I want to search for...

Permit #2025011372

Permit Details

Status: COED

Parcel Id: 07-11-31-7081-00240-0030
CONDITIONED SPACE: 2430 sqft
GARAGE: 699 sqft
ENCLOSE EXISTING PORCH TO LIVING : 504 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
Total Square Footage: 3729 sqft
Block: 00240
Subdivision: -
Job Phone: 386-627-0430
Location Address: 73 BLARE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/12/2025
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: BARRY MAURICE II & GLORIANNE H&W

Address

36 RIPPLEWOOD LANE

PALM COAST, FL 32164

Lot: 0030
Contracted Stated Job Value: ¤538,000.78
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/24/2025 FINAL APPROVED HCAMACHO
Note: 9/19/2025 - PREVIOUS INSPECTION NOTES 9/19/25 1. Microwave outlet not hooked up. Wire just hanging in cabinet and not even safed off NEC 440.14 2. Energy Calcs need to be changed to show proper AH unit installed. (Breaker is okay) FBC(A) 107.4
BLD - BUILDING FINAL 09/19/2025 Disapproved - NO FEE MCONTRYMAN
Note: 9/19/25 1. Microwave outlet not hooked up. Wire just hanging in cabinet and not even safed off NEC 440.14 2. Energy Calcs need to be changed to show proper AH unit installed. (Breaker is okay) FBC(A) 107.4
U -UTILITY RESIDENTIAL FINAL 09/19/2025 FINAL APPROVED LFITZGERALD
Note: New inspection due to canceled inspection 9/16/2025 - PREVIOUS INSPECTION NOTES liower sewer clean out flush with sod
U -UTILITY RESIDENTIAL FINAL 09/18/2025 CANCELLED BY APPLICANT WEB
Note: 9/16/2025 - PREVIOUS INSPECTION NOTES liower sewer clean out flush with sod
BLD - BUILDING FINAL 09/18/2025 CANCELLED BY APPLICANT WEB
U-CROSS CONNECTION 09/16/2025 APPROVED - AS NOTED LFITZGERALD
Note: NO IRR-NO CC
U -UTILITY RESIDENTIAL FINAL 09/16/2025 Disapproved -FEE REQUIRED LFITZGERALD
Note: liower sewer clean out flush with sod
ROW - STORMWATER FINAL 08/28/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 08/28/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/15/2025 APPROVED FSLADISH
Note: 8/13/2025 - PREVIOUS INSPECTION NOTES 8/13/25 YOUR FINAL SURVEY SHOWS THAT YOU INSTALLED A 12" CMP CULVERT PIPE. YOUR SITE PLAN SHOWS A 13" X 17" CMP CULVERT PIPE WHICH IS THE CORRECT COPC STANDARD SIZE. PLEASE CHECK TO SEE IF THIS IS A TYPO OR 12" CMP WAS INSTALLED. 12" CMP IS NOT ALLOWED. PLEASE INDICATE WITH AN X ON YOUR SURVEY THE LOCATION OF THE ELEVATION SHOT. Type and size of culvert pipe to be installed must be indicated on plans. Sec.300.01 c1 V-15 "Type and size of culvert pipe to be installed must be indicated on plans. Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram"
ROW FIELD SURVEY /GRADING CERTIFICATION 08/15/2025 APPROVED - AS NOTED FSLADISH
Note: 8/15/25 UPON WALKING PROPERTY DRAINAGE IN GENERAL WILL WORK. THE YARD AND SWALE WILL NEED TO BE MOWED AS THEY ARE TOO DEEP IN ORDER TO MAKE A FINAL GRADE DETERMINATION BEFORE ROW FINAL PASSAGE. I AM APPROVING THIS FIELD SURVEY AS NOTED AND A COURTESY SO THAT YOU MAY MOVE FORWARD WITH INSPECTIONS. 15-108 (d) is the code; it does not specify an actual height in inches; overgrown conditions are also covered in 35-76 (d)(2) under nuisances, again not specifying an exact height in inches. This is how the code defines it…. Excessive growth of grass, weeds, or brush and other overgrowth means grass or weeds or brush, bushes, shrubs, trees, vines, or flowering plants, and different living plant life that is allowed to grow in a wild and unkempt manner not in keeping with the neighborhood.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/13/2025 Disapproved - NO FEE FSLADISH
Note: 8/13/25 YOUR FINAL SURVEY SHOWS THAT YOU INSTALLED A 12" CMP CULVERT PIPE. YOUR SITE PLAN SHOWS A 13" X 17" CMP CULVERT PIPE WHICH IS THE CORRECT COPC STANDARD SIZE. PLEASE CHECK TO SEE IF THIS IS A TYPO OR 12" CMP WAS INSTALLED. 12" CMP IS NOT ALLOWED. PLEASE INDICATE WITH AN X ON YOUR SURVEY THE LOCATION OF THE ELEVATION SHOT. Type and size of culvert pipe to be installed must be indicated on plans. Sec.300.01 c1 V-15 "Type and size of culvert pipe to be installed must be indicated on plans. Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram"
GRAVITY SEWER TEST 06/25/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET, FBC3303.5 SWALE BLOCKED BY PORTABLE RESTROOM
SEWER TIE IN 06/25/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET, FBC3303.5 SWALE BLOCKED BY PORTABLE RESTROOM
ROW- PRE-APRON (PRE-POUR) 06/11/2025 APPROVED PFLANAGAN
Note: CORRECTION MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ------------------------------------------------------------------------ 6/9/2025 - PREVIOUS INSPECTION NOTES THERE IS NO SITE PLAN ON FILE IN THE PERMIT NEED TO HAVE THE SITE PLAN SO WE CAN INSPECT DRIVEWAY CORRECTLY
ROW- PRE-APRON (PRE-POUR) 06/09/2025 Disapproved - NO FEE PFLANAGAN
Note: THERE IS NO SITE PLAN ON FILE IN THE PERMIT NEED TO HAVE THE SITE PLAN SO WE CAN INSPECT DRIVEWAY CORRECTLY
ELECTRIC - EARLY POWER 06/06/2025 APPROVED - AS NOTED KSANDOE
INSULATION 05/06/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 4/30/25 Will check at insulation 1. Missing required strap for dryer vent pipe 2. Missing low voltage box 3. Duct layout does not match what is installed. Please have revised and approved plans by next inspection FBC(A) 107.4
ALL ROUGH 04/30/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 4/30/25 Will check at insulation 1. Missing required strap for dryer vent pipe 2. Missing low voltage box 3. Duct layout does not match what is installed. Please have revised and approved plans by next inspection FBC(A) 107.4
LATH/BRICK/ WATER BARRIER 04/24/2025 APPROVED HCAMACHO
WALL SHEATHING 04/16/2025 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/16/2025 APPROVED FWILLIS
ROOF VALLEY & METAL 04/16/2025 APPROVED FWILLIS
ELECTRIC-TUG 04/09/2025 APPROVED HCAMACHO
TIE BEAM / LINTEL 04/02/2025 APPROVED HCAMACHO
FOUND SURVEY APPROVED (OFFICE) 03/28/2025 APPROVED RRICKS
MONOLITHIC SLAB 03/17/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 3/17/25 1. Need permit posted in box FBC 105.7
PLUMBING 1ST ROUGH UNDERGROUND 03/12/2025 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET, FBC3303.5 SWALE BLOCKED BY PORTABLE RESTROOM
PLUMBING 1ST ROUGH UNDERGROUND 03/11/2025 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 03/11/2025 CANCELLED BY APPLICANT WEB
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/06/2025 APPROVED KSANDOE
WATER METER INSTALLATION REQUEST 02/28/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 09/22/2025 09/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2025 09/05/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Per change to LDC - no more regulations on blue paint colors.
ZON HOLD 06/09/2025 06/09/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Color submitted is not an approved color per Land Development Code.
ENGIN1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 05/29/2025 05/29/2025
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Color submitted is not an approved color per Land Development Code.
MECH COMPLETE 05/02/2025 05/05/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/28/2025 03/28/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2025 03/28/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 03/06/2025 03/06/2025
Note: Released By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM
BADMIN INFORMATION 02/20/2025 02/20/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC not legible.
MECH COMPLETE 02/12/2025 02/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/12/2025 02/12/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 02/10/2025 02/11/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Woorksheet Please provide product approval # for shingles.
MECH HOLD 02/10/2025 02/11/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide updated state card
ZON COMPLETE 02/10/2025 02/10/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM It is shown on building page 2
SWALE COMPLETE 02/03/2025 02/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 01/31/2025 02/05/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 01/31/2025 02/05/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing worksheet 1. FL# 5444-R17 out of cycle. We are in the 2023 code cycle. 2. FL# 6785-R10 out of cycle. Product Approval Form 1. FL# 5444-17 out of cycle. 2. FL# 4103-R11 out of cycle. 3. FL# 13872-R4 out of cycle. 4. FL# 11473-R4 out of cycle. 5. FL# 15363-R2 out of cycle. 6. FL# 158-R12 out of cycle.
CUSVC COMPLETE 01/31/2025 02/04/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/31/2025 02/05/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/31/2025 02/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 01/31/2025 02/04/2025
LOCATE COMPLETE 01/31/2025 02/04/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 01/31/2025 02/05/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy calcs show 15 seer 2. The heatload shows 14.3 seer2. The AHRI shows 40,500 and the Energy calc shows 42000. Provide correct equipment on heatload. 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
SW1 COMPLETE 01/31/2025 02/04/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 01/31/2025 02/03/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM landscape this property requires two shade trees, please swap out one of the shade trees in the back and place it out front. As the code states the shade tree should be in perferably front yard. Elevation plan Left side missing please provide

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/23/2025
REINSPECTION FEE ¤40.00 09/23/2025
SURCHARGE FS 533.721 ¤17.39 02/12/2025
SURCHARGE - FS 468.631 ¤26.09 02/12/2025
SW ENG - FOUNDATION SURVEY ¤20.00 02/12/2025
SW ENG INSPECTION 80 ¤80.00 02/12/2025
SW ENG PRE APRON ¤30.00 02/12/2025
SW ENG - REVIEW 20 ¤20.00 02/12/2025
SW ENG RES REVIEW 200 ¤200.00 02/12/2025
SEWER CREDIT (¤1,390.00) 02/12/2025
SEWER INSPECTION ¤25.00 02/12/2025
SEWER CAPITAL FACILITY ¤6,120.52 02/12/2025
WATER CREDIT (¤1,733.75) 02/12/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 02/12/2025
SITE PLAN 30 ¤30.00 02/12/2025
CONNECTION FEES ¤1,187.26 02/12/2025
FC IMPACT FEE EMS ¤62.00 02/12/2025
IMPACT FEE FIRE ¤434.51 02/12/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/12/2025
FC IMPACT FEE LIBRARY ¤268.00 02/12/2025
IMPACT FEE PARKS ¤1,828.01 02/12/2025
IMPACT FEE SCHOOL ¤5,450.00 02/12/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 02/12/2025
WATER -IRRIGATION INSPECTION ¤25.00 02/12/2025
WATER -IRRIGATION INSPECTION ¤25.00 02/12/2025
WATER-METER ¤514.49 02/12/2025
WATER- TURN ON ¤25.00 02/12/2025
WATER- TURN ON ¤25.00 02/12/2025
ADJUSTMENT 10% (¤193.27) 02/12/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/12/2025
INSPECTION - RESIDENTIAL ¤1,482.25 02/12/2025
PLAN REVIEW - RESIDENTIAL ¤420.42 02/12/2025
Fees Total Due: ¤0.00 Total Paid: ¤21,586.56