Status: FINAL
| Parcel Id: 07-11-31-7023-00240-0120 |
| Block: 00240 |
| Subdivision: 7023 - |
| Job Phone: 386-216-9945 |
| Location Address: 16 WHITTIER LN |
| Type: PO - POOL |
| Issue Date: 01/29/2025 |
| NOC: RECORDED |
| Applicant name: CASEY C WATSON |
| Owner: KECHKIN ILYA VALERYEVICH & YANA SIVETS H&W |
|
Address 16 WHITTIER LANE PALM COAST, FL 32164 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤91,103.00 |
| Job Description: POOL WITH SCREEN ENCLOSURE |
| Type: CN |
Contractor
EXQUISITE POOL & SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3895 BRITTING DR DELAND, FL 32724 |
CPC1457932 (Exp: 08/31/2026) | 386-216-9945 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
JOHN LEROY HODGINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2020 COUNTRY FARMS RD PORT ORANGE, FL 32128 |
CGC1507254 (Exp: 08/31/2026) | 386-547-2998 | 386-788-4028 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 07/01/2025 | FINAL APPROVED | MKRASKI |
| Note: | |||
| POOL FINAL | 06/26/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Bond wire must be protected with in 3' of grade (near heater) NEC 250.64(A)(2) 2. 2x6s on cage (back corners) missing L brackets Per plans FBC (A)107.4 3. No screen engineering drawling onsite FBC 107.3.1 4. Pool chlorinator must be GFCI protected FBC 4501.16/NEC 680.21(C)/NEC 680.22 | |||
| U -UTILITY RESIDENTIAL FINAL | 06/25/2025 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/24/2025 | APPROVED | TPOLACEK |
| Note: CORRECTIONS MADE. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 6/18/2025 - PREVIOUS INSPECTION NOTES 06/18/25 TPOLACEK*** FINAL SURVEY AND FIELD DO NOT MATCH. PLEASE SEE ATTACHED PHOTO SHOWING A HIGH AREA ( BLACK) AND A LOW AREA (IN RED) THAT WILL NOT ALLOW DRAINAGE TO FUNCTION CORRECLTY. PLEASE MAKE CORRECTIONS AND REQUEST A NEW FIELD SURVEY. | |||
| ROW - FINAL INSPECTION | 06/24/2025 | APPROVED | TPOLACEK |
| Note: . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/18/2025 | APPROVED | TPOLACEK |
| Note: 6/9/2025 - PREVIOUS INSPECTION NOTES 06/09/25 TPOLACEK** REAR YARD DRAINAGE NEEDS TO HAVE MORE ELEVATION SHOTS TO PROPERLY DETERMINE IF DRAINAGE WILL WORK. DRAINAGE IS REQUIRED TO MOVE FROM THE REAR TO THE FRONT SWALE. PLEASE READ CODES BELOW TO ENSURE YOU MEET THE MINIMUM REQUIREMENTS BEFORE SUBMITTING NEW FINAL SURVEY. PLEASE SEE ATTACHED PHOTO SHOWING AREAS OF CONCERN. Finished Floor Elevations (FFE): Section 300.01 B(4) V-15 4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(5) V-17 5) The minimum fall from the rear property line to the front is 0.50 of a foot. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of the swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/18/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 06/18/25 TPOLACEK*** FINAL SURVEY AND FIELD DO NOT MATCH. PLEASE SEE ATTACHED PHOTO SHOWING A HIGH AREA ( BLACK) AND A LOW AREA (IN RED) THAT WILL NOT ALLOW DRAINAGE TO FUNCTION CORRECLTY. PLEASE MAKE CORRECTIONS AND REQUEST A NEW FIELD SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/09/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 06/09/25 TPOLACEK** REAR YARD DRAINAGE NEEDS TO HAVE MORE ELEVATION SHOTS TO PROPERLY DETERMINE IF DRAINAGE WILL WORK. DRAINAGE IS REQUIRED TO MOVE FROM THE REAR TO THE FRONT SWALE. PLEASE READ CODES BELOW TO ENSURE YOU MEET THE MINIMUM REQUIREMENTS BEFORE SUBMITTING NEW FINAL SURVEY. PLEASE SEE ATTACHED PHOTO SHOWING AREAS OF CONCERN. Finished Floor Elevations (FFE): Section 300.01 B(4) V-15 4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(5) V-17 5) The minimum fall from the rear property line to the front is 0.50 of a foot. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of the swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. | |||
| ELECTRIC AND ALARM | 05/08/2025 | APPROVED | MCONTRYMAN |
| POOL DECK | 04/10/2025 | APPROVED | MKRASKI |
| Note: | |||
| POOL DECK | 04/09/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Missing 4th point of bonding of shell steel to perimeter surface bomnd wire NEC 680.26.4 2. All footing steel must have a min of 3'' clearence from soil FBC R404.1.3.3.7.4 | |||
| STEEL AND GROUND | 02/12/2025 | APPROVED | MKRASKI |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 01/23/2025 | 01/23/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/23/2025 | 01/29/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/22/2025 | 01/22/2025 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM plans missing digital seal | |||
| BFLOOD | COMPLETE | 01/15/2025 | 01/21/2025 |
| Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/15/2025 | 01/21/2025 |
| Note: Held By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM 1. Screen Enclosure plans missing. Pool plans attached instead. | |||
| ELEC | COMPLETE | 01/15/2025 | 01/22/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/15/2025 | 01/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/15/2025 | 01/21/2025 |
| Note: Released By: TOM POLACEK - (386)346-8986 - 01/21/25 TPOLACEK*** THE REAR YARD IS REQUIRED TO DRAIN TO THE FRONT YARD SWALE. | |||
| ZON | HOLD | 01/15/2025 | 01/15/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Screen enclosure plans missing What is labeled as screen plans are pool plans |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤26.18) | 01/29/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/29/2025 |
| INSPECTION- POOL | ¤160.00 | 01/29/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤71.76 | 01/29/2025 |
| SURCHARGE FS 533.721 | ¤2.36 | 01/29/2025 |
| SURCHARGE - FS 468.631 | ¤3.53 | 01/29/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 01/29/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/29/2025 |
| SITE PLAN 30 | ¤30.00 | 01/29/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤331.47 |