I want to search for...
Permit #2024121089
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7012-00140-0400 |
| Total Square Footage: 3305 sqft |
| Block: 00140 |
| Subdivision: 7012 - |
| Job Phone: 321-439-6423 |
| Location Address: 80 BARRINGTON DR |
| Type: ME - MECHANICAL |
| Issue Date: 12/30/2024 |
| NOC: Unknown |
| Applicant name: JACOB ALI ANZANI |
| Owner: LAMBERSON JAMES REID & JUDITH ELAINE LAMBERSON TRU |
|
Address 80 BARRINGTON DRIVE PALM COAST, FL 32137 |
| Lot: 0400 |
| Contracted Stated Job Value: ¤9,800.00 |
| Job Description: HVAC CO like for like |
| Type: CN |
Contractor
BLUE LINE ROOFING
| Status | Location Address | State License Number | Phone |
| INACTIVE |
881 BARTON BOULEVARD ROCKLEDGE, FL 32955 |
CAC1821980 (Exp: 08/31/2026) | 321-439-6423 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 02/18/2025 | FINAL APPROVED | JSTEWART |
| Note: 2/6/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/6/2025 2:35:38 PM *** Condensor and Air Handler are not Listed of being compatible,(Lookup of model Numbers), will need to swap air handler to match Condensor. does not meet 14.30 seer requiremnet. (Mixed equipment). FBEC C501.6 1/22/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/22/2025 12:14:06 PM *** 1. Please seal supply plenum at AHU, Tape used is not holding loss of Air/heat is high. FBCM.603.1 2. Please revise AHRI cert to match equipment installed. FBC [A] 107.4 3. Please change breaker for ODU requires 40amp max, 50amp is installed. MFBC 1303 4. Please secure Liquid tight (power) at disconnect (within 12" of entrance to box. NEC 334.30 5. Please verify Mixed equipment is compatible in Voltage, terms of capacity, warranty, etc. (ties in with the correct AHRI certification) | |||
| HVAC FINAL | 02/06/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 2/6/2025 2:35:38 PM *** Condensor and Air Handler are not Listed of being compatible,(Lookup of model Numbers), will need to swap air handler to match Condensor. does not meet 14.30 seer requiremnet. (Mixed equipment). FBEC C501.6 1/22/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/22/2025 12:14:06 PM *** 1. Please seal supply plenum at AHU, Tape used is not holding loss of Air/heat is high. FBCM.603.1 2. Please revise AHRI cert to match equipment installed. FBC [A] 107.4 3. Please change breaker for ODU requires 40amp max, 50amp is installed. MFBC 1303 4. Please secure Liquid tight (power) at disconnect (within 12" of entrance to box. NEC 334.30 5. Please verify Mixed equipment is compatible in Voltage, terms of capacity, warranty, etc. (ties in with the correct AHRI certification) | |||
| HVAC FINAL | 01/22/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 1/22/2025 12:14:06 PM *** 1. Please seal supply plenum at AHU, Tape used is not holding loss of Air/heat is high. FBCM.603.1 2. Please revise AHRI cert to match equipment installed. FBC [A] 107.4 3. Please change breaker for ODU requires 40amp max, 50amp is installed. MFBC 1303 4. Please secure Liquid tight (power) at disconnect (within 12" of entrance to box. NEC 334.30 5. Please verify Mixed equipment is compatible in Voltage, terms of capacity, warranty, etc. (ties in with the correct AHRI certification) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/14/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/24/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/30/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/30/2024 |
| ADJUSTMENT 10% | (¤9.00) | 12/30/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/30/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 12/30/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤165.00 |