I want to search for...
Permit #2025021366
Permit Details
Status: COED
| Parcel Id: 07-11-31-7021-00120-0110 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00120 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 20 WELLER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/06/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES, LLC |
|
Address 581 NW MERCANTILE PL PORT SAINT LUCIE, FL 34986 |
|
Address SUITE 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/24/2025 | FINAL APPROVED | MKRASKI |
| ROW - FINAL APRON (AFTER POUR) | 06/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 06/20/25 TPOLACEK**** APPROVING FIELD AS NOTED THAT ALL NOTES IN STORMWATER FINAL WILL BE ADDRESSED BEFORE REQUESTING FINAL ROW INSPECTION UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 06/20/25 TPOLACEK**** APPROVING FIELD AS NOTED THAT ALL NOTES IN STORMWATER FINAL WILL BE ADDRESSED BEFORE REQUESTING FINAL ROW INSPECTION UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 06/24/2025 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 No IRR. No cc | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/20/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/20/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 06/20/25 TPOLACEK**** APPROVING FIELD AS NOTED THAT ALL NOTES IN STORMWATER FINAL WILL BE ADDRESSED BEFORE REQUESTING FINAL ROW INSPECTION UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 06/17/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 10:45am | |||
| INSULATION | 06/03/2025 | APPROVED | MKRASKI |
| INSULATION | 06/02/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: Not ready, also make address visible from road per FBC 319.1 Inspector Notes from Inspection 2420 1. Address must be visible from road per by next inspection FBC 319.1 | |||
| ROW- PRE-APRON (PRE-POUR) | 06/02/2025 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ALL ROUGH | 05/30/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Address must be visible from road per by next inspection FBC 319.1 | |||
| LATH/BRICK/ WATER BARRIER | 05/29/2025 | APPROVED | MKRASKI |
| ALL ROUGH | 05/29/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Must have a full set of plans, e-cals, product approval, etc. onsite with the Building Dept. stamp of approval for inspection. FBC 107.3.1 ***Full re-inspection required*** | |||
| ALL ROUGH | 05/28/2025 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 05/28/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: via text 5/27/2025 - PREVIOUS INSPECTION NOTES 5/27/24 1. Multiple exterior penitrations in block require water barrier/lath FBC (A)107.4 5/23/2025 - PREVIOUS INSPECTION NOTES Not ready for inspection FBC (A)107.4 | |||
| GRAVITY SEWER TEST | 05/28/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 05/28/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ALL ROUGH | 05/27/2025 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 05/27/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 5/27/24 1. Multiple exterior penitrations in block require water barrier/lath FBC (A)107.4 5/23/2025 - PREVIOUS INSPECTION NOTES Not ready for inspection FBC (A)107.4 | |||
| LATH/BRICK/ WATER BARRIER | 05/23/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: Not ready for inspection FBC (A)107.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/22/2025 | APPROVED | MKRASKI |
| U-CROSS CONNECTION | 05/21/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: No IRR. No cc | |||
| ROOF VALLEY & METAL | 05/19/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/19/25 1. Trusses have proper spacing on top for sheathing, but they are about 2"-3" off plumb. Please have engineered letter, or fix prior to moving on with any interior work | |||
| WALL SHEATHING | 05/19/2025 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 1. Trusses have proper spacing on top for sheathing, but they are about 2"-3" off plumb. Please have engineered letter, or fix prior to moving on with any interior work | |||
| ROW - DRAINAGE | 05/19/2025 | APPROVED | TPOLACEK |
| Note: 05/19/25 TPOLACEK*** AT THE TIME OF THE INSPECTION THE SILT FRENCE IS UP AND PRE GRADE HAS BEEN COMPLETED. BUILDER WILL BE GOING TO FINAL GRADE SOON. 5/16/25= Tom Neighbor is complaining that the silt fence is down. Picture is attached to the permit. | |||
| TIE BEAM / LINTEL | 05/12/2025 | APPROVED | MCONTRYMAN |
| ROW- PROJECT STATUS | 05/08/2025 | Status Check | TPOLACEK |
| Note: 05/08/25 TPOLACEK*** MET WITH HOMEOWNER AND THERE IS STILL ONE IRRIGATION HEAD MISSING CAUSEING SYSTEM TO NOT BUILD PRESSURE. WILL CALL CM NOW TO DISCUSS REPLACEMENT ASAP. 5/7/25=Tom, can you please meet with the homeowner at 16 Weller Ln? The builder was supposed to fill the hole on her side of the property and repair the sprinkler head. She stated that they started the job but never finished it. | |||
| MONOLITHIC SLAB | 05/05/2025 | APPROVED | MCONTRYMAN |
| Note: 5/2/2025 - PREVIOUS INSPECTION NOTES Via text | |||
| MONOLITHIC SLAB | 05/02/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Via text | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/30/2025 | APPROVED | MGIBSON |
| ROW - DRAINAGE | 04/29/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++ 4/25/2025 - PREVIOUS INSPECTION NOTES 04/25/25 TPOLACEK*** SPOKE WITH CM ABOUT IRRIGATION HEAD ALONG #18 MUST BE FIXED TODAY, SILT FENCE STILL NEEDS TO BE DUG IN ON RIGHT SIDE. WILL BE BACK TUESDAY. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/25= IF THE CORRECTION IS NOT IN PLACE TOMORROW, WE WILL ADD A STOP WORK ORDER ON SITE 4/23/2025 - PREVIOUS INSPECTION NOTES= PER GBERTOLA 04/23/25 TPOLACEK*** GRADER IS WORKING ON CORRECTIONS. WILL GIVE BUILDER ONE MORE DAY TO RESOLVE ISSUES. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/21/2025 - PREVIOUS INSPECTION NOTES 04/21/25 TPOLACEK*** PLEASE SEE ATTACHED PHOTO OF PROPER REQUIRED SILT FENCE INSTALLATION. PERMIT IS BEING PLACED ON HOLD UNTIL SILT FENCE IS INSTALLED CORRECTLY. WILL RETURN ON WED 04/23/25 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2025 - PREVIOUS INSPECTION NOTES ALL STILL NEED TO BE ADDRESSED BY MONDAY OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. ----------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 04/25/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/25/25 TPOLACEK*** SPOKE WITH CM ABOUT IRRIGATION HEAD ALONG #18 MUST BE FIXED TODAY, SILT FENCE STILL NEEDS TO BE DUG IN ON RIGHT SIDE. WILL BE BACK TUESDAY. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/25= IF THE CORRECTION IS NOT IN PLACE TOMORROW, WE WILL ADD A STOP WORK ORDER ON SITE 4/23/2025 - PREVIOUS INSPECTION NOTES= PER GBERTOLA 04/23/25 TPOLACEK*** GRADER IS WORKING ON CORRECTIONS. WILL GIVE BUILDER ONE MORE DAY TO RESOLVE ISSUES. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/21/2025 - PREVIOUS INSPECTION NOTES 04/21/25 TPOLACEK*** PLEASE SEE ATTACHED PHOTO OF PROPER REQUIRED SILT FENCE INSTALLATION. PERMIT IS BEING PLACED ON HOLD UNTIL SILT FENCE IS INSTALLED CORRECTLY. WILL RETURN ON WED 04/23/25 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2025 - PREVIOUS INSPECTION NOTES ALL STILL NEED TO BE ADDRESSED BY MONDAY OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. ----------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 04/23/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/23/25 TPOLACEK*** GRADER IS WORKING ON CORRECTIONS. WILL GIVE BUILDER ONE MORE DAY TO RESOLVE ISSUES. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/21/2025 - PREVIOUS INSPECTION NOTES 04/21/25 TPOLACEK*** PLEASE SEE ATTACHED PHOTO OF PROPER REQUIRED SILT FENCE INSTALLATION. PERMIT IS BEING PLACED ON HOLD UNTIL SILT FENCE IS INSTALLED CORRECTLY. WILL RETURN ON WED 04/23/25 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2025 - PREVIOUS INSPECTION NOTES ALL STILL NEED TO BE ADDRESSED BY MONDAY OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. ----------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 04/21/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/21/25 TPOLACEK*** PLEASE SEE ATTACHED PHOTO OF PROPER REQUIRED SILT FENCE INSTALLATION. PERMIT IS BEING PLACED ON HOLD UNTIL SILT FENCE IS INSTALLED CORRECTLY. WILL RETURN ON WED 04/23/25 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2025 - PREVIOUS INSPECTION NOTES ALL STILL NEED TO BE ADDRESSED BY MONDAY OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. ----------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 04/17/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: ALL STILL NEED TO BE ADDRESSED BY MONDAY OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. ----------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/17/2025 | APPROVED | RRICKS |
| ROW- PROJECT STATUS | 04/14/2025 | Status Check | PFLANAGAN |
| Note: met with homeowner | |||
| ROW - DRAINAGE | 04/14/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: NEED TO CORRECT THE FOLLOWING 1) NEED TO INSTALL SILT FENCE CORRECTLY NEED TO TRENCH SILT FENCE AT A MINIMUM OF 6" SO SEDIMENT WILL STAY ON SITE. 2) YOU NEED TO FILL IN THE HOLE ON RIGHT SIDE ON THE LOT AND ON THE ADJACENT LOT AND YOU WILL BE REQUIRED TO SOD ALL BARE AREAS. YOU WILL HAVE 5 DAY INTILL NEXT INSPECTION OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/11/2025 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 04/04/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 04/17/2025 | 04/17/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/17/2025 | 04/17/2025 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/10/2025 | 04/11/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/05/2025 | 03/05/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/05/2025 | 03/05/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/05/2025 | 03/06/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/27/2025 | 03/05/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/27/2025 | 03/05/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/27/2025 | 02/28/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/27/2025 | 03/03/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 02/27/2025 | 02/27/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Culvert pipe does not require a bend in this area. Typically, the 22.5 degree bend is only required in cul-de-sacs and curves that have a distance of 10' from the edge of pavement to the property line. | |||
| GAS | CANCEL | 02/27/2025 | 03/04/2025 |
| LOCATE | COMPLETE | 02/27/2025 | 03/04/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/27/2025 | 03/04/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/27/2025 | 02/28/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Move berm in the rear to the easement so less water is impacting lots in the rear. | |||
| ZON | HOLD | 02/27/2025 | 02/27/2025 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SITE PLAN MISSING WALKWAY MATERIAL/DIMENSIONS | |||
| SWALE | COMPLETE | 02/27/2025 | 03/04/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 06/20/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/06/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/06/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/06/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/06/2025 |
| SEWER CREDIT | (¤850.00) | 03/06/2025 |
| SEWER INSPECTION | ¤25.00 | 03/06/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 03/06/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 03/06/2025 |
| SITE PLAN 30 | ¤30.00 | 03/06/2025 |
| CONNECTION FEES | ¤1,187.26 | 03/06/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 03/06/2025 |
| IMPACT FEE FIRE | ¤434.51 | 03/06/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/06/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/06/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 03/06/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/06/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 03/06/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/06/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 03/06/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 03/06/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/06/2025 |
| WATER- TURN ON | ¤25.00 | 03/06/2025 |
| ADJUSTMENT 10% | (¤120.20) | 03/06/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/06/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 03/06/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 03/06/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,849.25 |