I want to search for...
Permit #2025030071
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01300-0130 |
| Block: 01300 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-503-6922 |
| Location Address: 10 EDISON LN |
| Type: PO - POOL |
| Issue Date: 03/25/2025 |
| NOC: RECORDED |
| Applicant name: JOSE E ORTIZ JR |
| Owner: THOMPSON JAMES MICHAEL & PATRICIA MARY TRUSTEES |
|
Address 10 EDISON LANE PALM COAST, FL 32164 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: Pool build |
| Type: CN |
Contractor
JOSE E ORTIZ JR LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD A3 PALM COAST, FL 32164 |
CPC1460694 (Exp: 08/31/2026) | 386-313-6055 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
RICHARD SWAN TOWNSEND II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3111 OPPORTUNITY CT SUITE D PORT ORANGE, FL 32129 |
CGC1515792 (Exp: 08/31/2026) | 386-756-8770 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 05/01/2026 | FINAL APPROVED | HCAMACHO |
| ROW - FINAL INSPECTION | 04/10/2026 | APPROVED | FSLADISH |
| Note: 4/10/26 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. ____________________________________________________________________________________________________________________________ 3/6/2026 - PREVIOUS INSPECTION NOTES 3/6/26 BUILDER CALLED AND ASKED TO PLEASE CANCEL THIS INSPECTION FOR TODAY. Inspector Notes from Inspection 9465 Inspector Notes from Inspection 9463 3/4/26 AS THIS SURVEY HAS FAILED TWICE WHILE I WAS IN THE AREA STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSE ANOMOLIES IS THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSECTION AND AM APPROVING THIS SURVEY AS NOTED. 2/25/2026 - PREVIOUS INSPECTION NOTES 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 3/4/26 I WAS IN THE AREA, SO I STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE DUE TO SURVEY FAILING TWICE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSED ANOMOLIES WITH THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION AND AM APPROVING THIS FIELD SURVEY AS NOTED THAT THE FRONT SWALE WHERE ENTRY AND EXIT WAS USED WILL NEED TO BE CORRECTED. BUILDER IS REQUIRED TO DIG OUT HIGH BARE SPOT IN COPC ROW AND MAKE SURE WHEN SOD IS LAID IN THIS AREA IT MATCHES GRADE ON BOTH SIDES OF ENTRY POINT. THIS CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. AREA OUTLINED IN PAINT. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/06/2026 | FINAL APPROVED | BWRIGHT |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/06/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/6/26 This is a duplicate inspection passed on 3/5/26. approving as noted. Inspector Notes from Inspection 9465 Inspector Notes from Inspection 9463 3/4/26 AS THIS SURVEY HAS FAILED TWICE WHILE I WAS IN THE AREA STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSE ANOMOLIES IS THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSECTION AND AM APPROVING THIS SURVEY AS NOTED. 2/25/2026 - PREVIOUS INSPECTION NOTES 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 3/4/26 I WAS IN THE AREA, SO I STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE DUE TO SURVEY FAILING TWICE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSED ANOMOLIES WITH THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION AND AM APPROVING THIS FIELD SURVEY AS NOTED THAT THE FRONT SWALE WHERE ENTRY AND EXIT WAS USED WILL NEED TO BE CORRECTED. BUILDER IS REQUIRED TO DIG OUT HIGH BARE SPOT IN COPC ROW AND MAKE SURE WHEN SOD IS LAID IN THIS AREA IT MATCHES GRADE ON BOTH SIDES OF ENTRY POINT. THIS CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. AREA OUTLINED IN PAINT. | |||
| ROW - FINAL INSPECTION | 03/06/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/6/26 BUILDER CALLED AND ASKED TO PLEASE CANCEL THIS INSPECTION FOR TODAY. Inspector Notes from Inspection 9465 Inspector Notes from Inspection 9463 3/4/26 AS THIS SURVEY HAS FAILED TWICE WHILE I WAS IN THE AREA STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSE ANOMOLIES IS THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSECTION AND AM APPROVING THIS SURVEY AS NOTED. 2/25/2026 - PREVIOUS INSPECTION NOTES 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 3/4/26 I WAS IN THE AREA, SO I STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE DUE TO SURVEY FAILING TWICE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSED ANOMOLIES WITH THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION AND AM APPROVING THIS FIELD SURVEY AS NOTED THAT THE FRONT SWALE WHERE ENTRY AND EXIT WAS USED WILL NEED TO BE CORRECTED. BUILDER IS REQUIRED TO DIG OUT HIGH BARE SPOT IN COPC ROW AND MAKE SURE WHEN SOD IS LAID IN THIS AREA IT MATCHES GRADE ON BOTH SIDES OF ENTRY POINT. THIS CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. AREA OUTLINED IN PAINT. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/05/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/4/26 AS THIS SURVEY HAS FAILED TWICE WHILE I WAS IN THE AREA STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSE ANOMOLIES IS THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSECTION AND AM APPROVING THIS SURVEY AS NOTED. 2/25/2026 - PREVIOUS INSPECTION NOTES 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/05/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: *** NOTES ADDED BY FSLADISH 3/5/2026 12:04:16 PM *** 3/4/26 I WAS IN THE AREA, SO I STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE DUE TO SURVEY FAILING TWICE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSED ANOMOLIES WITH THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION AND AM APPROVING THIS FIELD SURVEY AS NOTED THAT THE FRONT SWALE WHERE ENTRY AND EXIT WAS USED WILL NEED TO BE CORRECTED. BUILDER IS REQUIRED TO DIG OUT HIGH BARE SPOT IN COPC ROW AND MAKE SURE WHEN SOD IS LAID IN THIS AREA IT MATCHES GRADE ON BOTH SIDES OF ENTRY POINT. THIS CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. AREA OUTLINED IN PAINT. Inspector Notes from Inspection 9463 3/4/26 AS THIS SURVEY HAS FAILED TWICE WHILE I WAS IN THE AREA STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSE ANOMOLIES IS THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSECTION AND AM APPROVING THIS SURVEY AS NOTED. 2/25/2026 - PREVIOUS INSPECTION NOTES 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." 3/4/26 I WAS IN THE AREA, SO I STOPPED BY TO CONDUCT A FIELD SURVEY TO INVESTIGATE GRADE DUE TO SURVEY FAILING TWICE. DUE TO ROCK BEING USED AROUND REAR OF POOL DETERMINED IT MAY HAVE CAUSED ANOMOLIES WITH THE ELEVATION SHOTS. I HAVE DETERMINED THAT DRAINAGE WILL WORK AT THE TIME OF THIS INSPECTION AND AM APPROVING THIS FIELD SURVEY AS NOTED THAT THE FRONT SWALE WHERE ENTRY AND EXIT WAS USED WILL NEED TO BE CORRECTED. BUILDER IS REQUIRED TO DIG OUT HIGH BARE SPOT IN COPC ROW AND MAKE SURE WHEN SOD IS LAID IN THIS AREA IT MATCHES GRADE ON BOTH SIDES OF ENTRY POINT. THIS CORRECTION WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. AREA OUTLINED IN PAINT. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/25/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 2/25/26 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR OF THE POOL DECK ON THIS SURVEY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING POOL DECK. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." PLEASE SEE PHOTO FOR REFERENCE. 12/16/2025 - PREVIOUS INSPECTION NOTES 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/16/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 12/16/25 YOUR SURVEY DOES NOT MATCH YOUR SITE PLAN. YOUR SITE PLAN SHOWS DRAINAGE OF OF REAR POOL DECK FLOWING RIGHT AND LEFT TRHU A SWALE, YOUR SURVEY SHOWS DRAINAGE ALL RUNNING TO THE REAR NEIGHBORING PROPERTY. YOU MAY NOT HAVE ADVERSE DRAINAGE AFFECTING ADJACENT PROPERTY. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." | |||
| ELECTRIC AND ALARM | 07/03/2025 | APPROVED | CVANSTRAHLEN |
| POOL DECK | 05/22/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| POOL DECK | 05/21/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Perimeter bondn wire for 4 points of bonding of pool steel missing NEC 680.26.4 2. Please have footing plans on site with Building Dept. stamp of approval for next inspection FBC 107.3.1 | |||
| POOL DECK | 05/13/2025 | CANCELLED BY APPLICANT | WEB |
| STEEL AND GROUND | 03/31/2025 | APPROVED | MCONTRYMAN |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 03/20/2026 | 03/20/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/24/2026 | 02/24/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM CAN NOT SCHEDULE FINAL SURVEY INSPECTION. NOC EXPIRED 1/17/2026 | |||
| ZON | COMPLETE | 03/20/2025 | 03/20/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/20/2025 | 03/21/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/20/2025 | 03/25/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BFLOOD | COMPLETE | 03/03/2025 | 03/05/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/03/2025 | 03/07/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Need pool plans uploaded. 2. Need 3rd pg of the TDH form. 3. If there is a screen, need plans. | |||
| ELEC | HOLD | 03/03/2025 | 03/07/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit pool plans | |||
| MECH | COMPLETE | 03/03/2025 | 03/05/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/03/2025 | 03/05/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/03/2025 | 03/04/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Screen plan dimensions do not match the pool deck dimensions. Screen would not meet the minimum rear setback at the size shown on plans |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 03/05/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/21/2025 |
| SURCHARGE FS 533.721 | ¤2.41 | 03/25/2025 |
| SURCHARGE - FS 468.631 | ¤3.62 | 03/25/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 03/25/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/25/2025 |
| SITE PLAN 30 | ¤30.00 | 03/25/2025 |
| INSPECTION- POOL | ¤160.00 | 03/25/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤78.00 | 03/25/2025 |
| ADJUSTMENT 10% | (¤26.80) | 03/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤452.23 |