I want to search for...
Permit #2025021121
Permit Details
Status: COED
| Parcel Id: 07-11-31-7064-00370-0150 |
| CONDITIONED SPACE: 1546 sqft |
| GARAGE: 408 sqft |
| OPENED PORCH (WITH ROOF) : 42 sqft |
| Total Square Footage: 1996 sqft |
| Block: 00370 |
| Subdivision: - |
| Job Phone: 904-268-7730 |
| Location Address: 8 LLEBERRY PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/14/2025 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
ADAM JASON OCONNOR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13013779 (Exp: 08/31/2026) | 407-321-0064 X3432 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1165 SOUTH 5TH MACCLENNY, FL 32063 |
CCC1330709 (Exp: 08/31/2026) | 904-322-9409 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 04/17/2026 | FINAL APPROVED | TPOLACEK |
| Note: Inspector Notes from Inspection 9035 NO CC / NO IRR | |||
| ROW - FINAL APRON (AFTER POUR) | 04/16/2026 | APPROVED | FSLADISH |
| Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/16/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/16/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/10/2026 - PREVIOUS INSPECTION NOTES 4/10/26 YOUR ELEVATIONS IN THE MIDDLE REAR (24.97) SHOW DRAINAGE WILL POOL HERE AND NOT HAVE POSITIVE FORWARD DRAINAGE FLOW. SEE PHOTO FOR REFERENCE | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/16/2026 | CANCELLED BY INSPECTOR | FSLADISH |
| Note: Inspector Notes from Inspection 9463 4/16/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 4/10/2026 - PREVIOUS INSPECTION NOTES 4/10/26 YOUR ELEVATIONS IN THE MIDDLE REAR (24.97) SHOW DRAINAGE WILL POOL HERE AND NOT HAVE POSITIVE FORWARD DRAINAGE FLOW. SEE PHOTO FOR REFERENCE 4/16/26 Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. | |||
| ROW - STORMWATER FINAL | 04/16/2026 | APPROVED | FSLADISH |
| Note: 4/16/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| BLD - BUILDING FINAL | 04/16/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/16/2026 1:42:42 PM *** Final Approved 4/10/2026 - PREVIOUS INSPECTION NOTES 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: 1). Open space in breaker panel requires the manufacturer approved blank. blank that is installed does not cover the opening. NEC 408.7 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). Ground pipe raceway at Main panel needs to be secured. NEC-334.30 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). 8). 1 of three locking caps is not locked. FBCR M1411.8 3/11/26 From Early Power Inspection NOTE: Corrections required prior to Building Final Inspection. 1). Surge protecter and TUG outlet breaker spots will need top be switched so that the surge protector is in the first spot on the buss bar below the main breaker as required. NEC-230.67(A)/(B) 2). Kitchen island wall outlet below counter cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)] | |||
| U-CROSS CONNECTION | 04/16/2026 | APPROVED - AS NOTED | TLOWE |
| Note: NO CC / NO IRR | |||
| BLD - BUILDING FINAL | 04/10/2026 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26: 1). Open space in breaker panel requires the manufacturer approved blank. blank that is installed does not cover the opening. NEC 408.7 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). Ground pipe raceway at Main panel needs to be secured. NEC-334.30 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). 8). 1 of three locking caps is not locked. FBCR M1411.8 3/11/26 From Early Power Inspection NOTE: Corrections required prior to Building Final Inspection. 1). Surge protecter and TUG outlet breaker spots will need top be switched so that the surge protector is in the first spot on the buss bar below the main breaker as required. NEC-230.67(A)/(B) 2). Kitchen island wall outlet below counter cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)] | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/10/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 4/10/26 YOUR ELEVATIONS IN THE MIDDLE REAR (24.97) SHOW DRAINAGE WILL POOL HERE AND NOT HAVE POSITIVE FORWARD DRAINAGE FLOW. SEE PHOTO FOR REFERENCE | |||
| BLD - BUILDING FINAL | 04/08/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/8/2026 12:49:35 PM *** 4/8/26: 1). Open space in breaker panel requires the manufacturer approved blank. blank that is installed does not cover the opening. NEC 408.7 2) HVAC: Model numbers for Installed units do not match energy calcs. FBC [A] 107.4 3). Ground pipe raceway at Main panel needs to be secured. NEC-334.30 4). Dryer exhaust gooseneck needs screen removed. FBC M1502.3 5). Interior dryer exhaust is not capped, plugged or taped off as required. FBC-M1502.4.7 6). UL 325.6 / 16CFR part 1211 - Garage door opener safety eyes - Maximum OC height of 6" (minimum 2" off finished floor) 7). drywall screws must be removed from attic access framing so that drywall panel sits flush with ceiling. FBC-R302.11(4). 8). 1 of three locking caps is not locked. FBCR M1411.8 3/11/26 From Early Power Inspection NOTE: Corrections required prior to Building Final Inspection. 1). Surge protecter and TUG outlet breaker spots will need top be switched so that the surge protector is in the first spot on the buss bar below the main breaker as required. NEC-230.67(A)/(B) 2). Kitchen island wall outlet below counter cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)] | |||
| ROW- PRE-APRON (PRE-POUR) | 03/19/2026 | APPROVED | FSLADISH |
| Note: 3/19/26 MINIMUM REQUIREMENTS MET AT TIME OF INSPECTION. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR 3/18/2026 - PREVIOUS INSPECTION NOTES 1) THERE ARE LOT OF AREAS THAT DON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE NEED TO HAVE 4" ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY. 2) NOTE THIS CULVERT IS HIGHER THEN NUMBER 6 LLEBERRY PATH PLEASE FIX SO WATER WILL FLOW CORRECTLY SINCE THESE ARE YOUR PROJECTS. ------------------------------------------------------------------------------ 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY _________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/18/2026 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THERE ARE LOT OF AREAS THAT DON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE NEED TO HAVE 4" ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY. 2) NOTE THIS CULVERT IS HIGHER THEN NUMBER 6 LLEBERRY PATH PLEASE FIX SO WATER WILL FLOW CORRECTLY SINCE THESE ARE YOUR PROJECTS. ------------------------------------------------------------------------------ 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY _________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/17/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/17/26 RECEIVED A TEXT FROM DOYLE CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY _________________________________________________________________________________________________________________________________ 3/16/2026 - PREVIOUS INSPECTION NOTES 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/16/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/16/26 RECEIVED A TEXT FROM JAMES CM WHO REQUESTED TO PLEASE CANCEL THIS PREPOUR INSPECTION FOR TODAY. | |||
| ELECTRIC - EARLY POWER | 03/11/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/11/2026 1:02:05 PM *** 3/11/26: FPL emailed to release power. NOTE: Corrections required prior to Building Final Inspection. 1). Surge protecter and TUG outlet breaker spots will need top be switched so that the surge protector is in the first spot on the buss bar below the main breaker as required. NEC-230.67(A)/(B) 2). Kitchen island wall outlet below counter cannot be located where it is since the counter overhang exceeds 6" past the support base. [NEC-210.52(C)(3)(3)] 3/10/2026 - PREVIOUS INSPECTION NOTES 3/10/26: NOT READY AT ALL. SCHEDULED TOO EARLY. NO CALL TO CANCEL NOTE: Electricians have not started safing off electric as required for Early Power. NEC-110.27 3/9/2026 - PREVIOUS INSPECTION NOTES 3/9/26: Cancelled by Applicant via text at @ 0839. Inspector Notes from Inspection 2200 1/16/26 Email sent to FPL | |||
| ELECTRIC - EARLY POWER | 03/10/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/10/2026 10:16:41 AM *** 3/10/26: NOT READY AT ALL. SCHEDULED TOO EARLY. NO CALL TO CANCEL NOTE: Electricians have not started safing off electric as required for Early Power. NEC-110.27 3/9/2026 - PREVIOUS INSPECTION NOTES 3/9/26: Cancelled by Applicant via text at @ 0839. Inspector Notes from Inspection 2200 1/16/26 Email sent to FPL | |||
| ELECTRIC - EARLY POWER | 03/09/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: 3/9/26: Cancelled by Applicant via text at @ 0839. Inspector Notes from Inspection 2200 1/16/26 Email sent to FPL | |||
| SEWER TIE IN | 03/05/2026 | APPROVED | KSANDOE |
| PEP TANK INSTALLATION REQUEST | 02/19/2026 | APPROVED | ISANDERSON |
| Note: 2/18/2026 8:40:09 AM- PREVIOUS INSPECTION NOTES Siding is not complete. | |||
| PEP TANK INSTALLATION REQUEST | 02/17/2026 | Disapproved - NO FEE | ISANDERSON |
| Note: Siding is not complete. | |||
| LATH/BRICK/ WATER BARRIER | 02/13/2026 | APPROVED | BTAYLOR |
| Note: New inspection due to canceled inspection 1/30/2026 - PREVIOUS INSPECTION NOTES 1. Can not approve untill after windows and exterior doors have been installed | |||
| WINDOW NAILING | 02/13/2026 | APPROVED | BTAYLOR |
| Note: 2/12/2026 - PREVIOUS INSPECTION NOTES 2-12-26 1. Missing window in kitchen. | |||
| LATH/BRICK/ WATER BARRIER | 02/12/2026 | CANCELLED BY APPLICANT | WEB |
| Note: 1/30/2026 - PREVIOUS INSPECTION NOTES 1. Can not approve untill after windows and exterior doors have been installed | |||
| WINDOW NAILING | 02/12/2026 | Disapproved - NO FEE | BTAYLOR |
| Note: 2-12-26 1. Missing window in kitchen. | |||
| INSULATION | 02/05/2026 | APPROVED | CVANSTRAHLEN |
| Note: PLEASE FASTENED THE PLASTIC ON WINDOWS AND DOORS Inspector Notes from Inspection 2420 2/2/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection before next inspection Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 2026 - PREVIOUS INSPECTION NOTES 1/30/26 2. Dryer duct seams (at change of direction) must be sealed 5. No windows or SGD installed 6. Kitchen sink drain requires N/P at bottom plate | |||
| ALL ROUGH | 02/03/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: 2/2/2026 - PREVIOUS INSPECTION NOTES Please fix items from previous inspection before next inspection Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 2026 - PREVIOUS INSPECTION NOTES 1/30/26 2. Dryer duct seams (at change of direction) must be sealed 5. No windows or SGD installed 6. Kitchen sink drain requires N/P at bottom plate | |||
| ALL ROUGH | 02/02/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items from previous inspection before next inspection Please secured and fastned plastic covering windows , windows nailing isnpection will be add to this permit after insulation inspection if windows are not in place building must be dry-in 2026 - PREVIOUS INSPECTION NOTES 1/30/26 2. Dryer duct seams (at change of direction) must be sealed 5. No windows or SGD installed 6. Kitchen sink drain requires N/P at bottom plate | |||
| LATH/BRICK/ WATER BARRIER | 01/30/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Can not approve untill after windows and exterior doors have been installed | |||
| ALL ROUGH | 01/30/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1/30/26 1. Ufer p-ring needs to be oved so ufer connection is accessiable 2. Dryer duct seams (at change of direction) must be sealed 3. Low voltage panel missing outlet box 4. Outlet box missing in master bathroom 5. No windows or SGD installed 6. Kitchen sink drain requires N/P at bottom plate 7. Seal slab at tub drain 8. Master bathroom exhaust fan needs to be supported properly (has a belly) | |||
| ROOF VALLEY & METAL | 01/23/2026 | APPROVED | BTAYLOR |
| WALL SHEATHING | 01/16/2026 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/16/2026 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING | 01/16/2026 | APPROVED | MCONTRYMAN |
| ELECTRIC-TUG | 01/16/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 1/16/26 Email sent to FPL | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/15/2026 | APPROVED | RRICKS |
| GRAVITY SEWER TEST | 01/07/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/7/2026 2:18:27 PM *** | |||
| MONOLITHIC SLAB | 01/07/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/7/2026 2:02:36 PM *** 1/7/26: This inspection was completed on 1/5/26 while Inspection (server) system was down with technical complications.. RS | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 12/31/2025 | APPROVED | PBUCKLEY |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/31/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/31/2025 2:53:32 PM *** | |||
| WATER METER INSTALLATION REQUEST | 12/17/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/15/2026 | 04/15/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/09/2026 | 04/09/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| RSI | COMPLETE | 04/09/2026 | 04/14/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/15/2026 | 01/15/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/15/2026 | 01/15/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/31/2025 | 12/31/2025 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/19/2025 | 12/19/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/14/2025 | 10/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/11/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/11/2025 | 09/18/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) BOTH SIDE DRAINAGE PATTERNS NEED TO BE ON THE RIGHT AND LEFT PROPERTY LINES DUE TO THE VACANTS. 2) ALL RIGHT OF WAY/ FRONT PROPERTYLINE ELEVATIONS NEED TO BE EQUAL OR GREATER THEN THE EDGE OF PAVEMENT SO WATER WILL NOT BACK UP IN TO THE LOT DUE BIG RAIN EVENTS. | |||
| ZON | COMPLETE | 09/11/2025 | 09/11/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/24/2025 | 02/28/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/24/2025 | 02/28/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/24/2025 | 02/28/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/24/2025 | 02/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/24/2025 | 02/26/2025 |
| LOCATE | COMPLETE | 02/24/2025 | 03/03/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/24/2025 | 02/26/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/24/2025 | 02/25/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/24/2025 | 02/25/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/24/2025 | 03/03/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| PLC | COMPLETE | 02/24/2025 | 03/06/2025 |
| Note: Released By: ESTELLE LENS - (386)986-2655 - ELENS@PALMCOASTGOV.COM PLSW & UD1 reviews completed on prior permit |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/16/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 04/16/2026 |
| EXTENSION | ¤40.00 | 04/16/2026 |
| EXTENSION | ¤40.00 | 04/16/2026 |
| INSPECTION - RESIDENTIAL | ¤792.00 | 03/14/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤224.64 | 03/14/2025 |
| WATER- TURN ON | ¤25.00 | 03/14/2025 |
| ADJUSTMENT 10% | (¤104.66) | 03/14/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/14/2025 |
| SURCHARGE FS 533.721 | ¤9.42 | 03/14/2025 |
| SURCHARGE - FS 468.631 | ¤14.13 | 03/14/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/14/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/14/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/14/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/14/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/14/2025 |
| SEWER INSPECTION | ¤25.00 | 03/14/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 03/14/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 03/14/2025 |
| SITE PLAN 30 | ¤30.00 | 03/14/2025 |
| CONNECTION FEES | ¤1,187.26 | 03/14/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 03/14/2025 |
| IMPACT FEE FIRE | ¤434.51 | 03/14/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/14/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/14/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 03/14/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/14/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 03/14/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/14/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,523.47 |