I want to search for...

Permit #2024120987

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00070-0200
CONDITIONED SPACE: 2494 sqft
GARAGE: 650 sqft
OPENED PORCH (WITH ROOF) : 392 sqft
PATIO/DECK (NO ROOF) : 64 sqft
Total Square Footage: 3600 sqft
Block: 00070
Subdivision: 2178 - SECTION 64-LAGUNA FOREST
Job Phone: 386-290-6543
Location Address: 36 LLOLEETA PATH
Type: DU - DUPLEX
Issue Date: 02/04/2025
NOC: RECORDED
Applicant name: JOHN DAVID MINABERRY
Owner: BELHUMEUR RICHARD D & SHANNON BELHUMEUR ALBIN TRUS

Address

PO BOX 504

FLAGLER BEACH, FL 32136

Lot: 0200
Contracted Stated Job Value: ¤400,000.00
Job Description: Duplex
Type: CN

Contractor

KEYSTONE HOMES
Status Location Address State License Number Phone Fax
ACTIVE

1339 W GRANADA BLVD

ORMOND, FL 32174

CRC1329222 (Exp: 08/31/2026) 386-672-6101 386-672-6102

Sub Contractors

DILLON CARRERAS
Status Location Address State License Number
ACTIVE

2909 MEADOWS LN

PALATKA, FL 32177

EC13010470 (Exp: 08/31/2026)
SHAWN MICHAEL HISS
Status Location Address State License Number Phone
ACTIVE

1315 LPGA BLVD

HOLLY HILL, FL 32117

CAC1813585 (Exp: 08/31/2026) (386)672-8688
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH MARTIN DELIA JR
Status Location Address State License Number Phone Fax
INACTIVE

200 PALMETTO PINES RD

DAYTONA BEACH, FL 32114

CCC1326358 (Exp: 08/31/2026) (386)673-6600 (386)673-6600

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/26/2025 FINAL APPROVED BTAYLOR
Note: 9/24/2025 - PREVIOUS INSPECTION NOTES 9/24/25 Both sides A&B 1. Electrical conduit to pep tank boxes are not glued, secured or sealed at points of contact and building 2. Per tanks need to be GFCi protected NEC 422.5 3. Seal up all ceiling and platform penetrations for AH (fire rating seal only) FBC-M1502.4.7 4. Seal up all wall anc ceiling penetrations in garages FBC 402.5.1.1 5. All outlets 6' from the edge of a sink are required to be GFCi protected NEC 210.8(7) 6. Microwaves needs to be GFCi or ARc Fault protected NEC 210 7. No permit pack on hand with Energy calcs to verify HVAC equipment FBC(A) 107.3.1 8. ODU has 30amp breaker installed and max of 20amp is allowed NEC 440.4AC 9. Porta-Jon needs to be removed Also: A Side: 1. Soffit vent missing screen B Side: 1. Loose outlet right side of SGD NEC 406.5 2. Master bath sink has hot/cold reversed FBCR P2722.2 3. Dryer duct needs to be capped or taped if not in use FBC-M1502.4.7
BLD - BUILDING FINAL 09/24/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 9/24/25 Both sides A&B 1. Electrical conduit to pep tank boxes are not glued, secured or sealed at points of contact and building 2. Per tanks need to be GFCi protected NEC 422.5 3. Seal up all ceiling and platform penetrations for AH (fire rating seal only) FBC-M1502.4.7 4. Seal up all wall anc ceiling penetrations in garages FBC 402.5.1.1 5. All outlets 6' from the edge of a sink are required to be GFCi protected NEC 210.8(7) 6. Microwaves needs to be GFCi or ARc Fault protected NEC 210 7. No permit pack on hand with Energy calcs to verify HVAC equipment FBC(A) 107.3.1 8. ODU has 30amp breaker installed and max of 20amp is allowed NEC 440.4AC 9. Porta-Jon needs to be removed Also: A Side: 1. Soffit vent missing screen B Side: 1. Loose outlet right side of SGD NEC 406.5 2. Master bath sink has hot/cold reversed FBCR P2722.2 3. Dryer duct needs to be capped or taped if not in use FBC-M1502.4.7
ROW - FINAL INSPECTION 09/22/2025 APPROVED FSLADISH
Note: 9/22/25 AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. ***INSPECTORS NOTE CULVERT PIPES NEED TO BE CLEANED OUT AND FREE OF DIRT/DEBRIS BEFORE ROW FINAL PASSAGE. ***
U -UTILITY RESIDENTIAL FINAL 09/22/2025 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No CC, No IRR
ROW FIELD SURVEY /GRADING CERTIFICATION 09/15/2025 APPROVED FSLADISH
Note: 9/15/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 09/15/2025 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR
ROW - FINAL APRON (AFTER POUR) 09/15/2025 APPROVED FSLADISH
Note: 9/15/25 PIPE ELEVATIONS GOOD, CUTS ARE MADE, CULVERT PIPE NOT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/03/2025 APPROVED TPOLACEK
ROW- PRE-APRON (PRE-POUR) 08/13/2025 APPROVED FSLADISH
Note: 8/13/25 SPOKE WITH CM AND LET HIM KNOW THAT ALL WATER NEEDS TO BE PUMPED OUT OF MITERED ENDS AND THAT THEY ARE MAINTAINED TO COPC 6"X6" MITERED END. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
GRAVITY SEWER TEST 07/31/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 Requesting AM if possible. WATER SERVICE NOT RAN YET
SEWER TIE IN 07/31/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 Requesting AM if possible. WATER SERVICE NOT RAN YET
WINDOW NAILING 07/30/2025 APPROVED CVANSTRAHLEN
Note: this is for interior garage door needing inspected
PEP TANK INSTALLATION REQUEST 07/16/2025 APPROVED CBOWERMASTER
ELECTRIC - EARLY POWER 07/07/2025 APPROVED - AS NOTED BTAYLOR
Note: 7-7-25 1. Emailed FPL at 12:08.
FIREWALL FINAL 05/19/2025 APPROVED CVANSTRAHLEN
INSULATION 05/13/2025 APPROVED - AS NOTED BTAYLOR
Note: 5-13-25 1. Garage man door not installed. Need to check once it is installed. 5/9/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5-6-25 1. Garage man doors not installed. 2. Master bathroom water lines need cover plates. 3. refridgerator water lines can not be back to back in center fire wall. 4. Middle bedroom smoke alarm to close to wall. 5. Smoke alarm in hallway to close to bathroom. 6. Outlet under sink needs to be moved.
LATH/BRICK/ WATER BARRIER 05/12/2025 APPROVED BTAYLOR
Note: 5/8/2025 3:55:21 PM- PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5-6-25 1. Garage man doors not installed. 2. Master bathroom water lines need cover plates. 3. refridgerator water lines can not be back to back in center fire wall. 4. Middle bedroom smoke alarm to close to wall. 5. Smoke alarm in hallway to close to bathroom. 6. Outlet under sink needs to be moved.
LATH/BRICK/ WATER BARRIER 05/09/2025 CANCELLED BY APPLICANT NDIMATTINA
Note: Inspector Notes from Inspection 2420 5-6-25 1. Garage man doors not installed. 2. Master bathroom water lines need cover plates. 3. refridgerator water lines can not be back to back in center fire wall. 4. Middle bedroom smoke alarm to close to wall. 5. Smoke alarm in hallway to close to bathroom. 6. Outlet under sink needs to be moved.
INSULATION 05/09/2025 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2420 5-6-25 1. Garage man doors not installed. 2. Master bathroom water lines need cover plates. 3. refridgerator water lines can not be back to back in center fire wall. 4. Middle bedroom smoke alarm to close to wall. 5. Smoke alarm in hallway to close to bathroom. 6. Outlet under sink needs to be moved.
ALL ROUGH 05/06/2025 APPROVED - AS NOTED BTAYLOR
Note: 5-6-25 1. Garage man doors not installed. 2. Master bathroom water lines need cover plates. 3. refridgerator water lines can not be back to back in center fire wall. 4. Middle bedroom smoke alarm to close to wall. 5. Smoke alarm in hallway to close to bathroom. 6. Outlet under sink needs to be moved.
FIREWALL DRYWALL NAILING 04/11/2025 APPROVED BTAYLOR
Note: 4/10/2025 - PREVIOUS INSPECTION NOTES 4/10/25 1. Nailing/screws, must be a max 6" on the edges and 6" in the field FBC R702.3.5
FIREWALL DRYWALL NAILING 04/10/2025 Disapproved - NO FEE MCONTRYMAN
Note: 4/10/25 1. Nailing/screws, must be a max 6" on the edges and 6" in the field FBC R702.3.5
ROOF VALLEY & METAL 04/03/2025 APPROVED BTAYLOR
WALL SHEATHING 04/02/2025 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/02/2025 APPROVED MCONTRYMAN
FIREWALL FRAMING 04/02/2025 APPROVED MCONTRYMAN
TIE BEAM / LINTEL 03/19/2025 APPROVED MCONTRYMAN
FOUND SURVEY APPROVED (OFFICE) 03/04/2025 APPROVED RRICKS
MONOLITHIC SLAB 03/04/2025 APPROVED BTAYLOR
WATER METER INSTALLATION REQUEST 03/03/2025 APPROVED CBOWERMASTER
PLUMBING 1ST ROUGH UNDERGROUND 02/27/2025 APPROVED - AS NOTED MGIBSON
Note: Requesting AM if possible. WATER SERVICE NOT RAN YET
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/26/2025 APPROVED CPISCITELLI

Review History

Department Status Date In Date Out
BADMIN INFORMATION 09/16/2025 09/16/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Termite certificate addess please correct street name.
ZON COMPLETE 07/14/2025 07/14/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 07/14/2025 07/14/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename your file name correctly.
ENGIN1 COMPLETE 07/14/2025 07/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 07/14/2025 07/15/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/07/2025 07/08/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 07/07/2025 07/08/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 07/07/2025 07/07/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Driveways cannot exceed 20ft for a one car garage Walkways cannot exceed 6ft in width
ENGIN1 COMPLETE 03/03/2025 03/04/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/03/2025 03/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN INFORMATION 02/28/2025 02/28/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM we only take termite certificates not the intended future treatment
BLD COMPLETE 02/25/2025 02/26/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/28/2025 01/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 01/23/2025 01/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 01/23/2025 01/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 01/23/2025 01/28/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 01/23/2025 01/28/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Need Florida product approval number for all structural components and soffits. 2. Truss packet or truss layout needs shop drawing approval stamp by engineer of record (Second Request)
SWALE COMPLETE 12/27/2024 01/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 12/26/2024 01/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 12/26/2024 01/03/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need Florida product approval number for all structural components and soffits. 2. Truss packet or truss layout needs shop drawing approval stamp by engineer of record 3. For CMU wall provide source for fire restive rating, ASTM E119, UL 263 or section 703.3 FRC 2023 R302.3 4. Provide fire restive for dwelling unit wall in attic, ASTM E119, UL 263 or section 703.3 FRC 2023 R302.3 5. Add note that any penetrating items through the attic separation wall to comply with R302.4.1-R302.4.2 FRC 2023.
CUSVC COMPLETE 12/26/2024 12/27/2024
Note: Released By: PAMELA MILLER - -
ELEC HOLD 12/26/2024 01/02/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit Electrical load calculations 2. Range needs to be GFCI protected. NEC 2020 210.8 3. DW outlet can not be located behind the DW. NEC 2020 422.16
ENGIN1 COMPLETE 12/26/2024 12/27/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 12/26/2024 12/26/2024
LOCATE COMPLETE 12/26/2024 01/02/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 12/26/2024 12/26/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition 2. State card is the page with the preparers signature on it. Upload this page only and please make sure it is signed by the builder. AHJ 3. Provide duct layout signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
SW1 COMPLETE 12/26/2024 01/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 12/26/2024 12/26/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation plan: Right side labeled front should be right side Please contact Estelle Lens 386-986-2655 as this property is a drop lot and will require a development order for drop lots.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/30/2025
CONNECTION FEES ¤2,374.52 02/04/2025
FC IMPACT FEE EMS ¤124.00 02/04/2025
IMPACT FEE FIRE ¤869.02 02/04/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/04/2025
FC IMPACT FEE LIBRARY ¤536.00 02/04/2025
IMPACT FEE PARKS ¤3,656.02 02/04/2025
IMPACT FEE SCHOOL ¤10,900.00 02/04/2025
IMPACT FEE TRANSPORTATION ¤2,890.00 02/04/2025
WATER -IRRIGATION INSPECTION ¤50.00 02/04/2025
SURCHARGE FS 533.721 ¤15.84 02/04/2025
SURCHARGE - FS 468.631 ¤23.76 02/04/2025
SW ENG - FOUNDATION SURVEY ¤20.00 02/04/2025
SW ENG INSPECTION 80 ¤80.00 02/04/2025
SW ENG PRE APRON ¤30.00 02/04/2025
SW ENG - REVIEW 20 ¤20.00 02/04/2025
SW ENG RES REVIEW 200 ¤200.00 02/04/2025
SEWER INSPECTION ¤25.00 02/04/2025
SEWER CAPITAL FACILITY ¤12,241.04 02/04/2025
WATER CAPITAL FACILITY FEE ¤8,702.28 02/04/2025
SITE PLAN 30 ¤30.00 02/04/2025
WATER- TURN ON ¤50.00 02/04/2025
ADJUSTMENT 10% (¤175.97) 02/04/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/04/2025
INSPECTION - RESIDENTIAL ¤1,347.50 02/04/2025
PLAN REVIEW - RESIDENTIAL ¤382.20 02/04/2025
Fees Total Due: ¤0.00 Total Paid: ¤44,897.21