I want to search for...

Permit #2025020898

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00320-0070
CONDITIONED SPACE: 2622 sqft
GARAGE: 998 sqft
PATIO/DECK (NO ROOF) : 316 sqft
OPENED PORCH (WITH ROOF) : 116 sqft
Total Square Footage: 4052 sqft
Block: 00320
Subdivision: -
Job Phone: 386-585-2654
Location Address: 13 FANSHAWE LN
Type: DU - DUPLEX
Issue Date: 02/27/2025
NOC: RECORDED
Applicant name: DESIDERIO CARLOS CARREIRO
Owner: CARLOS SOARES

Address

13 FANSHAW LANE

PALM COAST, FL 32137

Lot: 0070
Contracted Stated Job Value: ¤300,000.00
Job Description: Duplex
Type: CN

Contractor

RED LINE CONSTRUCTION CO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
FERNANDO M FARIA
Status Location Address State License Number Phone
ACTIVE

23 FREELAND LANE

PALM COAST, FL 32137

RF11067823 (Exp: 08/31/2027) 386-569-4336
DESIDERIO CARLOS CARREIRO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/19/2025 FINAL APPROVED MCONTRYMAN
U -UTILITY RESIDENTIAL FINAL 09/19/2025 FINAL APPROVED BWRIGHT
Note: 9/18/2025 - PREVIOUS INSPECTION NOTES 9/8/2025 - PREVIOUS INSPECTION NOTES Meter water pit are still to low. Please contact utility department clean out both meter pits so that ball valve handle is accessible/.clean off mud on the meter asseblies
ROW - FINAL INSPECTION 09/18/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 09/18/2025 Disapproved - NO FEE LFITZGERALD
Note: 9/8/2025 - PREVIOUS INSPECTION NOTES Meter water pit are still to low. Please contact utility department clean out both meter pits so that ball valve handle is accessible/.clean off mud on the meter asseblies
ROW - FINAL INSPECTION 09/08/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: ALL SEDIMENT THAT WASHED INTO RESERVE BEHIND LOT NEEDS TO HAVE SEED AND STRAW
U -UTILITY RESIDENTIAL FINAL 09/08/2025 Disapproved -FEE REQUIRED BWRIGHT
Note: Meter water pit are still to low. Please contact utility department.
BLD - BUILDING FINAL 09/08/2025 CANCELLED BY APPLICANT WEB
ROW - FINAL APRON (AFTER POUR) 09/04/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/04/2025 APPROVED - AS NOTED PFLANAGAN
Note: PER ENGINEERING LETTER WHY THE INSIDE SWALE ON THE LEFT SIDE PASSING AS NOTED THAT THE DRAINAGE IS WORKING AS INTENDED AND NO IMPACT ON ADJACENT LOTS -------------------------------------------------------------------------------------- 8/15/2025 - PREVIOUS INSPECTION NOTES ** 08/15/25 BUILDER PROPOSED A COMMON SWALE (DRAINAGE) ALONG BOTH THE RIGHT AND LEFT PROPERTY LINES YOU NOW SHOW AN INSIDE SWALE WITH A BERM ** SEE THE ATTACHED ** CONTRACTORS NEWS FLASHTHAT** WAS SENT TO ALL BUILDERS AND CONTRACTORS ** 15-108 (d) is the code; Excessive growth of grass, weeds, or brush and other overgrowth means grass or weeds or brush, bushes, shrubs, trees, vines, or flowering plants, and different live plant life that is allowed to grow in a wild and unkempt manner not in keeping with the neighborhood. CONTRACTORS NEWSFLASH Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/04/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/15/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 08/15/25 BUILDER PROPOSED A COMMON SWALE (DRAINAGE) ALONG BOTH THE RIGHT AND LEFT PROPERTY LINES YOU NOW SHOW AN INSIDE SWALE WITH A BERM ** SEE THE ATTACHED ** CONTRACTORS NEWS FLASHTHAT** WAS SENT TO ALL BUILDERS AND CONTRACTORS ** 15-108 (d) is the code; Excessive growth of grass, weeds, or brush and other overgrowth means grass or weeds or brush, bushes, shrubs, trees, vines, or flowering plants, and different live plant life that is allowed to grow in a wild and unkempt manner not in keeping with the neighborhood. CONTRACTORS NEWSFLASH Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns.
ELECTRIC - EARLY POWER 07/16/2025 APPROVED CVANSTRAHLEN
Note:
ELECTRIC - EARLY POWER 07/15/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix item before next inspection Side B electrical outlet box by electrical panel , need to have safe wires NEC 110.27-SAFE OFF ALL WIRING
ROW- PRE-APRON (PRE-POUR) 07/11/2025 APPROVED - AS NOTED PFLANAGAN
Note: CONTRACTOR ON SITE AND WE FIXED THE CULVERT ON THE LEFT AND HE STATES THAT HE WILL FIX THE FORMS TO HAVE 2" OF CONCRETE OVERT THE MITER ENDS IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. ------------------------------------------------------------------------------------ 7/10/2025 - PREVIOUS INSPECTION NOTES 1) LEFT CULVERT IS OUT OF THE TOLERANCE FROM THE ONE INVERT TO THE NEXT YOU ONLY ALLOWED .10 OF FLOW FROM ONE INVERT TO THE NEXT INVERT. THIS MEANS THAT THE CVULVERT IS PITCHED MORE THEN A .10. NEED TO RESET SO YOU ONLY HAVE .10 FROM EACH INVERT. PLEASE SEE SWALE PLAN DETAIL FOR INFO 2) CULVERT MITER ENDS NEED TO BE DUG OUT TO HAVE THE FOOTER MINIMUM OF 6"X6" FOR END OF THE CULVERTS. PLEASE SEE DRAWING #300.E FOR HELP. ------------------------------------------------------------------------------- 7/7/2025 - PREVIOUS INSPECTION NOTES CANCELED BY TEXT BY DC
ROW- PRE-APRON (PRE-POUR) 07/10/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) LEFT CULVERT IS OUT OF THE TOLERANCE FROM THE ONE INVERT TO THE NEXT YOU ONLY ALLOWED .10 OF FLOW FROM ONE INVERT TO THE NEXT INVERT. THIS MEANS THAT THE CVULVERT IS PITCHED MORE THEN A .10. NEED TO RESET SO YOU ONLY HAVE .10 FROM EACH INVERT. PLEASE SEE SWALE PLAN DETAIL FOR INFO 2) CULVERT MITER ENDS NEED TO BE DUG OUT TO HAVE THE FOOTER MINIMUM OF 6"X6" FOR END OF THE CULVERTS. PLEASE SEE DRAWING #300.E FOR HELP. ------------------------------------------------------------------------------- 7/7/2025 - PREVIOUS INSPECTION NOTES CANCELED BY TEXT BY DC
FIREWALL FINAL 07/09/2025 CANCELLED BY APPLICANT WEB
FIREWALL FINAL 07/09/2025 APPROVED HCAMACHO
WINDOW NAILING 07/09/2025 CANCELLED BY APPLICANT WEB
Note: This inspection is for the missing House to Garage doors installation.
WINDOW NAILING 07/09/2025 APPROVED HCAMACHO
ROW- PRE-APRON (PRE-POUR) 07/07/2025 CANCELLED BY APPLICANT PFLANAGAN
Note: CANCELED BY TEXT BY DC
ROW- PROJECT STATUS 07/01/2025 APPROVED GBERTOLA
Note: 7/1/25=THE LEFT CORNER FACING THE HOUSE NEEDS TO HAVE A 4/1 SLOPE, AS IT WAS AROUND A 3/1 SLOPE DURING THE INSPECTION
U-CROSS CONNECTION 06/18/2025 APPROVED DHANEY
GRAVITY SEWER TEST 06/18/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 FBC 3303.5 SWALE BLOCKED
SEWER TIE IN 06/18/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 FBC 3303.5 SWALE BLOCKED
LATH/BRICK/ WATER BARRIER 05/19/2025 APPROVED JSTEWART
FIREWALL DRYWALL NAILING 05/19/2025 CANCELLED BY APPLICANT WEB
Note: 5/13/2025 - PREVIOUS INSPECTION NOTES 1. This is for draft stop only. Note- Call back Drywall Nailing after sheetrock is installed, before mud is applied.
FIREWALL DRYWALL NAILING 05/19/2025 APPROVED JSTEWART
Note: New inspection due to canceled inspection 5/13/2025 - PREVIOUS INSPECTION NOTES 1. This is for draft stop only. Note- Call back Drywall Nailing after sheetrock is installed, before mud is applied.
INSULATION 05/13/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. R value for block wall on the Energy Calcs calls for R6. The house has R5.1 installed. Please revise Energy calcs for Final Inspection and make sure A/C equipment matches what is going to be installed.
FIREWALL DRYWALL NAILING 05/13/2025 PARTIALLY APPROVED HCAMACHO
Note: 1. This is for draft stop only. Note- Call back Drywall Nailing after sheetrock is installed, before mud is applied.
FIREWALL DRYWALL NAILING 05/09/2025 Disapproved - NO FEE HCAMACHO
Note: Need draft stop over front porch. Make sure that whole area is all blocked, there's a weird roof over this area. See Plans.
ALL ROUGH 05/09/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Need fireblocking on extra framed wall in living room for fireplace, both sides. Marked in Orange 2. Need Product approval # for slidding glass doors. It is not listed on the product approval sheet. Needs rivision. *Note- Energy Calcs show R6 on block walls, what is installed is R5. Need to revise energy calcs before insualtion inspection, or else we can't pass the insulation inspection*.
WALL SHEATHING 05/01/2025 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/29/2025 APPROVED HCAMACHO
ROOF VALLEY & METAL 04/29/2025 APPROVED HCAMACHO
FIREWALL FRAMING 04/29/2025 APPROVED HCAMACHO
TIE BEAM / LINTEL 04/15/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Clear swale of concrete. Needs to be done by next inspection. FBC 3303.5 SWALE CLEAR 2. Contain Garbage. FBC 3302.2 NEEDS DUMPSTER
FOUND SURVEY APPROVED (OFFICE) 04/14/2025 APPROVED RRICKS
MONOLITHIC SLAB 04/03/2025 APPROVED HCAMACHO
MONOLITHIC SLAB 04/02/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Missing #5 rebar at garage wall, both sides. See detail 6/F on plans. *Marked*
PLUMBING 1ST ROUGH UNDERGROUND 03/31/2025 APPROVED - AS NOTED MGIBSON
Note: FBC 3303.5 SWALE BLOCKED
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/27/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 03/13/2025 APPROVED CBOWERMASTER
WILDLIFE CHECK - ENVIRONMENTAL 02/25/2025 APPROVED DRODRIGUEZ

Review History

Department Status Date In Date Out
MECH COMPLETE 09/16/2025 09/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 09/11/2025 09/12/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition. Do not need state card on revision
SW1 COMPLETE 08/25/2025 08/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Enginner letter accpeted.
ENGIN1 COMPLETE 04/14/2025 04/14/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/14/2025 04/14/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
PLFM COMPLETE 04/14/2025 04/15/2025
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 2/26/25, the structure will not fall inside the SFHA. No elevation certificates are required.
BLD COMPLETE 03/26/2025 03/27/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 02/26/2025 02/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/26/2025 02/27/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 02/26/2025 02/26/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/26/2025 02/26/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLENV COMPLETE 02/20/2025 02/25/2025
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 02/25/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
SWALE COMPLETE 02/19/2025 02/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 02/18/2025 02/24/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 02/18/2025 02/24/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Worksheet 1. FL# 10124-R25 out of cycle. We are in the 2023 code cycle. 2. FL# 10626-R23 out of cycle. Product Approval 1. Please list address on product approval form. 2. FL# 13265.1-R1 out of cycle.
CUSVC COMPLETE 02/18/2025 02/19/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 02/18/2025 02/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/18/2025 02/19/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/18/2025 02/21/2025
LOCATE COMPLETE 02/18/2025 02/25/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 02/18/2025 02/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/18/2025 02/19/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/18/2025 02/20/2025
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/20/2025
SW ENG REINSPECTION 20 ¤20.00 09/20/2025
SW ENG REINSPECTION 30 ¤30.00 09/20/2025
SW ENG - REVIEW 20 ¤20.00 02/27/2025
SW ENG RES REVIEW 200 ¤200.00 02/27/2025
SEWER CREDIT (¤1,147.00) 02/27/2025
SEWER INSPECTION ¤25.00 02/27/2025
SEWER CAPITAL FACILITY ¤12,241.04 02/27/2025
WATER CAPITAL FACILITY FEE ¤8,702.28 02/27/2025
SITE PLAN 30 ¤30.00 02/27/2025
CONNECTION FEES ¤2,374.52 02/27/2025
FC IMPACT FEE EMS ¤124.00 02/27/2025
IMPACT FEE FIRE ¤869.02 02/27/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/27/2025
FC IMPACT FEE LIBRARY ¤536.00 02/27/2025
IMPACT FEE PARKS ¤3,656.02 02/27/2025
IMPACT FEE SCHOOL ¤10,900.00 02/27/2025
IMPACT FEE TRANSPORTATION ¤2,974.00 02/27/2025
WATER -IRRIGATION INSPECTION ¤50.00 02/27/2025
SURCHARGE FS 533.721 ¤17.17 02/27/2025
SURCHARGE - FS 468.631 ¤25.76 02/27/2025
SW ENG - FOUNDATION SURVEY ¤20.00 02/27/2025
SW ENG INSPECTION 80 ¤80.00 02/27/2025
SW ENG PRE APRON ¤30.00 02/27/2025
WATER- TURN ON ¤50.00 02/27/2025
ADJUSTMENT 10% (¤190.80) 02/27/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/27/2025
INSPECTION - RESIDENTIAL ¤1,463.00 02/27/2025
PLAN REVIEW - RESIDENTIAL ¤414.96 02/27/2025
Fees Total Due: ¤0.00 Total Paid: ¤44,013.47