I want to search for...

Permit #2025030163

Permit Details

Status: FINAL

Parcel Id: 23-11-30-6060-00000-00G0
Subdivision: -
Job Phone: 407-709-0054
Location Address: 300 WISTERIA HILL DR
Type: CRWALL - COMMERCIAL RETAINING WALL
Issue Date: 04/28/2025
NOC: RECORDED
Applicant name: CHARLES P MILLER JR
Owner: MARBELLA APARTMENTS LLC

Address

3060 PEACHTREE ROAD NW SUITE 970

ATLANTA, GA 30305

Contracted Stated Job Value: ¤7,500.00
Job Description: RETAINING WALL - WALL 1- 77 LF
Type: CN

Contractor

PAVERSCAPE INC
Status Location Address State License Number Phone Fax
ACTIVE

6895 BIG BEND DRIVE

ST CLOUD , FL 34771

CBC1253252 (Exp: 08/31/2028) 407-957-4215 407-957-6128

Inspection History

Type Request Date Result Inspector
FINAL 06/26/2025 FINAL APPROVED KSANDOE
Note: 6/20/2025 - PREVIOUS INSPECTION NOTES RETAINING WALL CONTINUES. COMPLETED SOUTHWEST CORNER ONLY.
LDSC- LANDSCAPE FINAL 06/20/2025 APPROVED RPICATAGI
FINAL 06/20/2025 PARTIALLY APPROVED FWILLIS
Note: RETAINING WALL CONTINUES. COMPLETED SOUTHWEST CORNER ONLY.
LINTEL 05/27/2025 APPROVED FWILLIS
RETAINING WALL FOUNDATION 05/23/2025 APPROVED FWILLIS
Note: 5/22/2025 - PREVIOUS INSPECTION NOTES
RETAINING WALL FOUNDATION 05/22/2025 CANCELLED BY APPLICANT FWILLIS
RETAINING WALL FOUNDATION 04/30/2025 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
BLD COMPLETE 04/17/2025 04/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 03/31/2025 04/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Comments need to added to the plan sheets or a letter. Letter needs to bee digitally signed and sealed by the engineer of record.
BLD HOLD 03/05/2025 03/17/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1.     Indicate soil lateral load per 1610.1. 2.     Has wall been designed for full hydrostatic pressure of undrained backfill?  If not provide drainage system per 1805.4.2 and 1805.4.3. or site Exception to 1610.1. 3.     Indicate wall has been designed per 1807.2.1 through 1807.2.3 with minimum safety factor of 1.5 for sliding and overturning. 
DSD COMPLETE 03/05/2025 03/19/2025
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
PLENG COMPLETE 03/05/2025 03/06/2025
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLLA COMPLETE 03/05/2025 03/20/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - COMMERCIAL ¤75.00 04/28/2025
INSPECTION COMMERCIAL ¤60.00 04/28/2025
PLAN REVIEW - COMMERCIAL ¤65.00 04/28/2025
SURCHARGE FS 533.721 ¤2.00 04/28/2025
SURCHARGE - FS 468.631 ¤3.00 04/28/2025
Fees Total Due: ¤0.00 Total Paid: ¤205.00