I want to search for...

Permit #2025030413

Permit Details

Status: COED

Parcel Id: 07-11-31-7020-00020-0170
CONDITIONED SPACE: 1504 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 119 sqft
Total Square Footage: 2019 sqft
Block: 00020
Subdivision: -
Job Phone: 407-476-8195
Location Address: 24 WEYMOUTH LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/02/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LLC

Address

3670 MAGUIRE BOULEVARD

ORLANDO, FL 32803

Address

SUITE 220

ORLANDO, FL 32803

Lot: 0170
Contracted Stated Job Value: ¤150,000.00
Job Description: single family residence
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 03/24/2026 APPROVED RRICKS
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------------------------------------------------------- 3/18/2026 - PREVIOUS INSPECTION NOTES ** 03/18/26 YOUR HOT ASPHALT ROAD REPAIR PATCH IS B BROKEN AWAY, APPEARS SOMEONE DROVE ONTO IT BEFORE IT HAD TIME TO SET (LEFT SIDE OF DRIVEWAY) ** SEE PHOTO
U -UTILITY RESIDENTIAL FINAL 03/24/2026 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No cc, no irrigatiom
ROW - FINAL APRON (AFTER POUR) 03/18/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 03/18/2026 Disapproved - NO FEE EMADISON
Note: ** 03/18/26 YOUR HOT ASPHALT ROAD REPAIR PATCH IS B BROKEN AWAY, APPEARS SOMEONE DROVE ONTO IT BEFORE IT HAD TIME TO SET (LEFT SIDE OF DRIVEWAY) ** SEE PHOTO
BLD - BUILDING FINAL 03/18/2026 FINAL APPROVED HCAMACHO
U-CROSS CONNECTION 03/18/2026 APPROVED - AS NOTED BVEIGA
Note: No cc, no irrigatiom
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/06/2026 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 03/06/2026 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 02/26/2026 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2200 Emailed FPL @ 11:30am
ROW- PRE-APRON (PRE-POUR) 02/17/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
INSULATION 01/21/2026 APPROVED MKRASKI
INSULATION 01/20/2026 Disapproved - NO FEE MKRASKI
Note: 1/20/26 Item 2 not repaired, Tape/seal joint above top plate on dryer vent, Also dryer vent requires nail plate at top plate, Vent stack in same wall as dryer vent requires a nail plate as well. 1/14/26 1. Fire blocking required for dryer vent 2. Tape/seal joint above top plate on dryer vent 1/9/26 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 Make both repairs by insulation 12/17/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 5. Vent for kitchen sink missing, plans call for vent through the roof, highlighted on print ***Items 1, 2, and 3 are from previous inspection that have not been repaired*** 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
INSULATION 01/14/2026 Disapproved - NO FEE MKRASKI
Note: 1/14/26 1. Fire blocking required for dryer vent 2. Tape/seal joint above top plate on dryer vent 1/9/26 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 Make both repairs by insulation 12/17/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 5. Vent for kitchen sink missing, plans call for vent through the roof, highlighted on print ***Items 1, 2, and 3 are from previous inspection that have not been repaired*** 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ALL ROUGH 01/09/2026 APPROVED - AS NOTED MKRASKI
Note: 1/9/26 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 Make both repairs by insulation 12/17/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 5. Vent for kitchen sink missing, plans call for vent through the roof, highlighted on print ***Items 1, 2, and 3 are from previous inspection that have not been repaired*** 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ALL ROUGH 12/17/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 12/17/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required ***Items from previous inspection that have not been repaired*** 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ALL ROUGH 12/17/2025 Disapproved - NO FEE MKRASKI
Note: 12/17/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0, high lighted on print 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Annular space areound vent stack in spare bathroom (exterior wall) at roof decking exceeds allowable FBCR P2606.1 5. Vent for kitchen sink missing, plans call for vent through the roof, highlighted on print ***Items 1, 2, and 3 are from previous inspection that have not been repaired*** 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ELECTRIC-TUG 12/17/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 11:30am
LATH/BRICK/ WATER BARRIER 12/11/2025 APPROVED MKRASKI
ALL ROUGH 12/10/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 12/10/25 1. Garage door buck (over lintel) missing tap cons 16'' o.c. per detail MS11-S2.0 2. No E-cals on site FBC 107.3.1 3. Product approval sheet does not match garage entry door and front entry door a revision is required 4. Boots have not been installed FBCR P2606.1 5. 2 points of attachment are required for exhaust fans FBCR M1604.4.1 6. Pancake boxes on front of home have not been installed, need to verify bond NEC 314.4 7. Panel wiring must be properly phased NEC 210.5(C)(1) 8. Bushing required for SER cable connector at interior panel NEC 314.17(C) 9. Repair temp culvert to allow water to flow freely in swale FBC 3303.5 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0 Inspector Notes from Inspection 2460 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
LATH/BRICK/ WATER BARRIER 12/10/2025 Disapproved - NO FEE MKRASKI
Note: 12/10/25 holes on front of home from elec. need water barrier/lath 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ELECTRIC-TUG 12/10/2025 Disapproved - NO FEE MKRASKI
Note: Not ready, conduits not secured or glued wiring for temp outlet not installed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/04/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 12/4/25 The following 2 items must be completed by next inspection to avoid failure and fee 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 12/2/2025 - PREVIOUS INSPECTION NOTES 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
WALL SHEATHING 12/02/2025 APPROVED MKRASKI
Note:
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/02/2025 Disapproved - NO FEE MKRASKI
Note: 1. Truss engineering packet must have Building Dept. stamp of approval FBC 107.3.1 2. Missed wet set truss strap on T14 (right of SGD) 3. Gable end bracing not per detail GE01-D2 4. Garage door buck anchors not per detail MS12-S2.0 5. Over framing not strapped at entry and lani per detail 6. Lani truss to beam connection missing SDWC 15600 screws per "SC" S4.0
ROOF VALLEY & METAL 12/02/2025 APPROVED MKRASKI
ROOF SHEATHING 11/25/2025 APPROVED MKRASKI
Note:
WALL SHEATHING 11/25/2025 Disapproved - NO FEE MKRASKI
Note: 11/25/25 1. Repair silt fence to orginal condition FBC 3307.1 2. Wall sheathing not properly nailed off per plans Make repair by next inspection
GRAVITY SEWER TEST 11/20/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS APPROVED WITH FIRST ROUGH PLUMBING
SEWER TIE IN 11/20/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS APPROVED WITH FIRST ROUGH PLUMBING
TIE BEAM / LINTEL 11/18/2025 APPROVED - AS NOTED MKRASKI
Note: 11/18/25 1. Repair silt fence to orginal condition FBC 3307.1 Make repair by next inspection
TIE BEAM / LINTEL 11/17/2025 Disapproved - NO FEE MKRASKI
Note: 11/17/25 1. Repair silt fence to orginal condition FBC 3307.1 2. Dowl to close to face of block left side of garage door opening FBCR 606.3.4 3. Window sill bed joints exceed allowable check all FBCR 606.3.1
MONOLITHIC SLAB 11/10/2025 APPROVED MKRASKI
MONOLITHIC SLAB 11/07/2025 Disapproved - NO FEE MKRASKI
Note: 1. No intent to treat for termites paperwork onsite FBC [A] 105.11/FBCR 318 2. Several soft areas in slab (excavated areas) need to be recompacted FBCR 506.2.1
FORMBOARD SURVEY (OFFICE USE ONLY) 11/04/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 11/04/2025 APPROVED MGIBSON
Note: 11/3/2025 - PREVIOUS INSPECTION NOTES NO TE3ST ON ''DWV'' HEAD TEST NOT HOLDING, C/M TO SHEDUAL GRAVITY SEWER , AND SEWER TIE IN INSPECTION WHEN FIRST ROGH UNDER GROUND IS RE-SCHEDUALED
PLUMBING 1ST ROUGH UNDERGROUND 11/03/2025 Disapproved -FEE REQUIRED MGIBSON
Note: NO TE3ST ON ''DWV'' HEAD TEST NOT HOLDING, C/M TO SHEDUAL GRAVITY SEWER , AND SEWER TIE IN INSPECTION WHEN FIRST ROGH UNDER GROUND IS RE-SCHEDUALED
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 10/30/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 09/23/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 12/29/2025 12/30/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 11/04/2025 11/04/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 11/04/2025 11/04/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 10/29/2025 10/30/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 03/18/2025 03/21/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/18/2025 03/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 03/18/2025 03/18/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN COMPLETE 03/11/2025 03/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 03/11/2025 03/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/11/2025 03/12/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 03/11/2025 03/12/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/11/2025 03/11/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/11/2025 03/13/2025
LOCATE COMPLETE 03/11/2025 03/17/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/11/2025 03/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 03/11/2025 03/17/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Appears to be a typo on the right property line near the back (24.75'). Please revise.
ZON COMPLETE 03/11/2025 03/13/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 03/11/2025 03/18/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
REINSPECTION RESIDENTIAL ¤40.00 03/12/2026
CONNECTION FEES ¤1,187.26 09/02/2025
FC IMPACT FEE EMS ¤62.00 09/02/2025
IMPACT FEE FIRE ¤434.51 09/02/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/02/2025
FC IMPACT FEE LIBRARY ¤268.00 09/02/2025
IMPACT FEE PARKS ¤1,828.01 09/02/2025
IMPACT FEE SCHOOL ¤5,450.00 09/02/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 09/02/2025
WATER -IRRIGATION INSPECTION ¤25.00 09/02/2025
SURCHARGE FS 533.721 ¤9.36 09/02/2025
SURCHARGE - FS 468.631 ¤14.04 09/02/2025
SW ENG - FOUNDATION SURVEY ¤20.00 09/02/2025
SW ENG INSPECTION 80 ¤80.00 09/02/2025
SW ENG PRE APRON ¤30.00 09/02/2025
SW ENG - REVIEW 20 ¤20.00 09/02/2025
SW ENG RES REVIEW 200 ¤200.00 09/02/2025
SEWER INSPECTION ¤25.00 09/02/2025
SEWER CAPITAL FACILITY ¤6,120.52 09/02/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 09/02/2025
SITE PLAN 30 ¤30.00 09/02/2025
WATER- TURN ON ¤25.00 09/02/2025
ADJUSTMENT 10% (¤103.96) 09/02/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/02/2025
INSPECTION - RESIDENTIAL ¤786.50 09/02/2025
PLAN REVIEW - RESIDENTIAL ¤223.08 09/02/2025
Fees Total Due: ¤0.00 Total Paid: ¤23,369.46