Permit #2025011144
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00340-0040 |
| Block: 00340 |
| Subdivision: 7028 - |
| Job Phone: 386-503-6922 |
| Location Address: 10 POST LN |
| Type: RF - REROOF |
| Issue Date: 01/30/2025 |
| NOC: RECORDED |
| Applicant name: JOSE E ORTIZ JR |
| Owner: MOROSHEK GREGORY & YELENA MOROSHEK H&W |
|
Address 5050 XIMINES LANE N PLYMOUTH, MN 55442 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤18,000.00 |
| Job Description: re-roof |
| Type: CN |
Contractor
JOSE E ORTIZ JR LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD, STE A3 BUNNELL, FL 32110 |
CCC1334839 (Exp: 08/31/2026) | 386-313-6055 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF IN PROGRESS- MIDROOF | 02/25/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 2/25/25 Approved based upon engineers letter 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25: Revised engineer's letter has been submitted to and approved by the City. 1). Fastener spacing exceeds the maximum spacing along the panel as required by the specifications in the Engineer's revised letter. (4-3/4"). 2/10/2025 8:58:26 AM- PREVIOUS INSPECTION NOTES 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF FINAL | 02/25/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2468 2/25/25 Approved based upon engineers letter 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25: Revised engineer's letter has been submitted to and approved by the City. 1). Fastener spacing exceeds the maximum spacing along the panel as required by the specifications in the Engineer's revised letter. (4-3/4"). 2/10/2025 8:58:26 AM- PREVIOUS INSPECTION NOTES 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF AFFIDAVIT | 02/18/2025 | APPROVED | NDIMATTINA |
| ROOF SHEATHING | 02/12/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/12/2025 10:33:21 AM *** 2/12/25: Approved as noted based on submitted engineer's letter reviewed by the City. 2/7/2025 9:36:19 AM- PREVIOUS INSPECTION NOTES 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF IN PROGRESS- MIDROOF | 02/12/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/12/2025 10:37:05 AM *** 2/12/25: Revised engineer's letter has been submitted to and approved by the City. 1). Fastener spacing exceeds the maximum spacing along the panel as required by the specifications in the Engineer's revised letter. (4-3/4"). 2/10/2025 8:58:26 AM- PREVIOUS INSPECTION NOTES 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF SHEATHING | 02/10/2025 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF IN PROGRESS- MIDROOF | 02/10/2025 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: 2/4/2025 - PREVIOUS INSPECTION NOTES 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF IN PROGRESS- MIDROOF | 02/04/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/4/2025 10:57:43 AM *** 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). | |||
| ROOF SHEATHING | 02/04/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/4/2025 10:58:09 AM *** 2/4/25: 1). Original roof deck is 15/32" OSB, Manufacturer's approved installation instructions for the installed roof panels clearly requires B-C 4ply plywood as shown in the instructions below. Correction or revision with manufacturer's engineer approval is required. ** Roof Deck: Armour 5-V Crimp 0.032” aluminum roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/11/2025 | 02/11/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/10/2025 | 02/11/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide uplift calculations or Engineer to include certification statement in accordance with Florida Administrative Code 61G15-18.011 (4) certiying this roof deck can withstand the uplift pressures | |||
| BLD | HOLD | 02/07/2025 | 02/07/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW. PREVIOUS WAS COMPLETED IN ERROR This letter not accepted. You cannot override the Engineer of the product approval report. You can provide a report from a licensed Florida P.E. that is site specific, evaluates the existing roof deck and includes deck material and size. The report also needs to show that the roof deck can withstand the new uplifts occurred by the metal panel roofing. (Provide Calculations) | |||
| BLD | COMPLETE | 02/06/2025 | 02/07/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/30/2025 | 01/30/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/28/2025 | 01/28/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please indicate the specific metal shingle to be used by providing the digit after the point. 2. FL# 5259 R30 is out of cycle. We are in the 2023 review cycle. | |||
| BLD | HOLD | 01/28/2025 | 01/29/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please indicate the specific metal panel to be used by providing the digit after the point. Example 24397.1,2,3,4. They are different sheets and instalation requirements. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/19/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/30/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 01/30/2025 |
| ADJUSTMENT 10% | (¤9.00) | 01/30/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/30/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 01/30/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |