I want to search for...
Permit #2025020771
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-01180-0100 |
| Block: 01180 |
| Subdivision: 7034 - |
| Job Phone: 386-999-1042 |
| Location Address: 46 EDGE LN |
| Type: PO - POOL |
| Issue Date: 02/24/2025 |
| NOC: RECORDED |
| Applicant name: RYDER N BRAY |
| Owner: ZALDIVAR FERNANDO J & CARMEN L H&W |
|
Address 46 EDGE LN PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤103,000.00 |
| Job Description: POOL W/SCREEN ENCLOSURE |
| Type: CN |
Contractor
HAVEN POOLS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
25 PUTTER LANE PALM COAST, FL 32164 |
CPC1460243 (Exp: 08/31/2026) | 386-999-1042 |
Sub Contractors
JOSEPH DEREK CARTWRIGHT
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
151 RODEO ROAD ORMOND BEACH, FL 32174 |
SCC131150000 (Exp: 08/31/2026) | 386-310-7962 | (386)615-3713 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 04/30/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/30/2025 2:55:41 PM *** New inspection due to canceled inspection 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25: **** Missing one (of four anchors) on the back wall side as required by manufacturer and FBC R4501.7.2 / FBC-M1307.2 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 | |||
| POOL FINAL | 04/29/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 4/24/2025 - PREVIOUS INSPECTION NOTES 4/24/25: **** Missing one (of four anchors) on the back wall side as required by manufacturer and FBC R4501.7.2 / FBC-M1307.2 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 | |||
| POOL FINAL | 04/24/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/24/25: **** Missing one (of four anchors) on the back wall side as required by manufacturer and FBC R4501.7.2 / FBC-M1307.2 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25 1. Pool heater needs to be secured FBC R4501.7.2 / FBC-M1307.2 | |||
| POOL FINAL | 04/23/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 4/23/25 1. Pool heater needs to be secured FBC R4501.7.2 | |||
| U -UTILITY RESIDENTIAL FINAL | 04/21/2025 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/17/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 04/17/25 CORRECTIONS MADE _________________________________________________________________________________________________________________ 4/15/2025 - PREVIOUS INSPECTION NOTES ** 04/15/25 MUST DIG A SMALL SWALE AROUND THE PLANTER TO THE FENCE WITH AT LEAST 1" UNDER THE FENCE FOR DRAINAGE TO ESCAPE. ALSO THE ENTIRE FENCE LINE ALONG THE LEFT SIDE HOMEOWNER WILL REMOVE THE 1 COURSE OF SOD AND DIG DOWN TO BOTTOM OF FENCE TO ALLOW THE DRAIANGE TO ESCAPE ALONG THE FENCE LINE. __________________________________________________________________________________________________________________ 4/9/2025 - PREVIOUS INSPECTION NOTES 04/09/25 TPOLACEK*** MET WITH HOMEOWNER ON SITE. IN THE BACK LEFT CORNER THERE IS A SMALL PLANTER BED. I EXPLAINED WE WILL ALLOW THE PLANTER TO STAY HOWEVER, THEY MUST DIG A SMALL SWALE AROUND THE PLANTER TO THE FENCE WITH AT LEAST 1" UNDER THE FENCE FOR DRAINAGE TO ESCAPE. ALSO THE ENTIRE FENCE LINE ALONG THE LEFT SIDE HOMEOWNER WILL REMOVE THE 1 COURSE OF SOD AND DIG DOWN TO BOTTOM OF FENCE TO ALLOW THE DRAIANGE TO ESCAPE ALONG THE FENCE LINE. | |||
| ROW - FINAL INSPECTION | 04/17/2025 | APPROVED | EMADISON |
| Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/15/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 04/15/25 MUST DIG A SMALL SWALE AROUND THE PLANTER TO THE FENCE WITH AT LEAST 1" UNDER THE FENCE FOR DRAINAGE TO ESCAPE. ALSO THE ENTIRE FENCE LINE ALONG THE LEFT SIDE HOMEOWNER WILL REMOVE THE 1 COURSE OF SOD AND DIG DOWN TO BOTTOM OF FENCE TO ALLOW THE DRAIANGE TO ESCAPE ALONG THE FENCE LINE. __________________________________________________________________________________________________________________ 4/9/2025 - PREVIOUS INSPECTION NOTES 04/09/25 TPOLACEK*** MET WITH HOMEOWNER ON SITE. IN THE BACK LEFT CORNER THERE IS A SMALL PLANTER BED. I EXPLAINED WE WILL ALLOW THE PLANTER TO STAY HOWEVER, THEY MUST DIG A SMALL SWALE AROUND THE PLANTER TO THE FENCE WITH AT LEAST 1" UNDER THE FENCE FOR DRAINAGE TO ESCAPE. ALSO THE ENTIRE FENCE LINE ALONG THE LEFT SIDE HOMEOWNER WILL REMOVE THE 1 COURSE OF SOD AND DIG DOWN TO BOTTOM OF FENCE TO ALLOW THE DRAIANGE TO ESCAPE ALONG THE FENCE LINE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/09/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/09/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/09/25 TPOLACEK*** MET WITH HOMEOWNER ON SITE. IN THE BACK LEFT CORNER THERE IS A SMALL PLANTER BED. I EXPLAINED WE WILL ALLOW THE PLANTER TO STAY HOWEVER, THEY MUST DIG A SMALL SWALE AROUND THE PLANTER TO THE FENCE WITH AT LEAST 1" UNDER THE FENCE FOR DRAINAGE TO ESCAPE. ALSO THE ENTIRE FENCE LINE ALONG THE LEFT SIDE HOMEOWNER WILL REMOVE THE 1 COURSE OF SOD AND DIG DOWN TO BOTTOM OF FENCE TO ALLOW THE DRAIANGE TO ESCAPE ALONG THE FENCE LINE. | |||
| ELECTRIC AND ALARM | 03/31/2025 | APPROVED | MCONTRYMAN |
| Note: 3/27/2025 8:58:00 AM- PREVIOUS INSPECTION NOTES | |||
| ELECTRIC AND ALARM | 03/27/2025 | CANCELLED BY APPLICANT | NDIMATTINA |
| POOL DECK | 03/17/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/17/2025 2:27:28 PM *** | |||
| STEEL AND GROUND | 03/03/2025 | APPROVED | CVANSTRAHLEN |
Review History
| Department | Status | Date In | Date Out |
| BFLOOD | COMPLETE | 02/18/2025 | 02/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/18/2025 | 02/24/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/18/2025 | 02/24/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/18/2025 | 02/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/18/2025 | 02/18/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/18/2025 | 02/18/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/28/2025 |
| SURCHARGE FS 533.721 | ¤2.43 | 02/24/2025 |
| SURCHARGE - FS 468.631 | ¤3.65 | 02/24/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 02/24/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/24/2025 |
| SITE PLAN 30 | ¤30.00 | 02/24/2025 |
| ADJUSTMENT 10% | (¤27.03) | 02/24/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/24/2025 |
| INSPECTION- POOL | ¤160.00 | 02/24/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤80.34 | 02/24/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤379.39 |