I want to search for...

Permit #2025011292

Permit Details

Status: COED

Parcel Id: 35-11-31-4075-00000-0840
CONDITIONED SPACE: 2968 sqft
GARAGE: 760 sqft
OPENED PORCH (WITH ROOF) : 584 sqft
Total Square Footage: 4312 sqft
Block: 00000
Subdivision: -
Job Phone: (386)566-3290
Location Address: 33 DEL PALMA DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/24/2025
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: WHELAN JAMES & HEIDI H&W

Address

2823 W PAINTED CANYON WAY

HIGHLANDS RANCH, CO 80129

Lot: 0840
Contracted Stated Job Value: ¤450,000.00
Job Description: single family residence.
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BERT S MCLAUGHLIN
Status Location Address State License Number Phone
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13006455 (Exp: 08/31/2026) 386-265-2687
JEFFREY R SHELTON
Status Location Address State License Number Phone
ACTIVE

6260 WESTVIEW DR, STE 200

ORLANDO, FL 32824

LQ3517 (Exp: 07/23/2027) 301-302-8053
RICHARD LEE VONBROCKEN
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952
PEDRO DANIEL CHINCHILLA
Status Location Address State License Number Phone
ACTIVE

324 COVENT GARDENS PL

DELTONA, FL 32725

CCC1333997 (Exp: 08/31/2026) 386-679-6228
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/20/2025 Approval - Private Provider PPROVIDER
Note: 11/13/2025 12:52:29 PM- PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 11/13/2025 Disapproved- Private Provider PPROVIDER
U -UTILITY RESIDENTIAL FINAL 11/13/2025 FINAL APPROVED BHAINES
Note: 11/7/2025 - PREVIOUS INSPECTION NOTES unable to locate sewer clean out/remove hose bib from water meter assembly-make sure residence has water service
ROW - STORMWATER FINAL 11/07/2025 APPROVED FSLADISH
Note: 11/7/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________--- 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25 SPOKE WITH CM AND LET HIM KNOW SINCE JULY 1ST WHAT OUR NEW REQUIREMENTS WITH REGARD TO EROSION CONTROL FOR ANY DISTURBED AREAS DURING CONSTRUCTION ARE. HE IS GOING TO LAY SOD ON THE BARE AREA IN REAR AND 10' ON THE VACANT LOT ON RIGHT SIDE TO CONTROL EROSION. CANCELLING AS A COURTESY DUE TO COMMUNICATION WITH INSPECTOR. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.***
U -UTILITY RESIDENTIAL FINAL 11/07/2025 Disapproved -FEE REQUIRED LFITZGERALD
Note: unable to locate sewer clean out/remove hose bib from water meter assembly-make sure residence has water service
U-CROSS CONNECTION 11/07/2025 APPROVED - AS NOTED LFITZGERALD
Note: irrigatiion meter=no cc
ROW - STORMWATER FINAL 10/30/2025 CANCELLED BY APPLICANT FSLADISH
Note: 10/30/25 SPOKE WITH CM AND LET HIM KNOW SINCE JULY 1ST WHAT OUR NEW REQUIREMENTS WITH REGARD TO EROSION CONTROL FOR ANY DISTURBED AREAS DURING CONSTRUCTION ARE. HE IS GOING TO LAY SOD ON THE BARE AREA IN REAR AND 10' ON THE VACANT LOT ON RIGHT SIDE TO CONTROL EROSION. CANCELLING AS A COURTESY DUE TO COMMUNICATION WITH INSPECTOR. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.***
ROW - FINAL APRON (AFTER POUR) 10/29/2025 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** 10/29/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.***
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/28/2025 APPROVED FSLADISH
Note: 10/23/2025 - PREVIOUS INSPECTION NOTES ** 10/23/25 LEFT SIDE PROPERTY LINE YOUR FINAL SURVEY SHOWS YOUR WATER DRAINING ONTO THE ADJACENT PROPERTY ** 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16
ROW FIELD SURVEY /GRADING CERTIFICATION 10/28/2025 APPROVED - AS NOTED FSLADISH
Note: 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.***
ROW - DRAINAGE 10/28/2025 APPROVED - AS NOTED FSLADISH
Note: 10/28/25 SPOKE WITH CM PREVIOUSLY AND AS HE WAS CLOSE TO FINAL GRADE DECIDED TO ALLOW HIM TO MOVE FORWARD WITHOUT RESETTING SILT FENCE. ALL TRASH AND DERIS HAS BEEN PICKED UP AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. _________________________________________________________________________________________________________________________ 10/16/2025 - PREVIOUS INSPECTION NOTES 10/16/25 NO CHANGES AT THE TIME OF THIS INSPECTION. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/23/2025 Disapproved - NO FEE EMADISON
Note: ** 10/23/25 LEFT SIDE PROPERTY LINE YOUR FINAL SURVEY SHOWS YOUR WATER DRAINING ONTO THE ADJACENT PROPERTY ** 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16
ROW - DRAINAGE 10/16/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 10/16/25 NO CHANGES AT THE TIME OF THIS INSPECTION. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 10/14/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 10/09/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ELECTRIC - EARLY POWER 10/08/2025 Approval - Private Provider PPROVIDER
ROW - DRAINAGE 10/07/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day.
ROW - DRAINAGE 10/01/2025 Disapproved - NO FEE FSLADISH
Note: 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. PHOTO FOR REFERENCE.
GRAVITY SEWER TEST 08/21/2025 Approval - Private Provider PPROVIDER
SEWER TIE IN 08/21/2025 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 08/20/2025 APPROVED FSLADISH
Note: 8/20/25 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9271 8/7/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 08/07/2025 APPROVED - AS NOTED FSLADISH
Note: 8/7/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 08/07/2025 Disapproved - NO FEE FSLADISH
Note: 8/7/25 SPOKE WITH BUILDER AND LET HIM KNOW APRON WINGS ARE TO BE 36".
ROW- PRE-APRON (PRE-POUR) 08/07/2025 PARTIALLY APPROVED FSLADISH
Note: 8/7/25 RETURNED TO THIS ADDRESS AND MET CM AND CONCRETE SUB. AFTER PULLING A STRING LINE DETERMINED THAT THE APRON WINGS ARE INDEED 36". THE ANGLE OF THE HOUSE ON THE LOT AND CURVE OF THE ROAD CREATED AN OPTICAL ILLUSION. PARTIALLY APPROVING AS NOTED. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 8/7/2025 - PREVIOUS INSPECTION NOTES 8/7/25 SPOKE WITH BUILDER AND LET HIM KNOW APRON WINGS ARE TO BE 36".
DRYWALL NAILING 07/16/2025 Approval - Private Provider PPROVIDER
ROOF IN PROGRESS- MIDROOF 07/10/2025 CANCELLED BY INSPECTOR BBEMBRY
GRAVITY SEWER TEST 07/10/2025 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 06/27/2025 Approval - Private Provider PPROVIDER
INSULATION 06/27/2025 Approval - Private Provider PPROVIDER
ALL ROUGH 06/26/2025 Approval - Private Provider PPROVIDER
Note: 6/16/2025 12:09:25 PM- PREVIOUS INSPECTION NOTES 6/13/2025 12:38:59 PM- PREVIOUS INSPECTION NOTES
ALL ROUGH 06/16/2025 Disapproved- Private Provider PPROVIDER
Note: 6/13/2025 12:38:59 PM- PREVIOUS INSPECTION NOTES
ALL ROUGH 06/12/2025 Disapproved- Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 06/06/2025 APPROVED RRICKS
WALL SHEATHING 05/08/2025 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/08/2025 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 05/08/2025 Approval - Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 05/07/2025 APPROVED AMOBLEY
ELECTRIC-TUG 04/22/2025 Approval - Private Provider PPROVIDER
TIE BEAM / LINTEL 04/14/2025 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 03/27/2025 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 03/21/2025 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 03/21/2025 Approval - Private Provider PPROVIDER
WATER METER INSTALLATION REQUEST 02/26/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ZON COMPLETE 06/06/2025 06/06/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/06/2025 06/06/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 06/02/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/02/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 06/02/2025 06/02/2025
Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM
SW1 HOLD 05/22/2025 05/28/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Per COPC Technical Manual there shall when proposing common swales there shall be a minimum of 0.2' fall from the side property line to the toe of the slope. When common swale cannot be achieved then interior swales are allowed to ensure the adjacent lots are not negatively impacted. In the back yard there is only an 0.1' fall (11.3' to 11.2 and 11.0' 10.9). Please revise.
ENGIN1 COMPLETE 05/22/2025 05/28/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 05/22/2025 05/22/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 05/20/2025 05/21/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Between lot 84 and 83 there are missing elevations. Towards the front of the yard there is a 10.7' beyond the property line, please provide a proposed elevation and an existing elevations at the property line to clearly depict what the drainage. Additionally, there is a proposed elevation of 11.2' in the back that is missing an existing and 10' shot elevation beyond the property line. Note: Common swales are preferred when applicable, when a common swale cannot be achieved inside property swales or berms are acceptable. Please feel free to email or call 386-986-4726 if there are any questions or concerns.
ENGIN1 COMPLETE 05/20/2025 05/21/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 05/20/2025 05/20/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 05/12/2025 05/16/2025
Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM - Based on proposed elevations this lot is negatively impacting improved lot # 83. When proposing common swales or inside v swales there shall be a minimum of 0.2' fall from the top of the swale to the toe of the slope.
ENGIN1 COMPLETE 05/12/2025 05/19/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 05/12/2025 05/12/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 05/08/2025 05/08/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) THE SITE PLAN NEED TO HAVE 10' OFF ELEVATIONS IN THE ADJACENT LOTS. 2) AFTER FUTHER REVIEW THE FFE IS OUT OF TOLERANCE WITH THE FRIST PROPOSED ELEVATION. 3) ALSO AFTER FUTHER REVIEW YOU WILL NEED TO HAVE PROPOSED ELEVATIONS ON THE ALL FOUR CORNER OF THE STRUCTURE AND IN THE MIDDLE OF THE STUCTURE.
ZON COMPLETE 05/02/2025 05/02/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/02/2025 05/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 05/02/2025 05/07/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) NEED TO HAVE A BENCHMARK ON SITE. 2) NEED TO HAVE ELEVATIONS ON ALL ADJACENT LOTS 10' INSIDE THE PROPERTY LINE SO WE CAN SEE IF DRAINAGE WILL IMPACT SURROUND LOTS.
BADMIN INFORMATION 04/30/2025 04/30/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please make revision on a site plan and submit
ENGIN1 COMPLETE 04/30/2025 04/30/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
SW1 HOLD 04/30/2025 04/30/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM FFE on foundation survey is 0.5' higher than what was approved.
ZON COMPLETE 04/30/2025 04/30/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 HOLD 04/30/2025 04/30/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM FFE on foundation survey is more than 0.2' than approved site plan.
ENGIN1 COMPLETE 02/14/2025 02/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 02/11/2025 02/11/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 02/11/2025 02/18/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 HOLD 02/11/2025 02/12/2025
Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please address comments made by zoning,
BADMIN COMPLETE 02/07/2025 02/07/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
URB COMPLETE 02/03/2025 02/04/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BADMIN HOLD 01/30/2025 02/05/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Geotech report is for the wrong address.
CUSVC COMPLETE 01/30/2025 01/31/2025
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
LOCATE COMPLETE 01/30/2025 02/03/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 COMPLETE 01/30/2025 01/30/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 01/30/2025 02/03/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM 1.Site plan Provide the width of the walkway 2.Driveway minimum of 16' wide proposed is currently 9' 16 ft min: 2.Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet. 3. AC pad in a platted 5' Drainage Easement. 4. Map panel # should have two 0143E & 0231E

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤514.49 11/17/2025
WATER- TURN ON ¤25.00 11/17/2025
WATER -IRRIGATION INSPECTION ¤25.00 11/17/2025
REINSPECTION FEE ¤40.00 11/17/2025
RSI REINSPECTION 1 ¤35.00 11/17/2025
RSI REINSPECTION 1 ¤35.00 11/17/2025
RSI REINSPECTION 2 ¤75.00 11/17/2025
SW ENG - INSPECTION 20 ¤20.00 11/17/2025
SW ENG - INSPECTION 20 ¤20.00 11/17/2025
SW ENG - INSPECTION 20 ¤20.00 11/17/2025
SW ENG INSPECTION 80 ¤80.00 02/24/2025
SW ENG PRE APRON ¤30.00 02/24/2025
SW ENG - REVIEW 20 ¤20.00 02/24/2025
SW ENG RES REVIEW 200 ¤200.00 02/24/2025
SEWER INSPECTION ¤25.00 02/24/2025
SEWER CAPITAL FACILITY ¤2,924.57 02/24/2025
WATER CAPITAL FACILITY FEE ¤2,731.83 02/24/2025
SITE PLAN 30 ¤30.00 02/24/2025
WATER-METER ¤514.49 02/24/2025
SURCHARGE FS 533.721 ¤2.00 02/24/2025
SURCHARGE - FS 468.631 ¤2.00 02/24/2025
SW ENG - FOUNDATION SURVEY ¤20.00 02/24/2025
ADJUSTMENT 10% (¤3.00) 02/24/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/24/2025
ADMINISTRATIVE - RESID PP ¤225.00 02/24/2025
CONNECTION FEES ¤25.00 02/24/2025
FC IMPACT FEE EMS ¤62.00 02/24/2025
IMPACT FEE FIRE ¤434.51 02/24/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/24/2025
FC IMPACT FEE LIBRARY ¤268.00 02/24/2025
IMPACT FEE PARKS ¤1,828.01 02/24/2025
IMPACT FEE SCHOOL ¤5,450.00 02/24/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 02/24/2025
Fees Total Due: ¤0.00 Total Paid: ¤19,428.90