Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01150-0050 |
| CONDITIONED SPACE: 1754 sqft |
| GARAGE: 437 sqft |
| OPENED PORCH (WITH ROOF) : 89 sqft |
| OPENED PORCH (WITH ROOF) : 182 sqft |
| Total Square Footage: 2462 sqft |
| Block: 01150 |
| Subdivision: 7037 - |
| Job Phone: 407-476-8195 |
| Location Address: 34 LEWIS DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/28/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LLC |
|
Address 3670 MAGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address SUITE 220 ORLANDO, FL 32803 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/10/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: 12/9/2025 - PREVIOUS INSPECTION NOTES 12/9/25 1. AH unit heat strips not marked FBCR M1303.1 2. Tub spout in guest bath loose and not caulked correctly 3. Dryer vents needs to be capped off/covered FBC-M1502.4.7 | |||
| BLD - BUILDING FINAL | 12/09/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 12/9/25 1. AH unit heat strips not marked FBCR M1303.1 2. Tub spout in guest bath loose and not caulked correctly 3. Dryer vents needs to be capped off/covered FBC-M1502.4.7 | |||
| U -UTILITY RESIDENTIAL FINAL | 12/08/2025 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 NO IRR/NO CC | |||
| ROW - FINAL APRON (AFTER POUR) | 12/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/05/2025 | APPROVED | TPOLACEK |
| Note: 11/21/2025 - PREVIOUS INSPECTION NOTES 11-21-25 TPOLACEK*** FINAL SURVEY INDICATES DRAINAGE WILL FLOW BACK WELL PASSED THE 10' NOTED IN INSPECTOR NOTE. FINISHED GRADE ON SITE MATCHES NOTES. I HAVE ATTACHED A PHOTO SHOWING THE SHOTS IN QUESTION THAT WILL NEED TO BE RE-SHOT TO SHOW CONDITIONS IN FIELD. THE FRONT SWALE ON THE RIGHT SIDE OF DRIVEWAY MUST BE GRADED SO THE CENTERLINE OF SWALE IS ALIGNED WITH CENTER OF CULVERT. CENTERLINE IS PAINTED WITH PINK PAINT AT THIS TIME. NOTE TO INSPECTOR DRAINAGE PATTERN WILL BE ONLY 10' OFF THE BACK OF THE HOUSE TO MAKE THE GRADE TO THE ADJACENT LOT NOT SO STEEP ANY QUESTIONS CALL PARREN | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/05/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 12/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- PROJECT STATUS | 12/03/2025 | Status Check | PFLANAGAN |
| Note: MEETING WITH INB TO DISCUSS FINAL SURVEY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/21/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-21-25 TPOLACEK*** FINAL SURVEY INDICATES DRAINAGE WILL FLOW BACK WELL PASSED THE 10' NOTED IN INSPECTOR NOTE. FINISHED GRADE ON SITE MATCHES NOTES. I HAVE ATTACHED A PHOTO SHOWING THE SHOTS IN QUESTION THAT WILL NEED TO BE RE-SHOT TO SHOW CONDITIONS IN FIELD. THE FRONT SWALE ON THE RIGHT SIDE OF DRIVEWAY MUST BE GRADED SO THE CENTERLINE OF SWALE IS ALIGNED WITH CENTER OF CULVERT. CENTERLINE IS PAINTED WITH PINK PAINT AT THIS TIME. NOTE TO INSPECTOR DRAINAGE PATTERN WILL BE ONLY 10' OFF THE BACK OF THE HOUSE TO MAKE THE GRADE TO THE ADJACENT LOT NOT SO STEEP ANY QUESTIONS CALL PARREN | |||
| U-CROSS CONNECTION | 11/20/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: NO IRR/NO CC | |||
| ROW- PROJECT STATUS | 10/22/2025 | Status Check | PFLANAGAN |
| Note: ALLOWING INB TO PUT THERE DRAINAGE PATTERN 10' FROM BACK OF THE HOUSE AND NOT 25' OFF THE HOUSE. ----------------------------------------------------------------------------------- MEETING WITH FRANKIE WITH INB FOR GRADING. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/15/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 10/15/25 READY TO POUR ENSURE FOOTERS ARE DUG 6X6X18 BEFORE POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300, E RESIDENTIAL CULVERT DETAIL __________________________________________________________________________________________________________________ 10/14/2025 - PREVIOUS INSPECTION NOTES ** 10/14/25 CANCELLED VIA TEXT MESSAGE FROM FRANKIE __________________________________________________________________________________________________________________ 9/26/2025 - PREVIOUS INSPECTION NOTES ** 0926/25 SITE HAS TOO MUCH WATER IN POUR AREA NOT READY FOR INSPECTION ** SEE ATTACHED PHOTO | |||
| ROW- PRE-APRON (PRE-POUR) | 10/14/2025 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 10/14/25 CANCELLED VIA TEXT MESSAGE FROM FRANKIE __________________________________________________________________________________________________________________ 9/26/2025 - PREVIOUS INSPECTION NOTES ** 0926/25 SITE HAS TOO MUCH WATER IN POUR AREA NOT READY FOR INSPECTION ** SEE ATTACHED PHOTO | |||
| ROW- PRE-APRON (PRE-POUR) | 09/26/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 0926/25 SITE HAS TOO MUCH WATER IN POUR AREA NOT READY FOR INSPECTION ** SEE ATTACHED PHOTO | |||
| ELECTRIC - EARLY POWER | 09/24/2025 | APPROVED | HCAMACHO |
| GRAVITY SEWER TEST | 09/16/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED PORTABLE RESTROOM BY NEXT INSPECTION | |||
| SEWER TIE IN | 09/16/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS AVIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED PORTABLE RESTROOM BY NEXT INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 09/02/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 08/22/2025 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 8/18/2025 2:57:05 PM *** 8/18/25: 1). Wires are not phased out in the panel. NEC 200.6(B) 2). Front door has over the maximum 1/4" shim space. FBCR 609.1 3). Master bedroom & bathroom windows have over 1/4" maximum shim space. FBCR 609.1 4). 5ft head pressure is not holding. FBC-P2503.5.1 | |||
| ELECTRIC-TUG | 08/20/2025 | APPROVED | KSANDOE |
| Note: 8/18/2025 - PREVIOUS INSPECTION NOTES 8/18/28: 1). Aluminum braided ground: all strands need to be secured in the lug as required. NEC-110.14(A). | |||
| ELECTRIC-TUG | 08/18/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/18/2025 3:04:54 PM *** 8/18/28: 1). Aluminum braided ground: all strands need to be secured in the lug as required. NEC-110.14(A). | |||
| LATH/BRICK/ WATER BARRIER | 08/18/2025 | APPROVED | FWILLIS |
| ALL ROUGH | 08/18/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/18/2025 2:57:05 PM *** 8/18/25: 1). Wires are not phased out in the panel. NEC 200.6(B) 2). Front door has over the maximum 1/4" shim space. FBCR 609.1 3). Master bedroom & bathroom windows have over 1/4" maximum shim space. FBCR 609.1 4). 5ft head pressure is not holding. FBC-P2503.5.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/12/2025 | APPROVED | JSTEWART |
| ROOF VALLEY & METAL | 08/12/2025 | APPROVED | JSTEWART |
| ROOF SHEATHING | 08/07/2025 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2340 NOTE: Truss Package onsite (Not covered, directly on ground). Ship date 7/25/25. | |||
| WALL SHEATHING | 08/07/2025 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2340 NOTE: Truss Package onsite (Not covered, directly on ground). Ship date 7/25/25. | |||
| TIE BEAM / LINTEL | 07/29/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: NOTE: Truss Package onsite (Not covered, directly on ground). Ship date 7/25/25. | |||
| MONOLITHIC SLAB | 07/18/2025 | APPROVED | MCONTRYMAN |
| Note: 7/17/2025 - PREVIOUS INSPECTION NOTES Footing and reinforcement needs re worked, thru out. Reinforcement laying on ground (not on chairs), bends in corners to big reinforcment tight to barrier/soil, creating no coverage. FBC R404.1.3.3.7.4 / 7/15/2025 - PREVIOUS INSPECTION NOTES 7/15/25 1. Too much wash-in all around the slab 2. Garage area has a large object/rock under poly. Marked with an orange X --Rebar is good | |||
| MONOLITHIC SLAB | 07/17/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Footing and reinforcement needs re worked, thru out. Reinforcement laying on ground (not on chairs), bends in corners to big reinforcment tight to barrier/soil, creating no coverage. FBC R404.1.3.3.7.4 / 7/15/2025 - PREVIOUS INSPECTION NOTES 7/15/25 1. Too much wash-in all around the slab 2. Garage area has a large object/rock under poly. Marked with an orange X --Rebar is good | |||
| MONOLITHIC SLAB | 07/15/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 7/15/25 1. Too much wash-in all around the slab 2. Garage area has a large object/rock under poly. Marked with an orange X --Rebar is good | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 07/10/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/09/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED PORTABLE RESTROOM BY NEXT INSPECTION | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/02/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 06/17/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/10/2025 | 07/10/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/01/2025 | 07/02/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/28/2025 | 02/28/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/28/2025 | 02/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/28/2025 | 02/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/28/2025 | 03/05/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/12/2025 | 02/19/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/12/2025 | 02/19/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/12/2025 | 02/12/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/12/2025 | 02/19/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/12/2025 | 02/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/12/2025 | 02/14/2025 |
| LOCATE | COMPLETE | 02/12/2025 | 02/18/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/12/2025 | 02/18/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/12/2025 | 02/19/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/12/2025 | 02/12/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM House layout (front entry) on plans do not match site and landscape plans layout Color code of plantings around ac unit on landscape plan show 3 gallon. They must be 7 gallon | |||
| SWALE | COMPLETE | 02/12/2025 | 02/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI GENERAL INSPECTION 32.50 | ¤32.50 | 12/05/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/17/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 11/17/2025 |
| RSI GENERAL INSPECTION 32.50 | ¤32.50 | 11/17/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/28/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/28/2025 |
| SEWER INSPECTION | ¤25.00 | 05/28/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 05/28/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 05/28/2025 |
| SITE PLAN 30 | ¤30.00 | 05/28/2025 |
| CONNECTION FEES | ¤1,187.26 | 05/28/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/28/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/28/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/28/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/28/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/28/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/28/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 05/28/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/28/2025 |
| SURCHARGE FS 533.721 | ¤11.07 | 05/28/2025 |
| SURCHARGE - FS 468.631 | ¤16.61 | 05/28/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/28/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/28/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/28/2025 |
| WATER- TURN ON | ¤25.00 | 05/28/2025 |
| ADJUSTMENT 10% | (¤123.02) | 05/28/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/28/2025 |
| INSPECTION - RESIDENTIAL | ¤935.00 | 05/28/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤265.20 | 05/28/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,560.30 |