I want to search for...
Permit #2025011292
Permit Details
Status: COED
| Parcel Id: 35-11-31-4075-00000-0840 |
| CONDITIONED SPACE: 2968 sqft |
| GARAGE: 760 sqft |
| OPENED PORCH (WITH ROOF) : 584 sqft |
| Total Square Footage: 4312 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: (386)566-3290 |
| Location Address: 33 DEL PALMA DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/24/2025 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: WHELAN JAMES & HEIDI H&W |
|
Address 2823 W PAINTED CANYON WAY HIGHLANDS RANCH, CO 80129 |
| Lot: 0840 |
| Contracted Stated Job Value: ¤450,000.00 |
| Job Description: single family residence. |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BERT S MCLAUGHLIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13006455 (Exp: 08/31/2026) | 386-265-2687 |
JEFFREY R SHELTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6260 WESTVIEW DR, STE 200 ORLANDO, FL 32824 |
LQ3517 (Exp: 07/23/2027) | 301-302-8053 |
RICHARD LEE VONBROCKEN
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1738 STATE AVE HOLLY HILL, FL 32117 |
CAC035516 (Exp: 08/31/2026) | (386)672-1950 | (386)672-1952 |
PEDRO DANIEL CHINCHILLA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
324 COVENT GARDENS PL DELTONA, FL 32725 |
CCC1333997 (Exp: 08/31/2026) | 386-679-6228 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/20/2025 | Approval - Private Provider | PPROVIDER |
| Note: 11/13/2025 12:52:29 PM- PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 11/13/2025 | Disapproved- Private Provider | PPROVIDER |
| U -UTILITY RESIDENTIAL FINAL | 11/13/2025 | FINAL APPROVED | BHAINES |
| Note: 11/7/2025 - PREVIOUS INSPECTION NOTES unable to locate sewer clean out/remove hose bib from water meter assembly-make sure residence has water service | |||
| ROW - STORMWATER FINAL | 11/07/2025 | APPROVED | FSLADISH |
| Note: 11/7/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________--- 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25 SPOKE WITH CM AND LET HIM KNOW SINCE JULY 1ST WHAT OUR NEW REQUIREMENTS WITH REGARD TO EROSION CONTROL FOR ANY DISTURBED AREAS DURING CONSTRUCTION ARE. HE IS GOING TO LAY SOD ON THE BARE AREA IN REAR AND 10' ON THE VACANT LOT ON RIGHT SIDE TO CONTROL EROSION. CANCELLING AS A COURTESY DUE TO COMMUNICATION WITH INSPECTOR. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** | |||
| U -UTILITY RESIDENTIAL FINAL | 11/07/2025 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: unable to locate sewer clean out/remove hose bib from water meter assembly-make sure residence has water service | |||
| U-CROSS CONNECTION | 11/07/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: irrigatiion meter=no cc | |||
| ROW - STORMWATER FINAL | 10/30/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 10/30/25 SPOKE WITH CM AND LET HIM KNOW SINCE JULY 1ST WHAT OUR NEW REQUIREMENTS WITH REGARD TO EROSION CONTROL FOR ANY DISTURBED AREAS DURING CONSTRUCTION ARE. HE IS GOING TO LAY SOD ON THE BARE AREA IN REAR AND 10' ON THE VACANT LOT ON RIGHT SIDE TO CONTROL EROSION. CANCELLING AS A COURTESY DUE TO COMMUNICATION WITH INSPECTOR. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** | |||
| ROW - FINAL APRON (AFTER POUR) | 10/29/2025 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** 10/29/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/28/2025 | APPROVED | FSLADISH |
| Note: 10/23/2025 - PREVIOUS INSPECTION NOTES ** 10/23/25 LEFT SIDE PROPERTY LINE YOUR FINAL SURVEY SHOWS YOUR WATER DRAINING ONTO THE ADJACENT PROPERTY ** 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/28/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/28/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO SOD BARE AREA BEHIND REAR PROPERTY LINE. YOU ARE REQUIRED TO INSTALL A SITL FENCE ALONG THE LEFT SIDE PROPERTY LINE WHERE IT HAS BEEN DISTURBED DURING CONSTUCTION ACTIVITY BEFORE ROW FINAL PASSAGE.*** | |||
| ROW - DRAINAGE | 10/28/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/28/25 SPOKE WITH CM PREVIOUSLY AND AS HE WAS CLOSE TO FINAL GRADE DECIDED TO ALLOW HIM TO MOVE FORWARD WITHOUT RESETTING SILT FENCE. ALL TRASH AND DERIS HAS BEEN PICKED UP AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. _________________________________________________________________________________________________________________________ 10/16/2025 - PREVIOUS INSPECTION NOTES 10/16/25 NO CHANGES AT THE TIME OF THIS INSPECTION. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/23/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 10/23/25 LEFT SIDE PROPERTY LINE YOUR FINAL SURVEY SHOWS YOUR WATER DRAINING ONTO THE ADJACENT PROPERTY ** 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 | |||
| ROW - DRAINAGE | 10/16/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/16/25 NO CHANGES AT THE TIME OF THIS INSPECTION. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 10/14/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/14/25 NO CHANGES AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 10/9/2025 - PREVIOUS INSPECTION NOTES 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 10/09/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/9/25 NO CHANGES MADE AT THE TIME OF THIS INSPECTION. BUILDER HAS NOT REACHED OUT WITH ANY COMMUNICATION. PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ 10/7/2025 - PREVIOUS INSPECTION NOTES 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ELECTRIC - EARLY POWER | 10/08/2025 | Approval - Private Provider | PPROVIDER |
| ROW - DRAINAGE | 10/07/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/7/25 NO CHANGES AT THIS TIME. PLEASE READ PREVIOUS INSPECTION NOTES. YOU ARE REQUIRED TO RE-ESTABLISH SILT FECE AROUND THE PERIMETER OF THE CONSTRUCTION SITE WITH THE EXCEPTION OF THE DRIVEWAYS. I WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 10/9/25. 10/1/2025 - PREVIOUS INSPECTION NOTES 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 10/01/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 10/01/25 YOU ARE REQUIRED TO RE-ESTABLISH YOUR SILT FENCE AROUND THE PERIMETER OF YOUR BUILD TO MAINTAIN EROSION CONTROL AND ADVERSE DRAINAGE FROM IMPACTING ADJOINING PROPERTY OR INFILTRATING THE STORMWATER SYSTEM. YOU WILL HAVE 5 CALENDAR DAYS TO MAKE REQUIRED CORRECTION. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/7/25. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. PHOTO FOR REFERENCE. | |||
| GRAVITY SEWER TEST | 08/21/2025 | Approval - Private Provider | PPROVIDER |
| SEWER TIE IN | 08/21/2025 | APPROVED | MGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 08/20/2025 | APPROVED | FSLADISH |
| Note: 8/20/25 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9271 8/7/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PAVER RESTRAINTS | 08/07/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 8/7/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 08/07/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 8/7/25 SPOKE WITH BUILDER AND LET HIM KNOW APRON WINGS ARE TO BE 36". | |||
| ROW- PRE-APRON (PRE-POUR) | 08/07/2025 | PARTIALLY APPROVED | FSLADISH |
| Note: 8/7/25 RETURNED TO THIS ADDRESS AND MET CM AND CONCRETE SUB. AFTER PULLING A STRING LINE DETERMINED THAT THE APRON WINGS ARE INDEED 36". THE ANGLE OF THE HOUSE ON THE LOT AND CURVE OF THE ROAD CREATED AN OPTICAL ILLUSION. PARTIALLY APPROVING AS NOTED. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 8/7/2025 - PREVIOUS INSPECTION NOTES 8/7/25 SPOKE WITH BUILDER AND LET HIM KNOW APRON WINGS ARE TO BE 36". | |||
| DRYWALL NAILING | 07/16/2025 | Approval - Private Provider | PPROVIDER |
| ROOF IN PROGRESS- MIDROOF | 07/10/2025 | CANCELLED BY INSPECTOR | BBEMBRY |
| GRAVITY SEWER TEST | 07/10/2025 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 06/27/2025 | Approval - Private Provider | PPROVIDER |
| INSULATION | 06/27/2025 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 06/26/2025 | Approval - Private Provider | PPROVIDER |
| Note: 6/16/2025 12:09:25 PM- PREVIOUS INSPECTION NOTES 6/13/2025 12:38:59 PM- PREVIOUS INSPECTION NOTES | |||
| ALL ROUGH | 06/16/2025 | Disapproved- Private Provider | PPROVIDER |
| Note: 6/13/2025 12:38:59 PM- PREVIOUS INSPECTION NOTES | |||
| ALL ROUGH | 06/12/2025 | Disapproved- Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 06/06/2025 | APPROVED | RRICKS |
| WALL SHEATHING | 05/08/2025 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/08/2025 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 05/08/2025 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 05/07/2025 | APPROVED | AMOBLEY |
| ELECTRIC-TUG | 04/22/2025 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 04/14/2025 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 03/27/2025 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/21/2025 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/21/2025 | Approval - Private Provider | PPROVIDER |
| WATER METER INSTALLATION REQUEST | 02/26/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 06/06/2025 | 06/06/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/06/2025 | 06/06/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/02/2025 | 06/02/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/02/2025 | 06/02/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/02/2025 | 06/02/2025 |
| Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/22/2025 | 05/28/2025 |
| Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Per COPC Technical Manual there shall when proposing common swales there shall be a minimum of 0.2' fall from the side property line to the toe of the slope. When common swale cannot be achieved then interior swales are allowed to ensure the adjacent lots are not negatively impacted. In the back yard there is only an 0.1' fall (11.3' to 11.2 and 11.0' 10.9). Please revise. | |||
| ENGIN1 | COMPLETE | 05/22/2025 | 05/28/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/22/2025 | 05/22/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/20/2025 | 05/21/2025 |
| Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM Between lot 84 and 83 there are missing elevations. Towards the front of the yard there is a 10.7' beyond the property line, please provide a proposed elevation and an existing elevations at the property line to clearly depict what the drainage. Additionally, there is a proposed elevation of 11.2' in the back that is missing an existing and 10' shot elevation beyond the property line. Note: Common swales are preferred when applicable, when a common swale cannot be achieved inside property swales or berms are acceptable. Please feel free to email or call 386-986-4726 if there are any questions or concerns. | |||
| ENGIN1 | COMPLETE | 05/20/2025 | 05/21/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/20/2025 | 05/20/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/12/2025 | 05/16/2025 |
| Note: Held By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM - Based on proposed elevations this lot is negatively impacting improved lot # 83. When proposing common swales or inside v swales there shall be a minimum of 0.2' fall from the top of the swale to the toe of the slope. | |||
| ENGIN1 | COMPLETE | 05/12/2025 | 05/19/2025 |
| Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/12/2025 | 05/12/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/08/2025 | 05/08/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) THE SITE PLAN NEED TO HAVE 10' OFF ELEVATIONS IN THE ADJACENT LOTS. 2) AFTER FUTHER REVIEW THE FFE IS OUT OF TOLERANCE WITH THE FRIST PROPOSED ELEVATION. 3) ALSO AFTER FUTHER REVIEW YOU WILL NEED TO HAVE PROPOSED ELEVATIONS ON THE ALL FOUR CORNER OF THE STRUCTURE AND IN THE MIDDLE OF THE STUCTURE. | |||
| ZON | COMPLETE | 05/02/2025 | 05/02/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/02/2025 | 05/06/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/02/2025 | 05/07/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) NEED TO HAVE A BENCHMARK ON SITE. 2) NEED TO HAVE ELEVATIONS ON ALL ADJACENT LOTS 10' INSIDE THE PROPERTY LINE SO WE CAN SEE IF DRAINAGE WILL IMPACT SURROUND LOTS. | |||
| BADMIN | INFORMATION | 04/30/2025 | 04/30/2025 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please make revision on a site plan and submit | |||
| ENGIN1 | COMPLETE | 04/30/2025 | 04/30/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/30/2025 | 04/30/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM FFE on foundation survey is 0.5' higher than what was approved. | |||
| ZON | COMPLETE | 04/30/2025 | 04/30/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 04/30/2025 | 04/30/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM FFE on foundation survey is more than 0.2' than approved site plan. | |||
| ENGIN1 | COMPLETE | 02/14/2025 | 02/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/11/2025 | 02/11/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/11/2025 | 02/18/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 02/11/2025 | 02/12/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please address comments made by zoning, | |||
| BADMIN | COMPLETE | 02/07/2025 | 02/07/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 02/03/2025 | 02/04/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 01/30/2025 | 02/05/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Geotech report is for the wrong address. | |||
| CUSVC | COMPLETE | 01/30/2025 | 01/31/2025 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| LOCATE | COMPLETE | 01/30/2025 | 02/03/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/30/2025 | 01/30/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/30/2025 | 02/03/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM 1.Site plan Provide the width of the walkway 2.Driveway minimum of 16' wide proposed is currently 9' 16 ft min: 2.Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet. 3. AC pad in a platted 5' Drainage Easement. 4. Map panel # should have two 0143E & 0231E |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤514.49 | 11/17/2025 |
| WATER- TURN ON | ¤25.00 | 11/17/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/17/2025 |
| REINSPECTION FEE | ¤40.00 | 11/17/2025 |
| RSI REINSPECTION 1 | ¤35.00 | 11/17/2025 |
| RSI REINSPECTION 1 | ¤35.00 | 11/17/2025 |
| RSI REINSPECTION 2 | ¤75.00 | 11/17/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 11/17/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 11/17/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 11/17/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/24/2025 |
| SW ENG PRE APRON | ¤30.00 | 02/24/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/24/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/24/2025 |
| SEWER INSPECTION | ¤25.00 | 02/24/2025 |
| SEWER CAPITAL FACILITY | ¤2,924.57 | 02/24/2025 |
| WATER CAPITAL FACILITY FEE | ¤2,731.83 | 02/24/2025 |
| SITE PLAN 30 | ¤30.00 | 02/24/2025 |
| WATER-METER | ¤514.49 | 02/24/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/24/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/24/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/24/2025 |
| ADJUSTMENT 10% | (¤3.00) | 02/24/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/24/2025 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 02/24/2025 |
| CONNECTION FEES | ¤25.00 | 02/24/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 02/24/2025 |
| IMPACT FEE FIRE | ¤434.51 | 02/24/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/24/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/24/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 02/24/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 02/24/2025 |
| IMPACT FEE TRANSPORTATION | ¤3,502.00 | 02/24/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,428.90 |