I want to search for...
Permit #2025020922
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00190-0090 |
| Block: 00190 |
| Subdivision: 7025 - |
| Job Phone: 904-461-0070 |
| Location Address: 1 PERTHSHIRE LN |
| Type: ME - MECHANICAL |
| Issue Date: 02/20/2025 |
| NOC: Unknown |
| Applicant name: STEPHEN R CHAPMAN |
| Owner: CARLSON CHARLENE MARY LIFE ESTATE |
|
Address 1 PERTHSHIRE LANE PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤11,259.44 |
| Job Description: hvac like for like |
| Type: CN |
Contractor
ALL AMERICAN AIR CONDITIONING & HEATING CONTRACTOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1010 SR 312 St. Augustine, FL 32090 |
CAC057680 (Exp: 08/31/2026) | 904-461-0070 | 904-471-7543 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 08/14/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/14/2025 12:25:46 PM *** 5/7/2025 - PREVIOUS INSPECTION NOTES 5/7/25: 1). Hole in ceiling at MC cable feed into disconnect needs to be sealed with approved material. FBC-R302.11(4) 2). Hole in ceiling at old and new all-thread holes need to be sealed with approved material. FBC-R302.11(4) 3). 1 of 3 locking port caps are not locked. FBC-M1411.8 4). Breaker for AHU is too small. (Min.-51amp / Max.-60amp -- 50amp installed) 5). No permit, AHRI or other documents on site as required. FBC [A]107.3.1 | |||
| HVAC FINAL | 05/07/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/7/2025 4:04:59 PM *** 5/7/25: 1). Hole in ceiling at MC cable feed into disconnect needs to be sealed with approved material. FBC-R302.11(4) 2). Hole in ceiling at old and new all-thread holes need to be sealed with approved material. FBC-R302.11(4) 3). 1 of 3 locking port caps are not locked. FBC-M1411.8 4). Breaker for AHU is too small. (Min.-51amp / Max.-60amp -- 50amp installed) 5). No permit, AHRI or other documents on site as required. FBC [A]107.3.1 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/05/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/20/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/20/2025 |
| ADJUSTMENT 10% | (¤9.00) | 02/20/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/20/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 02/20/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |