I want to search for...
Permit #2025020630
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7013-00020-0500 |
| Block: 00020 |
| Subdivision: - |
| Job Phone: 386-216-9945 |
| Location Address: 60 BRACKEN LN |
| Type: PO - POOL |
| Issue Date: 03/03/2025 |
| NOC: RECORDED |
| Applicant name: CASEY C WATSON |
| Owner: KING KAREN G |
|
Address 60 BRACKEN LANE PALM COAST, FL 32137 |
| Lot: 0500 |
| Contracted Stated Job Value: ¤94,768.00 |
| Job Description: POOL WITH SCREEN ENCLOSURE |
| Type: CN |
Contractor
EXQUISITE POOL & SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3895 BRITTING DR DELAND, FL 32724 |
CPC1457932 (Exp: 08/31/2026) | 386-216-9945 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
JOHN LEROY HODGINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2020 COUNTRY FARMS RD PORT ORANGE, FL 32128 |
CGC1507254 (Exp: 08/31/2026) | 386-547-2998 | 386-788-4028 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 08/07/2025 | FINAL APPROVED | JSTEWART |
| Note: 7/31/2025 - PREVIOUS INSPECTION NOTES 1. Please change the (2) receptacles located in each corner of the pool enclosure to Weather resistant receptacle. NEC 406.9 2. Please change housing on said receptacles to weather proof enclosure while item is plugged into the receptacle, unatteded use. NEC 406.9 (2) (a). | |||
| POOL FINAL | 07/31/2025 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Please change the (2) receptacles located in each corner of the pool enclosure to Weather resistant receptacle. NEC 406.9 2. Please change housing on said receptacles to weather proof enclosure while item is plugged into the receptacle, unatteded use. NEC 406.9 (2) (a). | |||
| U -UTILITY RESIDENTIAL FINAL | 07/30/2025 | FINAL APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/29/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: MET WITH DAVID AND HOMEOWNER ABOUT FINAL SURVEY AND HOMEOWNER STATES NO WATER SITS IN THE BACKYARD FINAL SURVEY STATES THAT THE WATER WILL GET TRAPED BUT PASSING FINAL SURVEY AND FIELD INSPECTION ON HOMEOWNER WORD OF NO WATER SITTING. ---------------------------------------------------------------------------------- 7/28/2025 - PREVIOUS INSPECTION NOTES THE NEW FINAL SURVEY SHOWS THE DRAINAGE BEING TRAPED IN THE BACK AND NOT ALLOWING THE WATER TO FLOW TO THE ROADSIDE SWALES. ----------------------------------------------------------------------------------------- 7/10/2025 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STATES THAT THE DRAINAGE PATTERN IS TO FLAT CITY CODE STATES THAT THE DRAINAGE PATTERN MUST HAVE .10 OF FALL EVERY 20' PLEASE SEE CODE AT Section 300.01 D(4) | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/29/2025 | APPROVED | PFLANAGAN |
| Note: MET WITH DAVID AND HOMEOWNER ABOUT FINAL SURVEY AND HOMEOWNER STATES NO WATER SITS IN THE BACKYARD FINAL SURVEY STATES THAT THE WATER WILL GET TRAPED BUT PASSING FINAL SURVEY AND FIELD INSPECTION ON HOMEOWNER WORD OF NO WATER SITTING. | |||
| ROW - FINAL INSPECTION | 07/29/2025 | APPROVED | PFLANAGAN |
| Note: ALL ROW DAMAGE FIXED AT THIS TIME | |||
| ROW- PROJECT STATUS | 07/29/2025 | Status Check | PFLANAGAN |
| Note: MET WITH DAVID AND HOMEOWNER ABOUT FINAL SURVEY AND HOMEOWNER STATES NO WATER SITS IN THE BACKYARD FINAL SURVEY STATES THAT THE WATER WILL GET TRAPED BUT PASSING FINAL SURVEY AND FIELD INSPECTION ON HOMEOWNER WORD OF NO WATER SITTING. FYI HOMEOWNER HAS PUMP ON RIGHT SIDE OF THE HOUSE TO HELP WITH STRORMWATER SITTING IN FUTURE. ------------------------------------------------------------------------- meeting at 1pm | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/28/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE NEW FINAL SURVEY SHOWS THE DRAINAGE BEING TRAPED IN THE BACK AND NOT ALLOWING THE WATER TO FLOW TO THE ROADSIDE SWALES. ----------------------------------------------------------------------------------------- 7/10/2025 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STATES THAT THE DRAINAGE PATTERN IS TO FLAT CITY CODE STATES THAT THE DRAINAGE PATTERN MUST HAVE .10 OF FALL EVERY 20' PLEASE SEE CODE AT Section 300.01 D(4) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/10/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: THE FINAL SURVEY STATES THAT THE DRAINAGE PATTERN IS TO FLAT CITY CODE STATES THAT THE DRAINAGE PATTERN MUST HAVE .10 OF FALL EVERY 20' PLEASE SEE CODE AT Section 300.01 D(4) | |||
| ELECTRIC AND ALARM | 06/11/2025 | APPROVED | JSTEWART |
| Note: 6/6/2025 - PREVIOUS INSPECTION NOTES 1. Please have open wires not connected to equipment at Pump, encased in holding box with a secure cover. NEC 110.27 2. Please have open wires not connected to equipment at conduit in the (2) Corners of the pool deck encased in holding box with a secure cover. NEC 110.27 3. Enclosure is not Bonded. NEC 680.26(C) 4. Note: Hot tub is on seperate permit, But the open wiring laying on pool deck needs to be safed off with wing nuts and encased in a holding box with a secured cover or connect to Hot Tub . NEC 110.27 | |||
| ELECTRIC AND ALARM | 06/06/2025 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Please have open wires not connected to equipment at Pump, encased in holding box with a secure cover. NEC 110.27 2. Please have open wires not connected to equipment at conduit in the (2) Corners of the pool deck encased in holding box with a secure cover. NEC 110.27 3. Enclosure is not Bonded. NEC 680.26(C) 4. Note: Hot tub is on seperate permit, But the open wiring laying on pool deck needs to be safed off with wing nuts and encased in a holding box with a secured cover or connect to Hot Tub . NEC 110.27 | |||
| POOL DECK | 04/30/2025 | APPROVED | MCONTRYMAN |
| STEEL AND GROUND | 03/13/2025 | APPROVED | FWILLIS |
| Note: 3/12/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 3/12/2025 11:51:23 AM *** No steps are formed with rebar in shallow end per plan, R4501.18 Ladders and steps. | |||
| STEEL AND GROUND | 03/12/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 3/12/2025 11:51:23 AM *** No steps are formed with rebar in shallow end per plan, R4501.18 Ladders and steps. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/20/2025 | 02/26/2025 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM The top of the slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)H.Land Development Code Technical Manual, Section 300.01 (D)(6) (V-!7) The subject lot drainage must not negatively impact any adjacent property. Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. (J)J.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)) (V_16) General Notes. | |||
| ZON | COMPLETE | 02/20/2025 | 02/20/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BFLOOD | COMPLETE | 02/13/2025 | 02/20/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/13/2025 | 02/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/13/2025 | 02/20/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/13/2025 | 02/20/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/13/2025 | 02/14/2025 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | HOLD | 02/13/2025 | 02/13/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Equipment pad must be shown on site plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/30/2025 |
| SURCHARGE FS 533.721 | ¤2.38 | 03/03/2025 |
| SURCHARGE - FS 468.631 | ¤3.57 | 03/03/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 03/03/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/03/2025 |
| SITE PLAN 30 | ¤30.00 | 03/03/2025 |
| ADJUSTMENT 10% | (¤26.41) | 03/03/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/03/2025 |
| INSPECTION- POOL | ¤160.00 | 03/03/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤74.10 | 03/03/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤373.64 |