Permit #2025020393
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00370-0250 |
| Block: 00370 |
| Subdivision: 7023 - |
| Job Phone: 717-307-6845 |
| Location Address: 15 WHITE HAVEN LN |
| Type: DR - DRIVEWAY |
| Issue Date: 03/24/2025 |
| NOC: Unknown |
| Applicant name: JARRETT D LEHMAN |
| Owner: BERTOLA GABRIEL & ILEANA BERTOLA H&W |
|
Address 15 WHITE HAVEN LANE PALM COAST, FL 32164 |
| Lot: 0250 |
| Contracted Stated Job Value: ¤2,475.00 |
| Job Description: Partial Driveway Replacement |
| Type: CN |
Contractor
SALT FORCE CONCRETE & OUTDOOR CUSTOMS INC
| Status | Location Address | Phone |
| CANCEL |
9979 AMOS AVE HASTINGS, FL 32145 |
386-302-3262 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 04/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9270 03/25/25 TPOLACEK*** PLEASE DIG FOOTERS TO 6" DEEP BEFORE POURING AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ROW - FINAL INSPECTION | 04/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9270 03/25/25 TPOLACEK*** PLEASE DIG FOOTERS TO 6" DEEP BEFORE POURING AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| U -UTILITY RESIDENTIAL FINAL | 04/16/2025 | FINAL APPROVED | DHANEY |
| ROW- PRE-APRON (PRE-POUR) | 03/25/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 03/25/25 TPOLACEK*** PLEASE DIG FOOTERS TO 6" DEEP BEFORE POURING AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 03/19/2025 | 03/19/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/11/2025 | 02/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 02/10/2025 | 02/11/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please show on the site plan the type and size of culvert, 13"x17"CMP, 15" CMP, or 15" HDPE. | |||
| UTL | COMPLETE | 02/10/2025 | 02/18/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/10/2025 | 02/10/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 03/24/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/24/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 03/24/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/24/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/24/2025 |
| SITE PLAN 15 | ¤15.00 | 03/24/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤312.00 |