Permit #2025010182

Permit Details

Status: FINAL

Parcel Id: 08-12-31-5830-00000-0000
Block: 00000
Subdivision: 5830 -
Job Phone: 386-503-1070
Location Address: 402 TUSCAN RESERVE DR
Type: PM - POOL MISCELLANEOUS
Issue Date: 01/17/2025
NOC: RECORDED
Applicant name: THOMAS A RUBINO
Owner: BC TUSCAN RESERVE LLC & WS TUSCAN RESERVE LLC & JS

Address

420 TUSCAN RESERVE DRIVE

PALM COAST, FL 32164

Address

ATTN: KIM ROSSINGTON TUSCAN RESERVE APARTMENTS

PALM COAST, FL 32164

Lot: 0000
Contracted Stated Job Value: ¤7,500.00
Job Description: Replaster and retile pool
Type: CN
Original Permit #: 2024030709

Contractor

SWIM KING INC.
Status Location Address State License Number Phone Fax
ACTIVE

8 LAMBERT COVE

FLAGLER BEACH, FL 32136

CPC1456615 (Exp: 08/31/2026) (386)439-0004 (386)439-8816

Inspection History

Type Request Date Result Inspector
POOL FINAL 01/28/2026 FINAL APPROVED KSANDOE
Note: 1/21/2026 - PREVIOUS INSPECTION NOTES Previously listed items must be addressed 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 - DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 9/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/23/2024 4:18:02 PM *** Please be advised there may be additional deficiencies once the documents needed for the inspection are supplied... 1. Need approved documents on site for inspection FBC 107.4 (also need to coordinate with the amenity center contractor to have the amenity center documents on site for the inspection also. We need to be able to check the occupancy load and the ADA. 2. Need to get the Spa working prior to final. 3. Need to make repairs and resolve the hole and work area around the equipment. 4. Need a minimum of 12 inches width of sidewalk beyond the hinge side and 18 beyond the latch side of the gate for ADA Access. per FBC-A TABLE 404.2.4.15. Need a minimum of 10 inches of smooth solid surface on the bottom of the gate at the push side per FBC-A 404.2.10 6. Need pool lift per FBC-A section 1009 or reason for exemption.
POOL FINAL 01/21/2026 Disapproved -FEE REQUIRED KSANDOE
Note: Previously listed items must be addressed 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 - DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 9/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/23/2024 4:18:02 PM *** Please be advised there may be additional deficiencies once the documents needed for the inspection are supplied... 1. Need approved documents on site for inspection FBC 107.4 (also need to coordinate with the amenity center contractor to have the amenity center documents on site for the inspection also. We need to be able to check the occupancy load and the ADA. 2. Need to get the Spa working prior to final. 3. Need to make repairs and resolve the hole and work area around the equipment. 4. Need a minimum of 12 inches width of sidewalk beyond the hinge side and 18 beyond the latch side of the gate for ADA Access. per FBC-A TABLE 404.2.4.15. Need a minimum of 10 inches of smooth solid surface on the bottom of the gate at the push side per FBC-A 404.2.10 6. Need pool lift per FBC-A section 1009 or reason for exemption.
POOL FINAL 11/05/2024 Disapproved -FEE REQUIRED FWILLIS
Note: 11/5/24 - DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 9/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/23/2024 4:18:02 PM *** Please be advised there may be additional deficiencies once the documents needed for the inspection are supplied... 1. Need approved documents on site for inspection FBC 107.4 (also need to coordinate with the amenity center contractor to have the amenity center documents on site for the inspection also. We need to be able to check the occupancy load and the ADA. 2. Need to get the Spa working prior to final. 3. Need to make repairs and resolve the hole and work area around the equipment. 4. Need a minimum of 12 inches width of sidewalk beyond the hinge side and 18 beyond the latch side of the gate for ADA Access. per FBC-A TABLE 404.2.4.15. Need a minimum of 10 inches of smooth solid surface on the bottom of the gate at the push side per FBC-A 404.2.10 6. Need pool lift per FBC-A section 1009 or reason for exemption.
POOL FINAL 09/23/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 9/23/2024 4:18:02 PM *** Please be advised there may be additional deficiencies once the documents needed for the inspection are supplied... 1. Need approved documents on site for inspection FBC 107.4 (also need to coordinate with the amenity center contractor to have the amenity center documents on site for the inspection also. We need to be able to check the occupancy load and the ADA. 2. Need to get the Spa working prior to final. 3. Need to make repairs and resolve the hole and work area around the equipment. 4. Need a minimum of 12 inches width of sidewalk beyond the hinge side and 18 beyond the latch side of the gate for ADA Access. per FBC-A TABLE 404.2.4.15. Need a minimum of 10 inches of smooth solid surface on the bottom of the gate at the push side per FBC-A 404.2.10 6. Need pool lift per FBC-A section 1009 or reason for exemption.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 01/20/2026
ADMINISTRATIVE - EXTENSION ¤40.00 12/15/2025
EXTENSION ¤40.00 12/15/2025
ADJUSTMENT 10% (¤9.00) 01/17/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/17/2025
INSPECTION - RESIDENTIAL ¤60.00 01/17/2025
REINSPECTION RESIDENTIAL ¤40.00 01/17/2025
SURCHARGE FS 533.721 ¤2.00 01/17/2025
SURCHARGE - FS 468.631 ¤2.00 01/17/2025
Fees Total Due: ¤0.00 Total Paid: ¤245.00