I want to search for...
Permit #2024120733
Permit Details
Status: COED
| Parcel Id: 07-11-31-7064-00370-0140 |
| CONDITIONED SPACE: 1867 sqft |
| GARAGE: 409 sqft |
| OPENED PORCH (WITH ROOF) : 28 sqft |
| Total Square Footage: 2304 sqft |
| Block: 00370 |
| Subdivision: - |
| Job Phone: 904-268-7730 |
| Location Address: 6 LLEBERRY PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/14/2025 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
ADAM JASON OCONNOR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13013779 (Exp: 08/31/2026) | 407-321-0064 X3432 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1165 SOUTH 5TH MACCLENNY, FL 32063 |
CCC1330709 (Exp: 08/31/2026) | 904-322-9409 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/17/2026 | FINAL APPROVED | KSANDOE |
| Note: 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: Previously listed 4 remains unresolved. 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Screen has been removed but the Gooseneck is missing a self closing damper as required. A replacement with the correct gooseneck is required. Additional items from Full Inspection. 2). ODU has a broken tapcon that requires replacement. FBC-M1307.1 & FBC-M1307.2 3). AHU closet hole in wall at FLMC conduit needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling and walls need to be sealed with the approved material. FBC EC TABLE R402.4.1.1 / FBC-R302.11(4). 5). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4/10/2026 - PREVIOUS INSPECTION NOTES 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). | |||
| U -UTILITY RESIDENTIAL FINAL | 04/17/2026 | FINAL APPROVED | TPOLACEK |
| Note: Inspector Notes from Inspection 9035 NO CC / NO IRR | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/16/2026 | CANCELLED BY INSPECTOR | FSLADISH |
| Note: 4/16/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 4/15/26 FINAL SURVEY NOW SHOWS CULVERT PIPE IN TOLERANCE WITH COPC SWALE DIAGRAM. APPROVING AS NOTED. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE. | |||
| ROW - STORMWATER FINAL | 04/16/2026 | APPROVED | FSLADISH |
| Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 04/16/2026 | APPROVED | FSLADISH |
| Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| BLD - BUILDING FINAL | 04/16/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/16/2026 1:19:15 PM *** 4/16/26: Previously listed 4 remains unresolved. 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 Screen has been removed but the Gooseneck is missing a self closing damper as required. A replacement with the correct gooseneck is required. Additional items from Full Inspection. 2). ODU has a broken tapcon that requires replacement. FBC-M1307.1 & FBC-M1307.2 3). AHU closet hole in wall at FLMC conduit needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling and walls need to be sealed with the approved material. FBC EC TABLE R402.4.1.1 / FBC-R302.11(4). 5). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4/10/2026 - PREVIOUS INSPECTION NOTES 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). | |||
| U-CROSS CONNECTION | 04/16/2026 | APPROVED - AS NOTED | TLOWE |
| Note: NO CC / NO IRR | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/15/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/15/26 FINAL SURVEY NOW SHOWS CULVERT PIPE IN TOLERANCE WITH COPC SWALE DIAGRAM. APPROVING AS NOTED. BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/13/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 4/13/26 YOUR CULVERT PIPE IS OUT OF TOLERANCE TO THE COPC SWALE PLAN DIAGRAM. SEE PHOTO FOR REFERENCE. | |||
| BLD - BUILDING FINAL | 04/10/2026 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). | |||
| BLD - BUILDING FINAL | 04/08/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/8/2026 12:43:02 PM *** 4/8/26: Incomplete inspection due to painters still working throughout the entire house. Partial List: Smokes only checked and approved. 1). No hot water. ( breaker off upon arrival). FBCR P2722.2 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). 1 of 3 locking caps on ODU is not locked. FBCR M1411.8 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). | |||
| ROW- PRE-APRON (PRE-POUR) | 03/19/2026 | APPROVED | FSLADISH |
| Note: 3/19/26 MINIMUM REQUIREMENTS MET. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 3/18/2026 - PREVIOUS INSPECTION NOTES THERE ARE AREAS THAT NEED DIRT REMOVED TO GIVE YOU THE MINIMUM AMOUNT OF CONCRETE PLEASE FIX ALL AREAS. -------------------------------------------------------------------------------- 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/18/2026 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THERE ARE AREAS THAT NEED DIRT REMOVED TO GIVE YOU THE MINIMUM AMOUNT OF CONCRETE PLEASE FIX ALL AREAS. -------------------------------------------------------------------------------- 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/17/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/16/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ELECTRIC - EARLY POWER | 03/09/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/9/2026 12:04:17 PM *** 3/9/26: FPL emailed to release power. Inspector Notes from Inspection 2200 1. SPD must be installed by early power Emailed FPL @ 1pm | |||
| SEWER TIE IN | 03/05/2026 | APPROVED | KSANDOE |
| PEP TANK INSTALLATION REQUEST | 02/17/2026 | APPROVED | ISANDERSON |
| WINDOW NAILING | 02/12/2026 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 02/12/2026 | APPROVED | BTAYLOR |
| Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1. Can not approve untill windows and exterior doors have been installed to check waterproofing around windows/doors | |||
| INSULATION | 02/05/2026 | APPROVED | CVANSTRAHLEN |
| Note: PLEASE FASTENED THE SLIDDING DOOR PLASTIC | |||
| ALL ROUGH | 02/04/2026 | APPROVED | CVANSTRAHLEN |
| Note: 2/3/2026 - PREVIOUS INSPECTION NOTES Please fastened and secured Metal plate where need it ( laundry room and kitchen sink ) 2/2/2026 - PREVIOUS INSPECTION NOTES Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed | |||
| ALL ROUGH | 02/03/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fastened and secured Metal plate where need it ( laundry room and kitchen sink ) 2/2/2026 - PREVIOUS INSPECTION NOTES Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed | |||
| ALL ROUGH | 02/02/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 1/30/2026 - PREVIOUS INSPECTION NOTES 1/30/ 2. Windows and SGD have not been installed | |||
| ALL ROUGH | 01/30/2026 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1/30/26 1. No E-cals onsite 2. Windows and SGD have not been installed 3. Ufer is outside wall, P-ring needs to be moved to access to ufer 4. N/P required at bottom plate under washer box 5. Support washer box better 6. Slab at tub drain needs to be sealed 7. Low voltage box missing outlet box | |||
| LATH/BRICK/ WATER BARRIER | 01/30/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Can not approve untill windows and exterior doors have been installed to check waterproofing around windows/doors | |||
| ELECTRIC-TUG | 01/30/2026 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. SPD must be installed by early power Emailed FPL @ 1pm | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/23/2026 | APPROVED | RRICKS |
| GRAVITY SEWER TEST | 01/23/2026 | APPROVED | KSANDOE |
| Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 1-22-26 1. Lid is glued on can not see if pipe has water. 1/21/2026 - PREVIOUS INSPECTION NOTES Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| WALL SHEATHING | 01/23/2026 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/23/2026 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 01/23/2026 | APPROVED | BTAYLOR |
| GRAVITY SEWER TEST | 01/22/2026 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 1-22-26 1. Lid is glued on can not see if pipe has water. 1/21/2026 - PREVIOUS INSPECTION NOTES Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| GRAVITY SEWER TEST | 01/21/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Not water on drain pipe ( need to filled pipe with water ) 1/20/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| GRAVITY SEWER TEST | 01/20/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items from previous inspection 1/16/2026 - PREVIOUS INSPECTION NOTES 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| GRAVITY SEWER TEST | 01/16/2026 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 1/16/26 Previous notes not rectified 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| GRAVITY SEWER TEST | 01/07/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/7/2026 2:18:09 PM *** 1/7/26: 1). Entire drain is covered with backfill. Could not inspect. FBC[A]110.1 / FRBC-P3005.3 2). Also head pressure is not holding. Pipe needs to be filled to the top and stay ther for the inspection. FRBC-P2503.4 | |||
| MONOLITHIC SLAB | 01/07/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/7/2026 1:58:26 PM *** 1/7/26: This inspection was completed on 1/5/26 while Inspection (server) system was down with technical complications.. RS | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 12/31/2025 | APPROVED | PBUCKLEY |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/31/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/31/2025 2:53:17 PM *** | |||
| WATER METER INSTALLATION REQUEST | 12/22/2025 | CANCELLED BY APPLICANT | WEB |
| WATER METER INSTALLATION REQUEST | 12/17/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/14/2026 | 04/14/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/10/2026 | 04/13/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs without approval stamp for review | |||
| SW1 | COMPLETE | 01/23/2026 | 01/23/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/23/2026 | 01/23/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/23/2026 | 01/23/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM No benchmark on formboard survey. | |||
| SW1 | COMPLETE | 01/23/2026 | 01/23/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/23/2026 | 01/23/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/31/2025 | 12/31/2025 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/22/2025 | 12/22/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/19/2025 | 12/19/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM MUST GET THE THE NEAREST FFE OF THE HOUSE TO THE LEFT | |||
| SW1 | HOLD | 12/19/2025 | 12/19/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Note: Both adjacent homes are under construction by the same builder and proposed FFEs are within COPC Tolerances. - For wood-framed homes there shall be a minimum fall of 0.5' from the FFE at the grade adjacent to the foundation. Currently there is only 0.3'. Please take in consideration 4 Lleberry that has an approved grading plan. See informational attachment. | |||
| ENGIN1 | COMPLETE | 09/11/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/11/2025 | 09/18/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/11/2025 | 09/11/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/18/2024 | 01/06/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 12/17/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/17/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/17/2024 | 12/17/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/17/2024 | 12/23/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/17/2024 | 12/18/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/17/2024 | 12/19/2024 |
| LOCATE | COMPLETE | 12/17/2024 | 12/18/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/17/2024 | 12/20/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/17/2024 | 12/20/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector’s approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD. | |||
| ZON | COMPLETE | 12/17/2024 | 12/18/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/17/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 04/16/2026 |
| ADMINISTRATIVE - EXTENSION | ¤40.00 | 04/16/2026 |
| EXTENSION | ¤40.00 | 04/16/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/16/2026 |
| INSPECTION - RESIDENTIAL | ¤937.75 | 01/14/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤265.98 | 01/14/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/14/2025 |
| WATER- TURN ON | ¤25.00 | 01/14/2025 |
| ADJUSTMENT 10% | (¤123.37) | 01/14/2025 |
| SURCHARGE FS 533.721 | ¤11.10 | 01/14/2025 |
| SURCHARGE - FS 468.631 | ¤16.66 | 01/14/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/14/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/14/2025 |
| SW ENG PRE APRON | ¤30.00 | 01/14/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/14/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/14/2025 |
| SEWER INSPECTION | (¤25.00) | 01/14/2025 |
| SEWER INSPECTION | ¤25.00 | 01/14/2025 |
| SEWER CAPITAL FACILITY | (¤3,030.00) | 01/14/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 01/14/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 01/14/2025 |
| WATER CAPITAL FACILITY FEE | (¤2,160.00) | 01/14/2025 |
| SITE PLAN 30 | ¤30.00 | 01/14/2025 |
| CONNECTION FEES | (¤750.00) | 01/14/2025 |
| CONNECTION FEES | ¤1,187.26 | 01/14/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 01/14/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 01/14/2025 |
| IMPACT FEE FIRE | ¤434.51 | 01/14/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/14/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/14/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 01/14/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/14/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 01/14/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/14/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,977.06 |