I want to search for...
Permit #2025020911
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00450-0230 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00450 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 68 PIEDMONT DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/25/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE PORT SAINT LUCIE, FL 34986 |
|
Address 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/06/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/6/2025 1:31:28 PM *** 6/6/25: 1). Guest bathroom tub spout needs to be flush with the wall and re-sealed to create a water tight seal as required. FBC-P2705.1(3) 2). Guest bathroom: left side vanity drain leaks. FBC-P2503.5.2 3). Safety eye in garage needs plastic cover removed. FBC [A]107.4 6/5/2025 - PREVIOUS INSPECTION NOTES 6/5/25: Cancelled by Applicant in person at @ 10:40. (Roof and smokes checked). | |||
| BLD - BUILDING FINAL | 06/06/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/6/2025 3:20:29 PM *** 6/6/25: Repairs verified via FaceTime video/audio phone app at @ 15:13. 6/6/2025 - PREVIOUS INSPECTION NOTES 6/6/25: 1). Guest bathroom tub spout needs to be flush with the wall and re-sealed to create a water tight seal as required. FBC-P2705.1(3) 2). Guest bathroom: left side vanity drain leaks. FBC-P2503.5.2 3). Safety eye in garage needs plastic cover removed. FBC [A]107.4 6/5/2025 - PREVIOUS INSPECTION NOTES 6/5/25: Cancelled by Applicant in person at @ 10:40. (Roof and smokes checked). | |||
| ROW - STORMWATER FINAL | 06/06/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++ 6/2/2025 - PREVIOUS INSPECTION NOTES 06/02/25 TPOLACEK*** THERE IS TRASH AND CONSTRUCTION DEBRIS ALONG VACANT TO THE RIGHT FRONT TO BACK. PLEASE REMOVE. THEREIS A SMALL OVER POUR OF CONCRETE IN SWALE ALONG RIGHT SIDE VACANT THAT MUST BE REMOVED ASAP. IN THE BACK LEFT CORNER OF PROPERTY THERE IS A SMALL AREA THAT NEEDS A FEW PIECES OF SOD. SEED AND STRAW IS NOT PERMITTED ALONG DITCHES OR CANALS. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ROW FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | 06/06/2025 | FINAL APPROVED | LFITZGERALD |
| Note: 6/2/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 no irr-no cc no wires run from tank to panel-utility informed | |||
| BLD - BUILDING FINAL | 06/05/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/5/2025 10:43:02 AM *** 6/5/25: Cancelled by Applicant in person at @ 10:40. (Roof and smokes checked). | |||
| U -UTILITY RESIDENTIAL FINAL | 06/02/2025 | Disapproved - NO FEE | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 no irr-no cc no wires run from tank to panel-utility informed | |||
| ROW - FINAL APRON (AFTER POUR) | 06/02/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/02/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 06/02/25 TPOLACEK*** THERE IS TRASH AND CONSTRUCTION DEBRIS ALONG VACANT TO THE RIGHT FRONT TO BACK. PLEASE REMOVE. THEREIS A SMALL OVER POUR OF CONCRETE IN SWALE ALONG RIGHT SIDE VACANT THAT MUST BE REMOVED ASAP. IN THE BACK LEFT CORNER OF PROPERTY THERE IS A SMALL AREA THAT NEEDS A FEW PIECES OF SOD. SEED AND STRAW IS NOT PERMITTED ALONG DITCHES OR CANALS. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ROW FINAL | |||
| ELECTRIC - EARLY POWER | 05/30/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/30/2025 1:14:43 PM *** 5/30/25: FPL emailed to release power. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/29/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/29/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U-CROSS CONNECTION | 05/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| ROW- PRE-APRON (PRE-POUR) | 05/14/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 05/14/25 TPOLACEK**** ON THE RIGHT SIDE OF THE MITERED END THERE IS AN AT&T BOX WITHIN 6" INSPECTOR WILL EMAIL ATT TO HAVE BOX MOVED. SEE PHOTO AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| GRAVITY SEWER TEST | 05/14/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 05/14/2025 | APPROVED | MGIBSON |
| INSULATION | 05/08/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/8/2025 12:44:21 PM *** 5/6/2025 - PREVIOUS INSPECTION NOTES 5/6/25: 1). Previously listed item 1 remains unresolved. 1). 5ft head pressure not holding. FBC-P2503.5.1 -->> Please fill to the top of the pipe to assure that it holds. 2). Firestop at top plate above breaker panel is incomplete. FBC-R302.11 3). Firestop at top plate penetration for dryer exhaust is incomplete. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/2/2025 12:13:59 PM *** 5/2/25: Check at Insulation Inspection. 1). 5ft head pressure not holding. FBC-P2503.5.1 | |||
| INSULATION | 05/06/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/6/2025 12:22:27 PM *** 5/6/25: 1). Previously listed item 1 remains unresolved. 1). 5ft head pressure not holding. FBC-P2503.5.1 -->> Please fill to the top of the pipe to assure that it holds. 2). Firestop at top plate above breaker panel is incomplete. FBC-R302.11 3). Firestop at top plate penetration for dryer exhaust is incomplete. FBC-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/2/2025 12:13:59 PM *** 5/2/25: Check at Insulation Inspection. 1). 5ft head pressure not holding. FBC-P2503.5.1 | |||
| PEP TANK INSTALLATION REQUEST | 05/06/2025 | APPROVED | CBOWERMASTER |
| ALL ROUGH | 05/02/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/2/2025 12:13:59 PM *** 5/2/25: Check at Insulation Inspection. 1). 5ft head pressure not holding. FBC-P2503.5.1 | |||
| LATH/BRICK/ WATER BARRIER | 05/01/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/1/2025 2:01:31 PM *** | |||
| ROOF VALLEY & METAL | 04/25/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/25/2025 2:34:50 PM *** Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 4/23/2025 11:37:19 AM *** 4/23/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Missing overvalley tie downs at all (3) 'V' trusses (left side). Highlighted on truss plan. FBC [A]107.4 2). Missing insulating plates at both garage HJ7 trusses and at front left HJ3 truss. (cannot see from either side or from below). FBC [A]107.4 3). Please repair Silt Fence on left side. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 4/15/2025 1:32:25 PM *** 4/15/25: 1). Silt fence on both left and right sides needs to be completed and installed fence needs repair. FBC 3307.1 | |||
| WALL SHEATHING | 04/23/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2025 11:11:32 AM *** Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 4/15/2025 1:32:25 PM *** 4/15/25: 1). Silt fence on both left and right sides needs to be completed and installed fence needs repair. FBC 3307.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/23/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2025 11:37:19 AM *** 4/23/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Missing overvalley tie downs at all (3) 'V' trusses (left side). Highlighted on truss plan. FBC [A]107.4 2). Missing insulating plates at both garage HJ7 trusses and at front left HJ3 truss. (cannot see from either side or from below). FBC [A]107.4 3). Please repair Silt Fence on left side. FBC 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 4/15/2025 1:32:25 PM *** 4/15/25: 1). Silt fence on both left and right sides needs to be completed and installed fence needs repair. FBC 3307.1 | |||
| TIE BEAM / LINTEL | 04/15/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/15/2025 1:32:25 PM *** 4/15/25: 1). Silt fence on both left and right sides needs to be completed and installed fence needs repair. FBC 3307.1 | |||
| MONOLITHIC SLAB | 04/03/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/3/2025 1:12:09 PM *** | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/01/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/31/2025 | APPROVED | MGIBSON |
| Note: 3/28/2025 - PREVIOUS INSPECTION NOTES | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/28/2025 | CANCELLED BY APPLICANT | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 03/26/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 03/14/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/16/2025 | 04/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/01/2025 | 04/01/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/01/2025 | 04/01/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/26/2025 | 03/26/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/19/2025 | 02/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/19/2025 | 02/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/19/2025 | 02/19/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/19/2025 | 02/25/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/19/2025 | 02/19/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/19/2025 | 02/24/2025 |
| LOCATE | COMPLETE | 02/19/2025 | 02/20/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/19/2025 | 02/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/19/2025 | 02/19/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/19/2025 | 02/20/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/19/2025 | 02/27/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | 02/25/2025 |
| ADJUSTMENT 10% | (¤120.20) | 02/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/25/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 02/25/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 02/25/2025 |
| CONNECTION FEES | ¤1,187.26 | 02/25/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 02/25/2025 |
| IMPACT FEE FIRE | ¤434.51 | 02/25/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/25/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/25/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 02/25/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 02/25/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 02/25/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/25/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 02/25/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 02/25/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/25/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/25/2025 |
| SW ENG PRE APRON | ¤30.00 | 02/25/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/25/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/25/2025 |
| SEWER CREDIT | (¤1,147.00) | 02/25/2025 |
| SEWER INSPECTION | ¤25.00 | 02/25/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 02/25/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 02/25/2025 |
| SITE PLAN 30 | ¤30.00 | 02/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,252.25 |