I want to search for...

Permit #2025030180

Permit Details

Status: FINAL

Parcel Id: 22-11-31-0000-02020-0200
Block: 02020
Subdivision: 0 -
Job Phone: (386)253-7774
Location Address: 2001 WATERSIDE PKWY
Type: HD - HOOD SYSTEM
Issue Date: 04/03/2025
NOC: Unknown
Applicant name: STEVEN KEITH JONES
Owner: GRAND HAVEN COMMUNITY DEV DISTRICT C/O DPFR MANAGE

Address

250 INTERNATIONAL PARKWAY

LAKE MARY, FL 32746

Address

SUITE 208

LAKE MARY, FL 32746

Lot: 0200
Contracted Stated Job Value: ¤35,000.00
Job Description: Grand Haven Cafe Kitchen hood install
Type: CN

Contractor

D G MEYER INC
Status Mailing Address State License Number Phone Fax
ACTIVE

345 MADISON AVE

DAYTONA BEACH, FL 32114

CMC057027 (Exp: 08/31/2026) (386)253-7774 (386)255-9431

Inspection History

Type Request Date Result Inspector
HOOD FINAL 05/22/2025 FINAL APPROVED CPISCITELLI
HOOD DUCT AND DUCT LIGHTING TEST 04/15/2025 APPROVED CPISCITELLI
HOOD ROUGH 04/15/2025 APPROVED CPISCITELLI
Note: 4/11/2025 - PREVIOUS INSPECTION NOTES Sill Need to inspect make up ductwork
HOOD DUCT AND LIGHTING TEST 04/11/2025 PARTIALLY APPROVED CPISCITELLI
Note: Only right side duct passed. Left side duct leaking at hood connection. Need to be rewelded
HOOD ROUGH 04/11/2025 PARTIALLY APPROVED CPISCITELLI
Note: Sill Need to inspect make up ductwork

Review History

Department Status Date In Date Out
MECH COMPLETE 03/27/2025 04/03/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 03/26/2025 03/27/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Hood checklist has wrong hood submittals in report. Provide checklist with correct hood submittals
MECH HOLD 03/05/2025 03/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS FROM FBC MECHANICAL 2023 1. Provide completed city of palm coast checklist from portal. AHJ 2. Hood shows clearance to combustibles of 18" on top. Provide zero clearance hood for application. 507.2.6 3. Provide hinge detail for exhaust fan 506.5.4 4. Provide manufacturers specs on two ovens. (Not shown under hood). Provide specs and layout for Type 2 hood required if they are light duty appliance. 507.3 5. Provide roof plan showing clearances and termination location 506.3.13.3 and 506.5.5-506.5.6 6. Provide note showing appliances 6 inches inside of hood 507.4.1

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤38.50) 04/03/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 04/03/2025
INSPECTION COMMERCIAL ¤245.00 04/03/2025
PLAN REVIEW - COMMERCIAL ¤65.00 04/03/2025
SURCHARGE FS 533.721 ¤3.47 04/03/2025
SURCHARGE - FS 468.631 ¤5.20 04/03/2025
Fees Total Due: ¤0.00 Total Paid: ¤355.17