I want to search for...
Permit #2024120890
Permit Details
Status: COED
| Parcel Id: 06-12-31-5180-00000-0410 |
| CONDITIONED SPACE: 2403 sqft |
| GARAGE: 424 sqft |
| OPENED PORCH (WITH ROOF) : 217 sqft |
| Total Square Footage: 3044 sqft |
| Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1 |
| Job Phone: 904-669-7000 |
| Location Address: 36 MAHOGANY WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/29/2025 |
| NOC: RECORDED |
| Applicant name: PAUL GILBERT AXTELL |
| Owner: TOLL SOUTHEAST LP CO INC |
|
Address 1140 VIRGINIA DRIVE FORT WASHINGTON, PA 19034 |
| Lot: 41 |
| Contracted Stated Job Value: ¤443,759.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
TOLL BROS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
40 EVEREST LN, STE 5 ST JOHNS, FL 32259 |
CGC60445 (Exp: 08/31/2026) | 904-217-3852 |
Sub Contractors
JAMES F QUINN III
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3210 SW 40TH BLVD STE F GAINESVILLE, FL 32608 |
EC13010994 (Exp: 08/31/2026) | 352-378-9274 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
HARLEY M BRYAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5223 EDGEWOOD CT ORMOND BEACH, FL 32174 |
LI26657 (Exp: 08/31/2028) | 386-463-2700 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/24/2025 | FINAL APPROVED | BTAYLOR |
| Note: 7/23/2025 - PREVIOUS INSPECTION NOTES 7/23/25 1. Double oven not installed. Need locking breaker in panel box NEC 422.31 & 110.25 7/22/2025 - PREVIOUS INSPECTION NOTES 1. Arrived at 2:30 and the house was all locked up. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS | |||
| BLD - BUILDING FINAL | 07/23/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 7/23/25 1. Double oven not installed. Need locking breaker in panel box NEC 422.31 & 110.25 7/22/2025 - PREVIOUS INSPECTION NOTES 1. Arrived at 2:30 and the house was all locked up. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS | |||
| BLD - BUILDING FINAL | 07/22/2025 | Disapproved -FEE REQUIRED | HCAMACHO |
| Note: 1. Arrived at 2:30 and the house was all locked up. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS | |||
| U -UTILITY RESIDENTIAL FINAL | 07/01/2025 | FINAL APPROVED | LFITZGERALD |
| Note: 6/27/2025 - PREVIOUS INSPECTION NOTES lower both sewer clean outs | |||
| ROW - STORMWATER FINAL | 06/27/2025 | APPROVED | FSLADISH |
| Note: 6/27/25 AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 06/27/2025 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: lower both sewer clean outs | |||
| ROW - FINAL APRON (AFTER POUR) | 06/27/2025 | APPROVED | FSLADISH |
| Note: 6/27/25 AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/25/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/25/25 YOU DO NOT SHOW REQIRED 6" OF FALL OF STRUCTURE WITHIN THE FIRST 10 FT. BUT YOU ARE SHOWING CONTINUAL FALL TO THE REAR. I WILL DETERMINE ON THE FIELD SURVEY IF THIS IS AN ANOMALY OR IF DRAINAGE WILL HAVE POSITIVE RWAR FALL. APPROVING THIS SURVEY AS NOTED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/25/2025 | APPROVED | FSLADISH |
| Note: 6/25/25 UPON WALKING PROPERTY DETERMINED THERE IS POSITIVE DRAINAGE FALL IN THE REAR OF STRUCTURE AT THE TIME OF THIS INSPECTION. ***INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREAS IN THE REAR OF PROPERTY. YOU WILL ALSO NEED TO INSTALL SILT FENCE ON THE LEFT SIDE PROPERTY LINE, SOD AND STABILIZE RUNOFF IN REAR PAST PROPERTY LINE BEFORE ROW FINAL PASSAGE.*** Inspector Notes from Inspection 9463 6/25/25 YOU DO NOT SHOW REQIRED 6" OF FALL OF STRUCTURE WITHIN THE FIRST 10 FT. BUT YOU ARE SHOWING CONTINUAL FALL TO THE REAR. I WILL DETERMINE ON THE FIELD SURVEY IF THIS IS AN ANOMALY OR IF DRAINAGE WILL HAVE POSITIVE RWAR FALL. APPROVING THIS SURVEY AS NOTED. | |||
| U-CROSS CONNECTION | 06/20/2025 | APPROVED | DHANEY |
| Note: *** NOTES ADDED BY DHANEY 6/20/2025 8:06:16 AM *** No illegal hose cn's No CC . | |||
| ROW- PRE-APRON (PRE-POUR) | 06/09/2025 | APPROVED | FSLADISH |
| Note: 6/9/25 REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ELECTRIC - EARLY POWER | 05/29/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/29/25 Okay to release e-mail to FPL Inspector Notes from Inspection 2200 4/22/25 Okay to release e-mail to FPL Inspector Notes from Inspection 2200 4/22/25 Okay to release e-mail to FPL | |||
| ELECTRIC-TUG | 04/22/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/22/25 Okay to release e-mail to FPL | |||
| GRAVITY SEWER TEST | 04/22/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 04/22/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 04/21/2025 | APPROVED | PKNAPIK |
| Note: Inspector Notes from Inspection 2320 4/16/25 1. CM states that starter strip is zip taped for proper sheathing-to-foundation seal 4/16/2025 - PREVIOUS INSPECTION NOTES 4/16/25 1. Zip tape missing along the sheathing-to-foundation per manufacturers specifications Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| LATH/BRICK/ WATER BARRIER | 04/16/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 4/16/25 1. Zip tape missing along the sheathing-to-foundation per manufacturers specifications Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| LATH/BRICK/ WATER BARRIER | 04/16/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/16/25 1. CM states that starter strip is zip taped for proper sheathing-to-foundation seal 4/16/2025 - PREVIOUS INSPECTION NOTES 4/16/25 1. Zip tape missing along the sheathing-to-foundation per manufacturers specifications Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 Inspector Notes from Inspection 2420 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| WATER METER INSTALLATION REQUEST | 04/11/2025 | APPROVED | CBOWERMASTER |
| ALL ROUGH | 04/10/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/10/25 Will check at Insulation Inspection 1. Will need revision for duct work only, showing what is installed. CM said the 2 missing ducts, on second floor, will also be added. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| ALL ROUGH | 04/09/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 4/3/2025 - PREVIOUS INSPECTION NOTES 4/9/25 1. Missing nail plate on left side of garage door framing FBCR 2603.2.1/NEC 300.4 2. Duct Layout does not match what is installed (highlighted) FBC(A) 107.4 3. Duct on 2nd floor needs clearance from electrical lighting fixture 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| LATH/BRICK/ WATER BARRIER | 04/09/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 4/3/2025 - PREVIOUS INSPECTION NOTES 4/3/25 1. Missing zip tape along bottom edge of zip boards, to foundation, per manufacturers specifications 2. Please install missing zip board pieces and ensure they are properly taped off | |||
| LATH/BRICK/ WATER BARRIER | 04/03/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 4/3/25 1. Missing zip tape along bottom edge of zip boards, to foundation, per manufacturers specifications 2. Please install missing zip board pieces and ensure they are properly taped off | |||
| ALL ROUGH | 04/03/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 4/3/25 1. No energy calcs on site FBC(A) 107.3.1 2. Window in upstairs bedroom is not installed 3. Missing nail plates for drain line in downstair fron bedroom closet 4. Failed 5' head test FBCR P2503.7 5. Missing screws per detail 10/SO.2, wind girt FBC(A) 107.4 6. Garage door not framed per plan (11/SO.2). Will need engineers letter FBC(A) 107.4 | |||
| ROOF VALLEY & METAL | 03/11/2025 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 03/04/2025 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/04/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 3/4/25 Will check at next inspection 1. SGD header missing (2) MSTA24 straps per plan FBC(A) 107.4 2. Header on opening accross stairs not per detail 7/SO.1 FBC(A) 107.4 3. On page S1.2, missing gable detail 10/SO.1 (highlighted on plan) FBC(A) 107.4 | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/24/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 02/13/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 2/13/25 1. Missing (1) #5 rebar on garage entry per detail 4B SO3 - FBC(A) 107.4 | |||
| MONOLITHIC SLAB | 02/13/2025 | APPROVED | MCONTRYMAN |
| Note: 2/13/2025 - PREVIOUS INSPECTION NOTES 2/13/25 1. Missing (1) #5 rebar on garage entry per detail 4B SO3 - FBC(A) 107.4 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/11/2025 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 06/24/2025 | 06/24/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| MECH | COMPLETE | 04/11/2025 | 04/11/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/03/2025 | 04/03/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/20/2025 | 03/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/13/2025 | 03/17/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide handrail detail per R311.7.8 through R311.7.8.3 and R311.7.8.5. | |||
| ENGIN1 | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/24/2025 | 01/29/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/24/2025 | 01/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/24/2025 | 01/29/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/24/2025 | 01/24/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/02/2025 | 01/07/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Upload revised state card when resubmitting (Second Request) | |||
| BADMIN | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/20/2024 | 12/20/2024 |
| Note: Released By: PAMELA MILLER - - | |||
| ELEC | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/20/2024 | 01/02/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/20/2024 | 12/23/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Upload revised state card when resubmitting | |||
| SW1 | HOLD | 12/20/2024 | 12/31/2024 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM 1. No on site benchmark shown on survey. 2. No elevations shown at the E/P nor BOC. 3. Adjacent lots are not described as improved nor vacant. 4. No existing elevations shown in nor around property lines. | |||
| ZON | COMPLETE | 12/20/2024 | 12/20/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 12/20/2024 | 12/20/2024 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/23/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 06/27/2025 |
| REINSPECTION FEE | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/03/2025 |
| CONNECTION FEES | ¤25.00 | 01/29/2025 |
| WATER-METER | ¤514.49 | 01/29/2025 |
| WATER-METER | ¤427.42 | 01/29/2025 |
| ADJUSTMENT 10% | (¤159.73) | 01/29/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/29/2025 |
| INSPECTION - RESIDENTIAL | ¤1,221.00 | 01/29/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤346.32 | 01/29/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 01/29/2025 |
| IMPACT FEE FIRE | ¤434.51 | 01/29/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/29/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/29/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 01/29/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/29/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 01/29/2025 |
| SURCHARGE FS 533.721 | ¤14.38 | 01/29/2025 |
| SURCHARGE - FS 468.631 | ¤21.56 | 01/29/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/29/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/29/2025 |
| SW ENG PRE APRON | ¤30.00 | 01/29/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/29/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/29/2025 |
| SEWER INSPECTION | ¤25.00 | 01/29/2025 |
| SITE PLAN 30 | ¤30.00 | 01/29/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,787.96 |