I want to search for...
Permit #2025011138
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7024-00030-0210 |
| Block: 00030 |
| Subdivision: 7024 - |
| Job Phone: 386-503-6922 |
| Location Address: 9 PRINCESS KATHLEEN LN |
| Type: PO - POOL |
| Issue Date: 02/18/2025 |
| NOC: RECORDED |
| Applicant name: JOSE E ORTIZ JR |
| Owner: LOPEZ GALO D & MARIANNE H&W |
|
Address 9 PRINCESS KATHLEEN LN PALM COAST, FL 32164 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤65,000.00 |
| Job Description: Pool build with screen |
| Type: CN |
Contractor
JOSE E ORTIZ JR LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD A3 PALM COAST, FL 32164 |
CPC1460694 (Exp: 08/31/2026) | 386-313-6055 |
Sub Contractors
RICHARD SWAN TOWNSEND II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3111 OPPORTUNITY CT SUITE D PORT ORANGE, FL 32129 |
CGC1515792 (Exp: 08/31/2026) | 386-756-8770 |
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 12/05/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/5/2025 11:01:14 AM *** 12/4/2025 - PREVIOUS INSPECTION NOTES 12/4/25: Noone home at the time of inspection. 1). Interior remote alarm is not visible from exterior and no magnet was available for pool side alarm. Could not test as required. FBC-[A] 110.1 / FBC- R4501.17.1.9 | |||
| POOL FINAL | 12/04/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/4/2025 1:50:45 PM *** 12/4/25: Noone home at the time of inspection. 1). Interior remote alarm is not visible from exterior and no magnet was available for pool side alarm. Could not test as required. FBC-[A] 110.1 / FBC- R4501.17.1.9 | |||
| U -UTILITY RESIDENTIAL FINAL | 12/03/2025 | FINAL APPROVED | BHAINES |
| ROW - DRAINAGE | 12/02/2025 | APPROVED | TPOLACEK |
| Note: 3/3/2025 - PREVIOUS INSPECTION NOTES 3/3/25 YOU ARE NOT ALLOWED TO DUMP YOUR POOL DISCHARGE HOSE INTO THE COPC SWALE SYSTEM WITHOUT MOVING IT TO 10FT BEHIND THE ROW AND HAVE A FILTER SOCK OR SOME OTHER FORM OF ACCEPTABLE FILTRATION BEFORE IT ENTERS INTO THE COPC STORMWATER CHANNELING SYSTEM. THIS IS CONSIDERED AN ILLICIT DISCHARGE AND NEEDS TO BE REMEDIED IMMEDIATELY. I WILL BE BACK FOR COMPLIANCE REINSPECTION 3/4/25. PLEASE MAKE REQUIRED CORRECTION. PHOTO FOR REFERENCE. | |||
| ROW - FINAL INSPECTION | 12/02/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/02/2025 | APPROVED | TPOLACEK |
| Note: 7/21/2025 - PREVIOUS INSPECTION NOTES 07/21/25 TPOLACEK*** FINAL SURVEY DOES NOT MATCH THE APPROVED PROPOSED DRAINAGE PATTERN FROM THE SITE PLAN. PLEASE SEE ATTACHED PHOTO ALL DRAINAGE MUST FLOW TO FRONT SWALE AND NOT IMPACT ADJOINING PROPERTIES. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/02/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/21/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 07/21/25 TPOLACEK*** FINAL SURVEY DOES NOT MATCH THE APPROVED PROPOSED DRAINAGE PATTERN FROM THE SITE PLAN. PLEASE SEE ATTACHED PHOTO ALL DRAINAGE MUST FLOW TO FRONT SWALE AND NOT IMPACT ADJOINING PROPERTIES. 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) | |||
| ELECTRIC AND ALARM | 05/15/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/15/2025 12:58:32 PM *** Approved | |||
| POOL DECK | 04/17/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/17/2025 12:49:21 PM *** 4/14/2025 - PREVIOUS INSPECTION NOTES 4/14/25: Cancelled by Applicant via phone call at @ 13:08. NOT READY! 4/11/2025 - PREVIOUS INSPECTION NOTES 4/11/25: No change from previous inspection on 4/8/25. No revision submitted. 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/4/2025 - PREVIOUS INSPECTION NOTES 4/4/25: NOT READY! 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 2). Footers are missing rebar (FBC [A]107.4), existing installed rebar does not have 3" clearance as required (FBC R404.1.3.3.7.4 ), footers are not complete and have dirt cave in.(FBC [A]107.4) 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 | |||
| POOL DECK | 04/14/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/14/2025 1:08:24 PM *** 4/14/25: Cancelled by Applicant via phone call at @ 13:08. NOT READY! 4/11/2025 - PREVIOUS INSPECTION NOTES 4/11/25: No change from previous inspection on 4/8/25. No revision submitted. 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/4/2025 - PREVIOUS INSPECTION NOTES 4/4/25: NOT READY! 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 2). Footers are missing rebar (FBC [A]107.4), existing installed rebar does not have 3" clearance as required (FBC R404.1.3.3.7.4 ), footers are not complete and have dirt cave in.(FBC [A]107.4) 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 | |||
| POOL DECK | 04/11/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/11/2025 1:26:16 PM *** 4/11/25: No change from previous inspection on 4/8/25. No revision submitted. 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Revision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/4/2025 - PREVIOUS INSPECTION NOTES 4/4/25: NOT READY! 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 2). Footers are missing rebar (FBC [A]107.4), existing installed rebar does not have 3" clearance as required (FBC R404.1.3.3.7.4 ), footers are not complete and have dirt cave in.(FBC [A]107.4) 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 | |||
| POOL DECK | 04/08/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/8/2025 10:45:13 AM *** 4/8/25: Rvision or correction required. Previously listed item 1: 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 At this inspection deck does not meet minimum depth of 4" at existing slab as required on plan. - Highlighted Previously listed item 3 remains unresolved.: 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 - Highlighted. 4/4/2025 - PREVIOUS INSPECTION NOTES 4/4/25: NOT READY! 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 2). Footers are missing rebar (FBC [A]107.4), existing installed rebar does not have 3" clearance as required (FBC R404.1.3.3.7.4 ), footers are not complete and have dirt cave in.(FBC [A]107.4) 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 | |||
| POOL DECK | 04/04/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/4/2025 1:49:02 PM *** 4/4/25: NOT READY! 1). slab area needs to be clear of any material and/or debris. FBC R318.6.2 / FBC [A]107.4 2). Footers are missing rebar (FBC [A]107.4), existing installed rebar does not have 3" clearance as required (FBC R404.1.3.3.7.4 ), footers are not complete and have dirt cave in.(FBC [A]107.4) 3). Concrete specification on page 1 - #4 of the screen enclosure plans call for rebar pins to be installed at every 48" minimum. FBC [A]107.4 | |||
| STEEL AND GROUND | 03/03/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/3/2025 8:34:19 AM *** | |||
| ROW - DRAINAGE | 03/03/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 3/3/25 YOU ARE NOT ALLOWED TO DUMP YOUR POOL DISCHARGE HOSE INTO THE COPC SWALE SYSTEM WITHOUT MOVING IT TO 10FT BEHIND THE ROW AND HAVE A FILTER SOCK OR SOME OTHER FORM OF ACCEPTABLE FILTRATION BEFORE IT ENTERS INTO THE COPC STORMWATER CHANNELING SYSTEM. THIS IS CONSIDERED AN ILLICIT DISCHARGE AND NEEDS TO BE REMEDIED IMMEDIATELY. I WILL BE BACK FOR COMPLIANCE REINSPECTION 3/4/25. PLEASE MAKE REQUIRED CORRECTION. PHOTO FOR REFERENCE. |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | HOLD | 09/03/2025 | 09/03/2025 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME FILE NAME TO APPLICATION.PDF 2. PERMIT APPLICATION MISSING ESTIMATED VALUE | |||
| BADMIN | COMPLETE | 09/03/2025 | 09/03/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/11/2025 | 02/11/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/11/2025 | 02/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/11/2025 | 02/18/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/06/2025 | 02/06/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM No new screen plans uploaded. Screen plans submitted are not for this address | |||
| BLD | HOLD | 02/06/2025 | 02/11/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1.upload approved master file plans | |||
| ELEC | HOLD | 02/06/2025 | 02/11/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1.upload approved master file plans | |||
| BFLOOD | CANCEL | 01/28/2025 | 02/04/2025 |
| BLD | HOLD | 01/28/2025 | 01/31/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Need 3rd page of the TDH. 2. Please provide pool enclosure engineering. The drawings attached are for the elite panels. Also, clarify and show as part of the pool enclosure where the panels will be installed. | |||
| ELEC | HOLD | 01/28/2025 | 02/04/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Master pool file is expired. | |||
| MECH | COMPLETE | 01/28/2025 | 01/31/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/28/2025 | 02/04/2025 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/28/2025 | 01/28/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Screen plans submitted are not for this address |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 12/03/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/11/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/02/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/02/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 02/18/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/18/2025 |
| SITE PLAN 30 | ¤30.00 | 02/18/2025 |
| SURCHARGE FS 533.721 | ¤2.30 | 02/18/2025 |
| SURCHARGE - FS 468.631 | ¤3.44 | 02/18/2025 |
| INSPECTION- POOL | ¤160.00 | 02/18/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 02/18/2025 |
| ADJUSTMENT 10% | (¤25.50) | 02/18/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/18/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤545.24 |