1:58:26 PM *** 1/7/26: This inspection was completed on 1/5/26 while Inspection (server) system was down with technical complications.. RS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 12/31/2025 APPROVED PBUCKLEY
PLUMBING 1ST ROUGH UNDERGROUND 12/31/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/31/2025 2:53:17 PM ***
WATER METER INSTALLATION REQUEST 12/22/2025 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 12/17/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 04/14/2026 04/14/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/10/2026 04/13/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs without approval stamp for review
SW1 COMPLETE 01/23/2026 01/23/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/23/2026 01/23/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 01/23/2026 01/23/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM No benchmark on formboard survey.
SW1 COMPLETE 01/23/2026 01/23/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/23/2026 01/23/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 12/31/2025 12/31/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 COMPLETE 12/22/2025 12/22/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 HOLD 12/19/2025 12/19/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM MUST GET THE THE NEAREST FFE OF THE HOUSE TO THE LEFT
SW1 HOLD 12/19/2025 12/19/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Note: Both adjacent homes are under construction by the same builder and proposed FFEs are within COPC Tolerances. - For wood-framed homes there shall be a minimum fall of 0.5' from the FFE at the grade adjacent to the foundation. Currently there is only 0.3'. Please take in consideration 4 Lleberry that has an approved grading plan. See informational attachment.
ENGIN1 COMPLETE 09/11/2025 09/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 09/11/2025 09/18/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 09/11/2025 09/11/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 12/18/2024 01/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 12/17/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/17/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 12/17/2024 12/17/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/17/2024 12/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/17/2024 12/18/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 12/17/2024 12/19/2024
LOCATE COMPLETE 12/17/2024 12/18/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 12/17/2024 12/20/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/17/2024 12/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector’s approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD.
ZON COMPLETE 12/17/2024 12/18/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 04/17/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00 04/16/2026
RSI REINSPECTION 1 ¤35.00 04/16/2026
ADMINISTRATIVE - EXTENSION ¤40.00 04/16/2026
EXTENSION ¤40.00 04/16/2026
PLAN REVIEW - REVISION ¤32.50 04/16/2026
INSPECTION - RESIDENTIAL ¤937.75 01/14/2025
PLAN REVIEW - RESIDENTIAL ¤265.98 01/14/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/14/2025
WATER- TURN ON ¤25.00 01/14/2025
ADJUSTMENT 10% (¤123.37) 01/14/2025
SURCHARGE FS 533.721 ¤11.10 01/14/2025
SURCHARGE - FS 468.631 ¤16.66 01/14/2025
SW ENG - FOUNDATION SURVEY ¤20.00 01/14/2025
SW ENG INSPECTION 80 ¤80.00 01/14/2025
SW ENG PRE APRON ¤30.00 01/14/2025
SW ENG - REVIEW 20 ¤20.00 01/14/2025
SW ENG RES REVIEW 200 ¤200.00 01/14/2025
SEWER INSPECTION (¤25.00) 01/14/2025
SEWER INSPECTION ¤25.00 01/14/2025
SEWER CAPITAL FACILITY (¤3,030.00) 01/14/2025
SEWER CAPITAL FACILITY ¤6,120.52 01/14/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 01/14/2025
WATER CAPITAL FACILITY FEE (¤2,160.00) 01/14/2025
SITE PLAN 30 ¤30.00 01/14/2025
CONNECTION FEES (¤750.00) 01/14/2025
CONNECTION FEES ¤1,187.26 01/14/2025
CONTRACTOR CHANGE ¤20.00 01/14/2025
FC IMPACT FEE EMS ¤62.00 01/14/2025
IMPACT FEE FIRE ¤434.51 01/14/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/14/2025
FC IMPACT FEE LIBRARY ¤268.00 01/14/2025
IMPACT FEE PARKS ¤1,828.01 01/14/2025
IMPACT FEE SCHOOL ¤5,450.00 01/14/2025
IMPACT FEE TRANSPORTATION ¤1,862.00 01/14/2025
WATER -IRRIGATION INSPECTION ¤25.00 01/14/2025
Fees Total Due: ¤0.00 Total Paid: ¤17,977.06