I want to search for...
Permit #2025020877
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00100-0090 |
| CONDITIONED SPACE: 2063 sqft |
| OPENED PORCH (WITH ROOF) : 253 sqft |
| GARAGE: 424 sqft |
| Total Square Footage: 2740 sqft |
| Block: 00100 |
| Subdivision: - |
| Job Phone: 844-885-8913 |
| Location Address: 3 FIELDING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/11/2025 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES - FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤424,900.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Sub Contractors
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
CHRISTOPHER DENNIS O'CONNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 N LAKE CUNNINGHAM AVE JACKSONVILLE, FL 32257 |
ER13015361 (Exp: 08/31/2026) | 904-540-0858 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 04/02/2026 | APPROVED - AS NOTED | BVEIGA |
| Note: no/cc pvb/potable irrigation | |||
| U -UTILITY RESIDENTIAL FINAL | 04/02/2026 | FINAL APPROVED | BVEIGA |
| ROW - FINAL APRON (AFTER POUR) | 04/01/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/01/2026 | APPROVED | TPOLACEK |
| Note: 04-01-26 TPOLACEK*** INSPECTOR WENT ONSITRE AND SHOT CULVERT. CULVERT IS SET WITHIN THE SCOPE OF THE SWALE PLAN DIAGRAM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 3/30/2026 - PREVIOUS INSPECTION NOTES ** 03/30/26 CULVERT PIPE IS OUT OF TOLERANCE IN ACCORDANCE WITH THE ELEVATION SET BY THE CITY OF PALM COAST ON THE PROVIDED SWALE PLAN. IT EXCEEDS THE MINIMUM STANDARD. ** The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow ** (4) Proposed swale and culvert elevations must meet the minimum requirements of the swale plan. Section 300.01 C(4) V-16 Inspector Notes from Inspection 9270 3/12/26=AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR. IF IT RAINS, PLEASE BUILD THE DOUBLE THE CULVERT ELEVATIONS TO MAKE SURE IT IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 3/11/2026 - PREVIOUS INSPECTION NOTES ** 03/11/26/ CANCELLED BY PHIL VIA PHONE CALL NOT READY FOR INSPECTION ___________________________________________________________________________________________________ 3/4/2026 - PREVIOUS INSPECTION NOTES ** 03/04/26 CANCELLED VIA PHONE CALL FROM AJ LGI HOMES | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/01/2026 | CANCELLED BY INSPECTOR | TPOLACEK |
| Note: Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types | |||
| ROW - STORMWATER FINAL | 04/01/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/30/2026 | Disapproved - NO FEE | EMADISON |
| Note: ** 03/30/26 CULVERT PIPE IS OUT OF TOLERANCE IN ACCORDANCE WITH THE ELEVATION SET BY THE CITY OF PALM COAST ON THE PROVIDED SWALE PLAN. IT EXCEEDS THE MINIMUM STANDARD. ** The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow ** (4) Proposed swale and culvert elevations must meet the minimum requirements of the swale plan. Section 300.01 C(4) V-16 Inspector Notes from Inspection 9270 3/12/26=AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR. IF IT RAINS, PLEASE BUILD THE DOUBLE THE CULVERT ELEVATIONS TO MAKE SURE IT IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 3/11/2026 - PREVIOUS INSPECTION NOTES ** 03/11/26/ CANCELLED BY PHIL VIA PHONE CALL NOT READY FOR INSPECTION ___________________________________________________________________________________________________ 3/4/2026 - PREVIOUS INSPECTION NOTES ** 03/04/26 CANCELLED VIA PHONE CALL FROM AJ LGI HOMES | |||
| BLD - BUILDING FINAL | 03/30/2026 | FINAL APPROVED | MCONTRYMAN |
| Note: 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26 1. Dryer vent needs to be sealed in dryer box when not in use FBC-M1502.4.7 2. Notice to homeowner for AH in attic needs to be posted on panel box FBCR 403.3.6 3. AC chase needs to be sealed up FBC EC TABLE R402.4.1.1 | |||
| BLD - BUILDING FINAL | 03/26/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 3/26/26 1. Dryer vent needs to be sealed in dryer box when not in use FBC-M1502.4.7 2. Notice to homeowner for AH in attic needs to be posted on panel box FBCR 403.3.6 3. AC chase needs to be sealed up FBC EC TABLE R402.4.1.1 | |||
| ROW- PRE-APRON (PRE-POUR) | 03/12/2026 | APPROVED - AS NOTED | GBERTOLA |
| Note: 3/12/26=AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR. IF IT RAINS, PLEASE BUILD THE DOUBLE THE CULVERT ELEVATIONS TO MAKE SURE IT IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 3/11/2026 - PREVIOUS INSPECTION NOTES ** 03/11/26/ CANCELLED BY PHIL VIA PHONE CALL NOT READY FOR INSPECTION ___________________________________________________________________________________________________ 3/4/2026 - PREVIOUS INSPECTION NOTES ** 03/04/26 CANCELLED VIA PHONE CALL FROM AJ LGI HOMES | |||
| ROW- PRE-APRON (PRE-POUR) | 03/11/2026 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 03/11/26/ CANCELLED BY PHIL VIA PHONE CALL NOT READY FOR INSPECTION ___________________________________________________________________________________________________ 3/4/2026 - PREVIOUS INSPECTION NOTES ** 03/04/26 CANCELLED VIA PHONE CALL FROM AJ LGI HOMES | |||
| ELECTRIC - EARLY POWER | 03/09/2026 | APPROVED | RMARTIN |
| ROW- PRE-APRON (PRE-POUR) | 03/04/2026 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 03/04/26 CANCELLED VIA PHONE CALL FROM AJ LGI HOMES | |||
| INSULATION | 02/05/2026 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 02/03/2026 | APPROVED | HCAMACHO |
| Note: 2/2/2026 - PREVIOUS INSPECTION NOTES 1. Per manufacturer specs, all laps and seams must be sealed with approved tape | |||
| LATH/BRICK/ WATER BARRIER | 02/02/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Per manufacturer specs, all laps and seams must be sealed with approved tape | |||
| GRAVITY SEWER TEST | 02/02/2026 | APPROVED - AS NOTED | MKRASKI |
| Note: Via virtual inspection | |||
| SEWER TIE IN | 02/02/2026 | APPROVED | MKRASKI |
| ALL ROUGH | 01/30/2026 | APPROVED | HCAMACHO |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2467 Previous items have been looked at. Inspector Notes from Inspection 2460 1. Broken gusset plate on truss by front entry 2. Missing gable end bracing per plan at Garage | |||
| ALL ROUGH | 01/28/2026 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2467 Previous items have been looked at. Inspector Notes from Inspection 2460 1. Broken gusset plate on truss by front entry 2. Missing gable end bracing per plan at Garage | |||
| ELECTRIC-TUG | 01/21/2026 | APPROVED | HCAMACHO |
| ROOF VALLEY & METAL | 01/09/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: Previous items have been looked at. Inspector Notes from Inspection 2460 1. Broken gusset plate on truss by front entry 2. Missing gable end bracing per plan at Garage | |||
| WALL SHEATHING | 01/05/2026 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/05/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Broken gusset plate on truss by front entry 2. Missing gable end bracing per plan at Garage | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/23/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 12/12/2025 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 12/11/2025 | APPROVED | HCAMACHO |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/09/2025 | APPROVED | HCAMACHO |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/08/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 03/13/2025 | APPROVED | CBOWERMASTER |
| WILDLIFE CHECK - ENVIRONMENTAL | 02/25/2025 | APPROVED | DRODRIGUEZ |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 03/03/2026 | 03/03/2026 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC is cut off on top. Missing stamp. | |||
| SW1 | COMPLETE | 12/23/2025 | 12/23/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/23/2025 | 12/23/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/30/2025 | 09/30/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/29/2025 | 09/29/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/08/2025 | 04/08/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/03/2025 | 03/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/26/2025 | 02/28/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/26/2025 | 03/03/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM FL# 47271 is not synthetic underlayment and does not correspond to manufacturer listed. | |||
| SWALE | COMPLETE | 02/19/2025 | 03/10/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 02/19/2025 | 02/25/2025 |
| Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 02/25/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. | |||
| BADMIN | COMPLETE | 02/18/2025 | 02/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/18/2025 | 02/24/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Woorksheet 1. FL# 46442 not synthetic underlayment. Product Approval 1. FL# 13841-R6 not a sliding door. | |||
| CUSVC | COMPLETE | 02/18/2025 | 02/20/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/18/2025 | 02/24/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/18/2025 | 02/19/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/18/2025 | 02/21/2025 |
| LOCATE | COMPLETE | 02/18/2025 | 02/20/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/18/2025 | 02/21/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| SW1 | COMPLETE | 02/18/2025 | 02/19/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/18/2025 | 02/19/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/10/2026 |
| EXTENSION | ¤40.00 | 04/10/2026 |
| INSPECTION - RESIDENTIAL | ¤1,168.75 | 03/11/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤331.50 | 03/11/2025 |
| WATER- TURN ON | ¤25.00 | 03/11/2025 |
| ADJUSTMENT 10% | (¤153.03) | 03/11/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/11/2025 |
| CONNECTION FEES | ¤1,187.26 | 03/11/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 03/11/2025 |
| IMPACT FEE FIRE | ¤434.51 | 03/11/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/11/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/11/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 03/11/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/11/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 03/11/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/11/2025 |
| SURCHARGE FS 533.721 | ¤13.77 | 03/11/2025 |
| SURCHARGE - FS 468.631 | ¤20.66 | 03/11/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/11/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/11/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/11/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/11/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/11/2025 |
| SEWER INSPECTION | ¤25.00 | 03/11/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 03/11/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 03/11/2025 |
| SITE PLAN 30 | ¤30.00 | 03/11/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,774.59 |