I want to search for...

Permit #2025021374

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00080-0020
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00080
Subdivision: -
Job Phone: 239-571-5325
Location Address: 12 REINDEER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/05/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES LLC

Address

581 NW MERCANTILE PLACE 106

PORT SAINT LUCIE, FL 34986

Lot: 0020
Contracted Stated Job Value: ¤200,000.00
Job Description: Single Family Residence
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
ROW- PROJECT STATUS 08/04/2025 CANCELLED BY INSPECTOR GBERTOLA
ROW- PROJECT STATUS 07/29/2025 Status Check EMADISON
Note: ** 07/29/25 LEFT SIDE BERM IN AREA OF FENCE BERM FLATENS OUT NEEDS TO RAISE IN AREA WHERE THE PINK PAINT WAS SPRAYED APROXIMATELY A 6 FT LONG SPOT . ** ON BOTH SIDES OF THE FENCE NEED TO OPEN (REMOVE THE DIRT) OUT OF THE INSIDE SWALE DRAINAGE THAT GOES BENEATH THE FENCE ** AREA ACROSS LEFT REAR NEED TO BUILD UP BERM SO THAT THE TOP OF BERM IS .30 HIGHER THAN THE BOTTOM OF BERM, FROM LEFT REAR CORNER OUT APPROXIMATELY 20 FT WHERE AREA WHERE SOME WORK WAS ALREADY DONE ** LEFT SIDE AND RIGHT SIDE AT CULVERT PIPE BUILDER NEEDS TO CREATE A 2:1 SLOPE AT BOTH CULVERT ENDS _______________________________________________________________________________________________________________ During a recent meeting at the construction site with the inspectors, it was noted that the berm on the left side of the house has disappeared, which is now impacting the homeowner at property 10 due to stormwater issues. The builder has been tasked with reestablishing the berm and adding a swale on the inside to manage the stormwater flow effectively. Also, the front swale on the left side facing the house is too high, which stops the flow of stormwater. Thank you.
ROW- PROJECT STATUS 07/22/2025 Status Check TPOLACEK
Note: *** NOTES ADDED BY GBERTOLA 7/29/2025 8:16:31 AM *** During a recent meeting at the construction site with the inspectors, it was noted that the berm on the left side of the house has disappeared, which is now impacting the homeowner at property 10 due to stormwater issues. The builder has been tasked with reestablishing the berm and adding a swale on the inside to effectively manage the stormwater flow. 07/28/25 TPOLACEK** CHECKED SITE CONDITIONS AND BUILDER HAS NOT MADE CORRECTIONS AT THIS TIME. BUILDER HAS 1 WEEK TO MAKE CORRECTIONS
U -UTILITY RESIDENTIAL FINAL 06/25/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irr-no cc
ROW - FINAL APRON (AFTER POUR) 06/24/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/24/2025 APPROVED TPOLACEK
Note: 6/23/2025 - PREVIOUS INSPECTION NOTES 06/23/25 TPOLACEK*** DRIVEWAY CULVERT IS STILL SHOWING MORE THAN THE ALLOWED .10 +/- FROM THE SWALE PLAN DETAIL. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow 6/17/2025 - PREVIOUS INSPECTION NOTES 06/17/25 TPOLACEK** FINAL SURVEY INDICATES RIGHT SIDE OF CULVERT IS OUT OF TOLERENCE, BACK YARD DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPOERTY TO THE REAR, LEFT SIDE PROPERTY LINE DOES NOT HAVE THE REQUIRED .10 OF FALL EVERY 20'. SWALE PLAN 1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StorrnwaterEngineer). The finished swale elevation is with sod in place. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ROW FIELD SURVEY /GRADING CERTIFICATION 06/24/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 06/24/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/23/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 06/23/25 TPOLACEK*** DRIVEWAY CULVERT IS STILL SHOWING MORE THAN THE ALLOWED .10 +/- FROM THE SWALE PLAN DETAIL. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow 6/17/2025 - PREVIOUS INSPECTION NOTES 06/17/25 TPOLACEK** FINAL SURVEY INDICATES RIGHT SIDE OF CULVERT IS OUT OF TOLERENCE, BACK YARD DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPOERTY TO THE REAR, LEFT SIDE PROPERTY LINE DOES NOT HAVE THE REQUIRED .10 OF FALL EVERY 20'. SWALE PLAN 1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StorrnwaterEngineer). The finished swale elevation is with sod in place. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/17/2025 Disapproved - NO FEE TPOLACEK
Note: 06/17/25 TPOLACEK** FINAL SURVEY INDICATES RIGHT SIDE OF CULVERT IS OUT OF TOLERENCE, BACK YARD DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPOERTY TO THE REAR, LEFT SIDE PROPERTY LINE DOES NOT HAVE THE REQUIRED .10 OF FALL EVERY 20'. SWALE PLAN 1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StorrnwaterEngineer). The finished swale elevation is with sod in place. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet
BLD - BUILDING FINAL 06/17/2025 CANCELLED BY APPLICANT WEB
Note: 6/13/2025 - PREVIOUS INSPECTION NOTES 6/13/25 1. Sewer cap is cut open 2. Missing weather stripping on entry doors (garage and front doors) FBC 402.5.1.1 3. No hot water FBCR P2722.2 4. Construction debris in garage 5. AH breaker size does not match unit NEC 440.4 6. Kitchen sink is missing joint blocking in between cabinet doors 7. No insulation certificate or blower door test 8. No address posted FBCR 319.1
BLD - BUILDING FINAL 06/17/2025 APPROVED CVANSTRAHLEN
Note:
BLD - BUILDING FINAL 06/13/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 6/13/25 1. Sewer cap is cut open 2. Missing weather stripping on entry doors (garage and front doors) FBC 402.5.1.1 3. No hot water FBCR P2722.2 4. Construction debris in garage 5. AH breaker size does not match unit NEC 440.4 6. Kitchen sink is missing joint blocking in between cabinet doors 7. No insulation certificate or blower door test 8. No address posted FBCR 319.1
GRAVITY SEWER TEST 06/09/2025 APPROVED MGIBSON
Note: 6/3/2025 - PREVIOUS INSPECTION NOTES
SEWER TIE IN 06/09/2025 APPROVED MGIBSON
Note: 6/3/2025 - PREVIOUS INSPECTION NOTES
ELECTRIC - EARLY POWER 06/06/2025 APPROVED CVANSTRAHLEN
Note:
ROW- PRE-APRON (PRE-POUR) 06/06/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 6/4/2025 - PREVIOUS INSPECTION NOTES 06/04/25 TPOLACEK*** IT IS THE BUILDERS RESPOSIBILITY TO CHECK SITE PRIOR TO INSPECTION AND CANCEL INSPECTION IF SITE IS NOT READY. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. 6/2/2025 - PREVIOUS INSPECTION NOTES 06/02/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++ 5/29/2025 - PREVIOUS INSPECTION NOTES 05/29/25 TPOLACEK*** CANCELING PER CONVERSATION WITH CM Inspector Notes from Inspection 9470 ** 05/28/25 ALL CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ______________________________________________________________________________________________________________________ Note to the inspector: Please inspect the front swale and check for any obstructions that may be preventing the proper flow of water.Per Gbertola
ROW- PRE-APRON (PRE-POUR) 06/04/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 06/04/25 TPOLACEK*** IT IS THE BUILDERS RESPOSIBILITY TO CHECK SITE PRIOR TO INSPECTION AND CANCEL INSPECTION IF SITE IS NOT READY. NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. 6/2/2025 - PREVIOUS INSPECTION NOTES 06/02/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++ 5/29/2025 - PREVIOUS INSPECTION NOTES 05/29/25 TPOLACEK*** CANCELING PER CONVERSATION WITH CM Inspector Notes from Inspection 9470 ** 05/28/25 ALL CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ______________________________________________________________________________________________________________________ Note to the inspector: Please inspect the front swale and check for any obstructions that may be preventing the proper flow of water.Per Gbertola
ELECTRIC - EARLY POWER 06/03/2025 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: cancelled by text
SEWER TIE IN 06/03/2025 CANCELLED BY APPLICANT MGIBSON
GRAVITY SEWER TEST 06/03/2025 CANCELLED BY APPLICANT MGIBSON
ROW- PROJECT STATUS 06/03/2025 Status Check EMADISON
Note: ** DISCUSS WITH NEIGHBOR AT 10 REINDEER LN HIS CONCERNS THAT THAT 12 REINDEER LN WILL HOLD BACK WATER IN THE ROADSIDE SWALE. The final grade has not been completed at the time I was there however there has been some final grade and sod has already been set on most of the property except for the right side of the property from the right rear corner of the structure out to the edge of road. The elevation in the swale appears to raise as the swale is holding back water on the right side. I had explained to the resident from 10 Reindeer Ln that the final series of inspections will not be approved if theY show that the new construction property is restricting the flow of water. I also spoke with the construction site manager, who indicated they would make every attempt to ensure that the roadside swale with be graded correctly before prior to submitting a final survey.
ROW- PRE-APRON (PRE-POUR) 06/02/2025 CANCELLED BY APPLICANT TPOLACEK
Note: 06/02/25 TPOLACEK*** RECIEVED TEXT FROM CM ASKING TO CANCEL INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++ 5/29/2025 - PREVIOUS INSPECTION NOTES 05/29/25 TPOLACEK*** CANCELING PER CONVERSATION WITH CM Inspector Notes from Inspection 9470 ** 05/28/25 ALL CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ______________________________________________________________________________________________________________________ Note to the inspector: Please inspect the front swale and check for any obstructions that may be preventing the proper flow of water.Per Gbertola
ROW- PRE-APRON (PRE-POUR) 05/29/2025 CANCELLED BY APPLICANT TPOLACEK
Note: 05/29/25 TPOLACEK*** CANCELING PER CONVERSATION WITH CM Inspector Notes from Inspection 9470 ** 05/28/25 ALL CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ______________________________________________________________________________________________________________________ Note to the inspector: Please inspect the front swale and check for any obstructions that may be preventing the proper flow of water.Per Gbertola
ROW- PRE-APRON (PRE-POUR) 05/28/2025 CANCELLED BY APPLICANT EMADISON
Note: ** CANCELLED BY CM (GRAYSON) SITE TOO WET
PEP TANK INSTALLATION REQUEST 05/28/2025 APPROVED CBOWERMASTER
Note: 5/22/2025 8:16:24 AM- PREVIOUS INSPECTION NOTES stucco needs to be complete
ROW - DRAINAGE 05/28/2025 APPROVED - AS NOTED EMADISON
Note: ** 05/28/25 ALL CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ______________________________________________________________________________________________________________________ Note to the inspector: Please inspect the front swale and check for any obstructions that may be preventing the proper flow of water.Per Gbertola
PEP TANK INSTALLATION REQUEST 05/21/2025 Disapproved -FEE REQUIRED CBOWERMASTER
Note: stucco needs to be complete
INSULATION 05/20/2025 APPROVED CVANSTRAHLEN
U-CROSS CONNECTION 05/20/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
LATH/BRICK/ WATER BARRIER 05/19/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 05/16/2025 APPROVED CVANSTRAHLEN
LATH/BRICK/ WATER BARRIER 05/16/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: nothing done
ROOF VALLEY & METAL 05/12/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 05/09/2025 CANCELLED BY APPLICANT WEB
WALL SHEATHING 05/08/2025 CANCELLED BY INSPECTOR CVANSTRAHLEN
Note: do not need it
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/08/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 05/08/2025 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 05/01/2025 APPROVED CVANSTRAHLEN
MONOLITHIC SLAB 04/23/2025 APPROVED MCONTRYMAN
PLUMBING 1ST ROUGH UNDERGROUND 04/21/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/17/2025 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 04/14/2025 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 04/01/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 04/17/2025 04/17/2025
Note: Released By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/11/2025 04/14/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/11/2025 04/11/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 02/27/2025 03/05/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 02/27/2025 03/05/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 02/27/2025 02/28/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 02/27/2025 03/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/27/2025 02/27/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/27/2025 03/04/2025
LOCATE COMPLETE 02/27/2025 03/04/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 02/27/2025 03/04/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/27/2025 02/28/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/27/2025 02/28/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SWALE COMPLETE 02/27/2025 03/05/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/24/2025
SW ENG - INSPECTION 20 ¤20.00 06/24/2025
SW ENG REINSPECTION 30 ¤30.00 06/24/2025
UTILITY PEP REINSPECTION ¤40.00 06/24/2025
SEWER CREDIT (¤1,466.00) 03/05/2025
SEWER INSPECTION ¤25.00 03/05/2025
SEWER CAPITAL FACILITY ¤6,120.52 03/05/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 03/05/2025
SITE PLAN 30 ¤30.00 03/05/2025
SW ENG - REVIEW 20 ¤20.00 03/05/2025
SW ENG RES REVIEW 200 ¤200.00 03/05/2025
SW ENG INSPECTION 80 ¤80.00 03/05/2025
SW ENG PRE APRON ¤30.00 03/05/2025
WATER- TURN ON ¤25.00 03/05/2025
ADJUSTMENT 10% (¤120.20) 03/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/05/2025
INSPECTION - RESIDENTIAL ¤913.00 03/05/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 03/05/2025
CONNECTION FEES ¤1,187.26 03/05/2025
FC IMPACT FEE EMS ¤62.00 03/05/2025
IMPACT FEE FIRE ¤434.51 03/05/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/05/2025
FC IMPACT FEE LIBRARY ¤268.00 03/05/2025
IMPACT FEE PARKS ¤1,828.01 03/05/2025
IMPACT FEE SCHOOL ¤5,450.00 03/05/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 03/05/2025
WATER -IRRIGATION INSPECTION ¤25.00 03/05/2025
SURCHARGE FS 533.721 ¤10.82 03/05/2025
SURCHARGE - FS 468.631 ¤16.23 03/05/2025
SW ENG - FOUNDATION SURVEY ¤20.00 03/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤22,063.25