I want to search for...

Permit #2025020958

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7007-00400-0360
Block: 00400
Subdivision: -
Job Phone: 386-931-0184
Location Address: 56 FURNESS PL
Type: PO - POOL
Issue Date: 03/26/2025
NOC: RECORDED
Applicant name: ROY CHARLES WALDHAUER II
Owner: SOUSA ISABELLA

Address

24 PAHQUIOQUE AVE APT 3

DANBURY, CT 06810

Lot: 0360
Contracted Stated Job Value: ¤88,000.00
Job Description: Enclosed Swimming Pool
Type: CN

Contractor

WALDHAUER & SON INC
Status Location Address State License Number Phone
ACTIVE

1600 N STATE STREET # 102

BUNNELL, FL 32110

CPC057029 (Exp: 08/31/2026) 386-263-8272

Sub Contractors

CHRISTOPHER I HALL
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 2413

Bunnell, FL 32110

EC13002161 (Exp: 08/31/2028) (386) 437-2966 386-437-5042
ROY CHARLES WALDHAUER
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

, 0

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289

Inspection History

Type Request Date Result Inspector
POOL FINAL 02/06/2026 FINAL APPROVED HCAMACHO
U -UTILITY RESIDENTIAL FINAL 01/14/2026 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/13/2026 APPROVED TPOLACEK
Note: 1/8/2026 - PREVIOUS INSPECTION NOTES 01-08-26 TPOLACEK*** FINAL SURVEY MUST INDICATE FFE OF POOL DECK, THERE SHOULD BE A MARKER INDICATING WHERE EACH SHOT WAS TAKEN NEXT TO THE ELEVATION (IE. AN X OR A /) SURVEY MUST CAPTURE ALL DRAINAGE CONVEYANCES AND SHOW POSITIVE FALL. DRAINAGE MAY NOT NEG IMPACT ADJOINING PROPERTIES OR SUBJECT PROPERTY. "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17"
ROW FIELD SURVEY /GRADING CERTIFICATION 01/13/2026 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 01/13/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/08/2026 Disapproved - NO FEE TPOLACEK
Note: 01-08-26 TPOLACEK*** FINAL SURVEY MUST INDICATE FFE OF POOL DECK, THERE SHOULD BE A MARKER INDICATING WHERE EACH SHOT WAS TAKEN NEXT TO THE ELEVATION (IE. AN X OR A /) SURVEY MUST CAPTURE ALL DRAINAGE CONVEYANCES AND SHOW POSITIVE FALL. DRAINAGE MAY NOT NEG IMPACT ADJOINING PROPERTIES OR SUBJECT PROPERTY. "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17"
ELECTRIC AND ALARM 11/19/2025 APPROVED HCAMACHO
POOL DECK 06/17/2025 APPROVED HCAMACHO
POOL DECK 06/16/2025 Disapproved - NO FEE JSTEWART
Note: Please remove Rebar from pool shell wall, bent over to Pool deck, Does not meet Clearance from soil, and concrete coverage. Min 3" from soil at ground and 2" clearence from the top of the slab coverage. FBC R404.1.3.3.7.4
STEEL AND GROUND 04/01/2025 APPROVED HCAMACHO

Review History

Department Status Date In Date Out
BFLOOD COMPLETE 02/19/2025 02/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 02/19/2025 02/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 02/19/2025 02/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 02/19/2025 02/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/19/2025 02/26/2025
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM The top of the slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)H.Land Development Code Technical Manual, Section 300.01 (D)(6) (V-!7) The subject lot drainage must not negatively impact any adjacent property. Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. (J)J.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)) (V_16)
ZON COMPLETE 02/19/2025 02/20/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤25.86) 03/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/26/2025
INSPECTION- POOL ¤160.00 03/26/2025
PLAN REVIEW - RESIDENTIAL ¤68.64 03/26/2025
SURCHARGE FS 533.721 ¤2.33 03/26/2025
SURCHARGE - FS 468.631 ¤3.49 03/26/2025
SW ENG INSPECTION 40 ¤40.00 03/26/2025
SW ENG - REVIEW 20 ¤20.00 03/26/2025
SITE PLAN 30 ¤30.00 03/26/2025
Fees Total Due: ¤0.00 Total Paid: ¤328.60