Permit #2025020007

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7030-00600-0010
Total Square Footage: 3020 sqft
Block: 00600
Subdivision: -
Job Phone: 717-307-6845
Location Address: 11 RANBAY PL
Type: DR - DRIVEWAY
Issue Date: 02/10/2025
NOC: RECORDED
Applicant name: JARRETT D LEHMAN
Owner: MILLS WILLIAM S

Address

11 RANBAY PLACE

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤10,800.00
Job Description: Remove and replace driveway and culvert
Type: CN

Contractor

SALT FORCE CONCRETE & OUTDOOR CUSTOMS INC
Status Location Address Phone
CANCEL

9979 AMOS AVE

HASTINGS, FL 32145

386-302-3262

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 03/28/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 03/28/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 03/28/2025 FINAL APPROVED LFITZGERALD
ROW- PRE-APRON (PRE-POUR) 03/14/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/3/2025 - PREVIOUS INSPECTION NOTES ** 03/03/25 BUILDER NEEDS TO HAVE A SWALE PLAN DIAGRAM WITH THE BENCH MARK AS TO THE CULVERTS ELEVATION PROVIDED BY THE CITY OF PALM COAST. ** SEE DRAWING 300E IN THE COPC TECHNIQUAL MANUAL ATTACHED IN PHOTO FOR INSPECTION ** MITERED ENDS NEED TO HAVE A FOOTER DUG THAT IS 6"X6"X18" THAT EXTENDS A INIMUM OF 3 INCHES UNDER THE END OF THE CULVERT ** FORM BOARDS AT AT MITERED ENDS NEED TO BE AT A MINIMUM 0F 18" AT THE TOP OF MITERED END 9" AT THE LOWEST POINT AT THE MITERED END OF CULVERT. ** DRIVEWAY ABOVE THE (ROW) RIGHT OF WAY NEEDS TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE ** BUILDING DEPT. APPROVED THAT THE WATER METER BOX CAN STAY WHERE IT IS LOCATED AS HOMEOWNER WILL ASSUME ANY RESPOSIBILITY IF DAMAGE OCCURS TO IT.
ROW- PRE-APRON (PRE-POUR) 03/03/2025 Disapproved - NO FEE EMADISON
Note: ** 03/03/25 BUILDER NEEDS TO HAVE A SWALE PLAN DIAGRAM WITH THE BENCH MARK AS TO THE CULVERTS ELEVATION PROVIDED BY THE CITY OF PALM COAST. ** SEE DRAWING 300E IN THE COPC TECHNIQUAL MANUAL ATTACHED IN PHOTO FOR INSPECTION ** MITERED ENDS NEED TO HAVE A FOOTER DUG THAT IS 6"X6"X18" THAT EXTENDS A INIMUM OF 3 INCHES UNDER THE END OF THE CULVERT ** FORM BOARDS AT AT MITERED ENDS NEED TO BE AT A MINIMUM 0F 18" AT THE TOP OF MITERED END 9" AT THE LOWEST POINT AT THE MITERED END OF CULVERT. ** DRIVEWAY ABOVE THE (ROW) RIGHT OF WAY NEEDS TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE ** BUILDING DEPT. APPROVED THAT THE WATER METER BOX CAN STAY WHERE IT IS LOCATED AS HOMEOWNER WILL ASSUME ANY RESPOSIBILITY IF DAMAGE OCCURS TO IT.

Review History

Department Status Date In Date Out
SWALE COMPLETE 03/04/2025 03/04/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/03/2025 02/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
UTL COMPLETE 02/03/2025 02/10/2025
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 02/03/2025 02/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤20.00 03/27/2025
ADJUSTMENT 10% (¤3.00) 02/10/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/10/2025
SW ENG INSPECTION 40 ¤40.00 02/10/2025
SW ENG PRE APRON ¤30.00 02/10/2025
SW ENG RES REVIEW 200 ¤200.00 02/10/2025
SITE PLAN 15 ¤15.00 02/10/2025
Fees Total Due: ¤0.00 Total Paid: ¤332.00