I want to search for...
Permit #2025020418
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7006-00040-0060 |
| Total Square Footage: 400 sqft |
| Block: 00040 |
| Subdivision: - |
| Job Phone: 386-237-5837 |
| Location Address: 12 FLINTSTONE CT |
| Type: DR - DRIVEWAY |
| Issue Date: 03/02/2025 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: RODRIGUES LUCIANO & MARIA H&W |
|
Address 12 FLINTSTONE COURT PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤2,000.00 |
| Job Description: driveway extension and Pavers |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 04/21/2025 | APPROVED | FSLADISH |
| Note: 4/21/25 PREVIOUS INSPECTION REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. __________________________________________________________________________________________________________________________ 4/3/2025 - PREVIOUS INSPECTION NOTES ** 04/03/25 BUILDER NEEDS TO REMOVE ALL OVER POURED CONCRETE OUT OF THE CULVERT | |||
| ROW - FINAL INSPECTION | 04/03/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 04/03/25 BUILDER NEEDS TO REMOVE ALL OVER POURED CONCRETE OUT OF THE CULVERT | |||
| ROW - FINAL APRON (AFTER POUR) | 03/31/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/20/2025 | APPROVED | PFLANAGAN |
| Note: READY FOR PAVERS ------------------------------------------------------------------- 3/14/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR AND NEED TO REMOVE SOME DIRT AT THE EDGE OF ROAD WHERE THE FORM BOARDS ARE TO GIVE THEM MINIMUM OF CONCRETE. READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------- 3/11/2025 - PREVIOUS INSPECTION NOTES 1) THERE IS TOO MUCH WATER IN POURING AREA AND UNDER CULVERT. 2) NEED TO HAVE BOTH MITER END FOOTER DUG OUT TO A MINIMUM OF 6"X6". 3) NEED TO HAVE #4 REBAR ON SITE AT THE WIDTH OF CULVERT PIPE. 4) SOIL IN THE POURING AREA IS TOO SOFT NEED TO LET DRT OUT AND COMPACT SOIL ALONG CULVERT PIPE. 5) YOU DO NOT HAVE PAVER RESTRAINTS / FOOTERS DUG ON SITE YET ALSO YOU DO NOT HAVE A PAVER DETAIL UPLOADED IN THE SYSTEM SO WE CAN INSPECT THE PAVER RESTRAINTS / FOOTERS PROPERLY. ------------------------------------------------------------------------------- 3/10/2025 - PREVIOUS INSPECTION NOTES ** 03/10/25 TOO MUCH WATER IN THE POUR AREA ** SEE ATTACHED PHOTOS | |||
| ROW- PAVER RESTRAINTS | 03/14/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/14/2025 | PARTIALLY APPROVED | PFLANAGAN |
| Note: SPOKE WITH CONTRACTOR AND NEED TO REMOVE SOME DIRT AT THE EDGE OF ROAD WHERE THE FORM BOARDS ARE TO GIVE THEM MINIMUM OF CONCRETE. READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------- 3/11/2025 - PREVIOUS INSPECTION NOTES 1) THERE IS TOO MUCH WATER IN POURING AREA AND UNDER CULVERT. 2) NEED TO HAVE BOTH MITER END FOOTER DUG OUT TO A MINIMUM OF 6"X6". 3) NEED TO HAVE #4 REBAR ON SITE AT THE WIDTH OF CULVERT PIPE. 4) SOIL IN THE POURING AREA IS TOO SOFT NEED TO LET DRT OUT AND COMPACT SOIL ALONG CULVERT PIPE. 5) YOU DO NOT HAVE PAVER RESTRAINTS / FOOTERS DUG ON SITE YET ALSO YOU DO NOT HAVE A PAVER DETAIL UPLOADED IN THE SYSTEM SO WE CAN INSPECT THE PAVER RESTRAINTS / FOOTERS PROPERLY. ------------------------------------------------------------------------------- 3/10/2025 - PREVIOUS INSPECTION NOTES ** 03/10/25 TOO MUCH WATER IN THE POUR AREA ** SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 03/11/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THERE IS TOO MUCH WATER IN POURING AREA AND UNDER CULVERT. 2) NEED TO HAVE BOTH MITER END FOOTER DUG OUT TO A MINIMUM OF 6"X6". 3) NEED TO HAVE #4 REBAR ON SITE AT THE WIDTH OF CULVERT PIPE. 4) SOIL IN THE POURING AREA IS TOO SOFT NEED TO LET DRT OUT AND COMPACT SOIL ALONG CULVERT PIPE. 5) YOU DO NOT HAVE PAVER RESTRAINTS / FOOTERS DUG ON SITE YET ALSO YOU DO NOT HAVE A PAVER DETAIL UPLOADED IN THE SYSTEM SO WE CAN INSPECT THE PAVER RESTRAINTS / FOOTERS PROPERLY. ------------------------------------------------------------------------------- 3/10/2025 - PREVIOUS INSPECTION NOTES ** 03/10/25 TOO MUCH WATER IN THE POUR AREA ** SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 03/10/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 03/10/25 TOO MUCH WATER IN THE POUR AREA ** SEE ATTACHED PHOTOS | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 02/25/2025 | 02/25/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit original Right of Way Utilization Agreement for Paver Driveway. | |||
| ENGIN1 | COMPLETE | 02/25/2025 | 02/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 02/25/2025 | 02/27/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/25/2025 | 02/25/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/24/2025 | 02/24/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM All owners on deed must sign the right of way agreement. Once electronic copy is approved we will ask for original Please provide walkway width on site plan. Drawn at 8ft walkways cannot exceed 6ft. | |||
| ENGIN1 | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/12/2025 | 02/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 02/10/2025 | 02/12/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please show on the site plan the type and size of culvert. 13"x17" CMP, 15" CMP, or 15" HDPE. | |||
| UTL | COMPLETE | 02/10/2025 | 02/18/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/10/2025 | 02/10/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM All owners on deed must sign the right of way agreement. Once electronic copy is approved we will ask for original |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 03/02/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/02/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 03/02/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 03/02/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/02/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/02/2025 |
| SITE PLAN 15 | ¤15.00 | 03/02/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | |
| SW ENG REINSPECTION 30 | ¤30.00 | |
| SW ENG REINSPECTION 30 | ¤30.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤356.00 |