Permit #2024120869
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7019-00210-0120 |
| GARAGE: 480 sqft |
| CONDITIONED SPACE: 1600 sqft |
| OPENED PORCH (WITH ROOF) : 370 sqft |
| Total Square Footage: 2450 sqft |
| Block: 00210 |
| Subdivision: 7019 - |
| Job Phone: 386-237-5837 |
| Location Address: 9 WATKINS PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/30/2025 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: KORS HOME LLC |
|
Address 42 WHITE DOVE LANE PALM COAST, FL 32164 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single Family residence |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
MARSEL GILMANSHIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
SERGEY A VORONIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7631 SEVERN JACKSONVILLE, FL 32224 |
EC13011326 (Exp: 08/31/2026) | 360-798-2819 |
ANDREY GORZDEV
| Status | Location Address | State License Number | Phone |
| ACTIVE |
12278 PEANUT CT JACKSONVILLE, FL 32226 |
CAC1823458 (Exp: 08/31/2026) | 904-574-1000 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 04/09/2026 | APPROVED | TLOWE |
| Note: 11/7/2025 - PREVIOUS INSPECTION NOTES 10/6/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 no irr-no cc Sewer cleanout need to be cut to grade. Sewer cleanout needs to be cut and lowered to grade. | |||
| ROW - STORMWATER FINAL | 12/09/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 12/5/2025 - PREVIOUS INSPECTION NOTES ** 12/05/25 BUILDER NEEDS TO BUILD UP THE BERM TO MATCH FROM THE REAR TO FRONT ALONG RIGHT SIDE AS THE BERM GOES FLAT MID-WAY NEEDS TO BE RAISED SO YOUR WATER DOES NOT NEGATIVELY IMPACT THE ADJACENT PROPERTY OF THE FLAG LOT NOTE PINK PAINT _______________________________________________________________________________________________________________________ 12/4/2025 - PREVIOUS INSPECTION NOTES 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK*** BUILDER STILL HAS SMALL CORRECTION TO MAKE AND ASKED TO PLEASE CANCEL FOR TODAY 11/5/2025 - PREVIOUS INSPECTION NOTES 11-05-25 TPOLACEK*** BACK SODE OF STRUCTURE ALONG ADJACENT PROPERTY OF FLAG LOT THERE NEEDS TO BE A INSIDE SWALE OF .30 FROM TIP TO TOE AS TO NOT NEGATIVLY IMPACT ADJACENT PROPERTY Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/05/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 12/05/25 BUILDER NEEDS TO BUILD UP THE BERM TO MATCH FROM THE REAR TO FRONT ALONG RIGHT SIDE AS THE BERM GOES FLAT MID-WAY NEEDS TO BE RAISED SO YOUR WATER DOES NOT NEGATIVELY IMPACT THE ADJACENT PROPERTY OF THE FLAG LOT NOTE PINK PAINT _______________________________________________________________________________________________________________________ 12/4/2025 - PREVIOUS INSPECTION NOTES 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK*** BUILDER STILL HAS SMALL CORRECTION TO MAKE AND ASKED TO PLEASE CANCEL FOR TODAY 11/5/2025 - PREVIOUS INSPECTION NOTES 11-05-25 TPOLACEK*** BACK SODE OF STRUCTURE ALONG ADJACENT PROPERTY OF FLAG LOT THERE NEEDS TO BE A INSIDE SWALE OF .30 FROM TIP TO TOE AS TO NOT NEGATIVLY IMPACT ADJACENT PROPERTY Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/04/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK*** BUILDER STILL HAS SMALL CORRECTION TO MAKE AND ASKED TO PLEASE CANCEL FOR TODAY 11/5/2025 - PREVIOUS INSPECTION NOTES 11-05-25 TPOLACEK*** BACK SODE OF STRUCTURE ALONG ADJACENT PROPERTY OF FLAG LOT THERE NEEDS TO BE A INSIDE SWALE OF .30 FROM TIP TO TOE AS TO NOT NEGATIVLY IMPACT ADJACENT PROPERTY Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/02/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 12-2-25 TPOLACEK*** BUILDER STILL HAS SMALL CORRECTION TO MAKE AND ASKED TO PLEASE CANCEL FOR TODAY 11/5/2025 - PREVIOUS INSPECTION NOTES 11-05-25 TPOLACEK*** BACK SODE OF STRUCTURE ALONG ADJACENT PROPERTY OF FLAG LOT THERE NEEDS TO BE A INSIDE SWALE OF .30 FROM TIP TO TOE AS TO NOT NEGATIVLY IMPACT ADJACENT PROPERTY Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 11/07/2025 | Disapproved - NO FEE | BHAINES |
| Note: 10/6/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 no irr-no cc Sewer cleanout need to be cut to grade. Sewer cleanout needs to be cut and lowered to grade. | |||
| BLD - BUILDING FINAL | 11/07/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 11/7/25 1. No plans on site FBC 107.3.1 2. E-cals do not match equipment installed FBC M1401.3 3. Register grill for master bedroom duct jumper missing FBCR M1601.4.1 4. W/p cover required fot ufer ground access FBC EC R402.4.1.1 5. Sewer not hooked up N.E. side of home connection not made (keep exposed for re-inspection) FBCR P2903.8.5 6. Seal AHU whip at garage ceiling penitration FBC R302.6 Make ALL repairs before next inspection 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 | |||
| ROW - FINAL APRON (AFTER POUR) | 11/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 11/05/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-05-25 TPOLACEK*** BACK SODE OF STRUCTURE ALONG ADJACENT PROPERTY OF FLAG LOT THERE NEEDS TO BE A INSIDE SWALE OF .30 FROM TIP TO TOE AS TO NOT NEGATIVLY IMPACT ADJACENT PROPERTY Inspector Notes from Inspection 9465 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 11/05/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: via text 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 | |||
| GRAVITY SEWER TEST | 10/06/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2095 Inspector Notes from Inspection 2060 2/12/2025 - PREVIOUS INSPECTION NOTES ALL WATER PIPING WAS REMOVED FROM SLAB AND REPLACED WITH NEW DUE TO AGE OF PERMIT AND EXSPOSURE TO SUN AND ''UV RAYS FROM SUN LIGHT''. REMOVE ALL VEGITATION FROM FOOTER AREAS AND STEEL THAT HAS RUST Inspector Notes from Inspection 2060 2/12/2025 - PREVIOUS INSPECTION NOTES ALL WATER PIPING WAS REMOVED FROM SLAB AND REPLACED WITH NEW DUE TO AGE OF PERMIT AND EXSPOSURE TO SUN AND ''UV RAYS FROM SUN LIGHT''. REMOVE ALL VEGITATION FROM FOOTER AREAS AND STEEL THAT HAS RUST THIS WAS A VIRTUAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 10/06/2025 | Disapproved - NO FEE | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 no irr-no cc Sewer cleanout need to be cut to grade. | |||
| U-CROSS CONNECTION | 09/25/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/05/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/05/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 09-05-25 TPOLACEK*** PLEASE HAVE PROPERTY MOWED BEFORE FINAL ROW APPROVING FIELD AS NOTED. RIGHT SIDE SEEMS OK BUT CANNOT SEE FULL GRADE WITH TALL GRASS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 08/20/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 12:10pm | |||
| ROW- PRE-APRON (PRE-POUR) | 07/18/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| SEWER TIE IN | 06/24/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 2/12/2025 - PREVIOUS INSPECTION NOTES ALL WATER PIPING WAS REMOVED FROM SLAB AND REPLACED WITH NEW DUE TO AGE OF PERMIT AND EXSPOSURE TO SUN AND ''UV RAYS FROM SUN LIGHT''. REMOVE ALL VEGITATION FROM FOOTER AREAS AND STEEL THAT HAS RUST Inspector Notes from Inspection 2060 2/12/2025 - PREVIOUS INSPECTION NOTES ALL WATER PIPING WAS REMOVED FROM SLAB AND REPLACED WITH NEW DUE TO AGE OF PERMIT AND EXSPOSURE TO SUN AND ''UV RAYS FROM SUN LIGHT''. REMOVE ALL VEGITATION FROM FOOTER AREAS AND STEEL THAT HAS RUST THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 06/06/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 | |||
| LATH/BRICK/ WATER BARRIER | 06/05/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 6/5/25 Via super in person 6/4/25 Via text 6/3/25 1. Seal all exterior penitrations and holes in block FBC EC R402.4.1.1 2. Water barrier and flashing missing around windows and door FBC R703.4 (1) 3. Repair silt fence to orginal conditon FBC 3307.1 4. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 Inspector Notes from Inspection 2420 5/15/25 1. Please revise duct layout to show duct for entry way FBC(A) 107.4 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| LATH/BRICK/ WATER BARRIER | 06/04/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 6/4/25 Via text 6/3/25 1. Seal all exterior penitrations and holes in block FBC EC R402.4.1.1 2. Water barrier and flashing missing around windows and door FBC R703.4 (1) 3. Repair silt fence to orginal conditon FBC 3307.1 4. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 Inspector Notes from Inspection 2420 5/15/25 1. Please revise duct layout to show duct for entry way FBC(A) 107.4 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| LATH/BRICK/ WATER BARRIER | 06/03/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 6/3/25 1. Seal all exterior penitrations and holes in block FBC EC R402.4.1.1 2. Water barrier and flashing missing around windows and door FBC R703.4 (1) 3. Repair silt fence to orginal conditon FBC 3307.1 4. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 Inspector Notes from Inspection 2420 5/15/25 1. Please revise duct layout to show duct for entry way FBC(A) 107.4 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| INSULATION | 05/19/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 Inspector Notes from Inspection 2420 5/15/25 1. Please revise duct layout to show duct for entry way FBC(A) 107.4 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| ALL ROUGH | 05/15/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/15/25 1. Please revise duct layout to show duct for entry way FBC(A) 107.4 5/14/2025 - PREVIOUS INSPECTION NOTES 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| ALL ROUGH | 05/14/2025 | CANCELLED BY APPLICANT | MCONTRYMAN |
| Note: 5/14/25 1. Product approvals and energy calcs are not on site FBC(A) 107.3.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/24/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Roof sheathing / breaces and ties down cell was never approveed on prevoius inspections , can't not install roof shingles untill inspection is fully approved or approved as noted 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 1. Make all repairs from [revious imspection before calling in for re-inspection FBC (A)107.4 2. All plans, engineering, revisions shall be on site for inspector and must have stamp of approval from Building Dept. FBC 107.3.1 4/15/2025 1. Trusslayout does not match mitek paperwork 2. All truss to wood connections must be MTS 12s per plans 3. Loading bearing wall not per detail 4. 3 wet set simpson straps missing on lani wall ***Not read a full reinspection will be required, roof sheathing good ok to single after roof valley metal inspection has been passed*** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/24/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/22/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 4/22/25 1. Make all repairs from [revious imspection before calling in for re-inspection FBC (A)107.4 2. All plans, engineering, revisions shall be on site for inspector and must have stamp of approval from Building Dept. FBC 107.3.1 4/15/2025 1. Trusslayout does not match mitek paperwork 2. All truss to wood connections must be MTS 12s per plans 3. Loading bearing wall not per detail 4. 3 wet set simpson straps missing on lani wall ***Not read a full reinspection will be required, roof sheathing good ok to single after roof valley metal inspection has been passed*** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/15/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Trusslayout does not match mitek paperwork 2. All truss to wood connections must be MTS 12s per plans 3. Loading bearing wall not per detail 4. 3 wet set simpson straps missing on lani wall ***Not read a full reinspection will be required, roof sheathing good ok to single after roof valley metal inspection has been passed*** | |||
| ROOF VALLEY & METAL | 04/14/2025 | APPROVED | MKRASKI |
| ROOF VALLEY & METAL | 04/11/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Via super phone call Inspector Notes from Inspection 2450 3/31/25 1. Dump trailer on site but site not cleaned up, Please clean up site by next inspection to avoid fees FBC 3302.2 | |||
| ROOF VALLEY & METAL | 04/02/2025 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2450 3/31/25 1. Dump trailer on site but site not cleaned up, Please clean up site by next inspection to avoid fees FBC 3302.2 | |||
| WALL SHEATHING | 03/31/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 3/31/25 1. Dump trailer on site but site not cleaned up, Please clean up site by next inspection to avoid fees FBC 3302.2 | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/28/2025 | APPROVED | RRICKS |
| TIE BEAM / LINTEL | 03/17/2025 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 02/28/2025 | APPROVED | MCONTRYMAN |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/19/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: 2/12/2025 - PREVIOUS INSPECTION NOTES ALL WATER PIPING WAS REMOVED FROM SLAB AND REPLACED WITH NEW DUE TO AGE OF PERMIT AND EXSPOSURE TO SUN AND ''UV RAYS FROM SUN LIGHT''. REMOVE ALL VEGITATION FROM FOOTER AREAS AND STEEL THAT HAS RUST | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/12/2025 | CANCELLED BY APPLICANT | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 02/11/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 02/03/2025 | APPROVED | CBOWERMASTER |
| BLD - BUILDING FINAL | |||
| Note: 11/7/2025 - PREVIOUS INSPECTION NOTES 11/7/25 1. No plans on site FBC 107.3.1 2. E-cals do not match equipment installed FBC M1401.3 3. Register grill for master bedroom duct jumper missing FBCR M1601.4.1 4. W/p cover required fot ufer ground access FBC EC R402.4.1.1 5. Sewer not hooked up N.E. side of home connection not made (keep exposed for re-inspection) FBCR P2903.8.5 6. Seal AHU whip at garage ceiling penitration FBC R302.6 Make ALL repairs before next inspection 5/19/25 1. Please revise, and have city approved, duct layout to show duct for entry way by final to avoid failure and fees FBC(A) 107.4 |
Review History
| Department | Status | Date In | Date Out |
| MECH | HOLD | 11/14/2025 | 11/18/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| MECH | COMPLETE | 11/05/2025 | 11/06/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/21/2025 | 04/22/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/11/2025 | 04/14/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/08/2025 | 04/10/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM The truss layout from the truss manufacturer needs to be stmped and approved by engineer on record. Not the teuss layout in the plans. They are two different plans that need to match. | |||
| BLD | HOLD | 04/01/2025 | 04/04/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| ENGIN1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/06/2025 | 02/11/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/04/2025 | 02/04/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/31/2025 | 01/31/2025 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM NOC needs to be in KORS Home LLC as owner | |||
| ENGIN1 | COMPLETE | 01/24/2025 | 01/28/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/24/2025 | 01/28/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/24/2025 | 01/24/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/14/2025 | 01/14/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan repeat comment 1.Second map panel number is missing should be 0138E & 0136E 2.walkway to entry of home not provided Please show the width of the walkway to the home. Please know that it can not be wider that 6 ft. 3.Elevation sheet: Elevation page:Right and left are labeled incorrectly please adjust the plan accordingly and also show the the right side corner will wrap around the house for 2 '. | |||
| MECH | COMPLETE | 01/14/2025 | 01/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/14/2025 | 01/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/14/2025 | 01/21/2025 |
| Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/23/2024 | 01/07/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Fl product approval number Fl 742-R10 is expired 2. Fl product approval number Fl 1999-R7 is expired | |||
| CUSVC | COMPLETE | 12/20/2024 | 12/20/2024 |
| Note: Released By: PAMELA MILLER - - FEES PAID ON PREVIOUS PERMIT | |||
| ELEC | HOLD | 12/20/2024 | 12/31/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry, exterior, and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit electrical load calcs 5. Load calcs need to include pool equipment | |||
| ENGIN1 | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/20/2024 | 12/23/2024 |
| LOCATE | COMPLETE | 12/20/2024 | 12/30/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/20/2024 | 12/23/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. State card is one page with the preparers signature on it. Upload this page only and name file state card 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition | |||
| SW1 | HOLD | 12/20/2024 | 12/30/2024 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Side yard "W" swales shall be a minimum of 0.3’ from toe of slope to the top of berm. Please revise the right property line to match this criteria. | |||
| ZON | HOLD | 12/20/2024 | 12/20/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM 1.Please demonstrate that you have 20 in front of the garage area on site plan. Site plan should list two map panel number 0138 Eand 0136E. 16 ft min: 2.Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet. 2.Please show the width of the walkway to the home. Please know that it can not be wider that 6 ft. 3. Elevation page:Right and left are labeled incorrectly please adjust the plan accordingly and also show the the right side corner will wrap around the house for 2 '. Site plan should list two map panel number 0138 Eand 0136E. | |||
| MECH | PENDING |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SURCHARGE FS 533.721 | ¤10.53 | 01/30/2025 |
| SURCHARGE - FS 468.631 | ¤15.80 | 01/30/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/30/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/30/2025 |
| SW ENG PRE APRON | ¤30.00 | 01/30/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/30/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/30/2025 |
| SITE PLAN 30 | ¤30.00 | 01/30/2025 |
| ADJUSTMENT 10% | (¤117.02) | 01/30/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/30/2025 |
| INSPECTION - RESIDENTIAL | ¤888.25 | 01/30/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤251.94 | 01/30/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤1,459.50 |