Permit #2025030421
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00060-0240 |
| CONDITIONED SPACE: 1801 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| OPENED PORCH (WITH ROOF) : 58 sqft |
| Total Square Footage: 2281 sqft |
| Block: 00060 |
| Subdivision: 7028 - |
| Job Phone: 407-476-8195 |
| Location Address: 77 PHEASANT DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/07/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LLC |
|
Address 3670 MAGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address SUITE 220 ORLANDO, FL 32803 |
| Lot: 0240 |
| Contracted Stated Job Value: ¤175,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/11/2026 | FINAL APPROVED | MCONTRYMAN |
| Note: 11/19/25: NOTE: Engineer's letter for change of Engineer related to revised ledger board detail submitted on 11/13/25 is only Accepted at the time of this inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/06/2026 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/05/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 2/5/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 02/05/2026 | APPROVED | FSLADISH |
| Note: 2/5/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/05/2026 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 No CC, No IRR. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/03/2026 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/03/2026 | APPROVED | FSLADISH |
| Note: 2/3/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U-CROSS CONNECTION | 01/30/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, No IRR. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/09/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. Inspector Notes from Inspection 9470 10/31/25 SPOKE WITH BILL CM ON SITE AND HE IS IN THE PROCESS OF CLEANING THE TEMP PIPE. SILT FENCE IS RESET AROUND THE SITE AND SWALE IS OPEN AND CLEAR AT THE TIME OF THIS INSPECTION. I AM REMOVING PERMIT HOLD, IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN SITE THROUGHOUT THE CONSTRUCTION PROCESS. WILL MNITOR THE SITE FOR CONTINUED COMPLIANCE. _________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ 10/30/2025 - PREVIOUS INSPECTION NOTES 10-30-25 TPOLACEK*** TEMPORARY PIPE IS STILL 100% CLOGGED, SILT FENCE IS STILL FAILING AND NEEDS TO BE REESTABLISHED PERMIT IS PLACED ON HOLD AND INSPECTIONS ARE DAILY UNTIL CORRECTIONS HAVE BEEN COMPLETED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/27/2025 - PREVIOUS INSPECTION NOTES 10-27-25 TPOLACEK*** NO IMPROVMENTS HAVE BEEN MADE. THE STORM LAST NIGHT WASHED OUT MORE SEDIMENT INTO SWALE AND BACK CANAL. BUILDER HAS 3 DAYS TO MAKE IMPROVMENTS BEFORE PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2025 - PREVIOUS INSPECTION NOTES 10-23-25 TPOLACEK*** THE TEMPORARY PIPE IS 100% CLOGGED AND SWALE HAS BEEN WASHED OUT IMPEEDING THE FLOW OF THE DRAINAGE SYSTEM. SILT FENCE ALL AROUND NEEDS TO BE REESTABLISHED AND ANY SEDIMENT WASHED OFF SITE INTO COPC DITCH MUST BE REMOVED. NEXT INSPECTION MONDAY 10-27-25 WHERE IF CONDITIONS ARE NOT CORRECTED PERMIT WILL BE PLACED ON HOLD 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| ELECTRIC - EARLY POWER | 12/26/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: 12/26/25 Check pantry on final 2 gang cover/blank is missing *** NOTES ADDED BY RSIMS 11/10/2025 11:44:06 AM *** 11/10/25: FPL emailed approved for TUG. 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. RE-INSPECTION FEE APPLIED. 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25: 1). Bare copper ground needs to be run through a conduit from ground to the Meter Panel continuous. NEC 250.64(A)(2) | |||
| GRAVITY SEWER TEST | 12/22/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/22/2025 2:09:44 PM *** Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 9/25/2025 9:42:53 AM *** 9/25/25: Must be resolved before any additional inspections will be approved. 1). Silt fence needs to be fixed immedietly to protect neighboring properties along with canal in the back. FBC 3307.1 2). Portable toilet needs to be moved out of swale and onto site to allow free flow of water through the swale. FBC 3303.5 | |||
| SEWER TIE IN | 12/22/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/22/2025 2:09:21 PM *** Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 9/25/2025 9:42:53 AM *** 9/25/25: Must be resolved before any additional inspections will be approved. 1). Silt fence needs to be fixed immedietly to protect neighboring properties along with canal in the back. FBC 3307.1 2). Portable toilet needs to be moved out of swale and onto site to allow free flow of water through the swale. FBC 3303.5 | |||
| PEP TANK INSTALLATION REQUEST | 12/10/2025 | APPROVED | CBOWERMASTER |
| Note: 12/8/2025 7:56:01 AM- PREVIOUS INSPECTION NOTES dumpster needs to move | |||
| PEP TANK INSTALLATION REQUEST | 12/02/2025 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: dumpster needs to move | |||
| INSULATION | 11/25/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/25/2025 11:47:33 AM *** 11/21/2025 - PREVIOUS INSPECTION NOTES 11/21/25: PREVIOUSLY LISTED ITEM 1 REMAINS UNRESOLVED. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 11/19/2025 - PREVIOUS INSPECTION NOTES 11/19/25: Previously listed items below remain unresolved. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 c). Master Bathroom: piping for shower head supply (x 2 areas). Still missing the area above the shower valve. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: NOTE: Engineer's letter submitted on 11/13/25 that is only Accepted at the time of this inspection. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 a). Guest bathroom plumbing vent. b). Guest Bathroom: Ends of the fireblocking at top plate of bathtub pack out wall. c). Master Bathroom: piping for shower head supply (x 2 areas). d). Thermostat wires. FS written on studs below areas. 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0744. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| INSULATION | 11/21/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/21/2025 3:09:37 PM *** 11/21/25: PREVIOUSLY LISTED ITEM 1 REMAINS UNRESOLVED. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 11/19/2025 - PREVIOUS INSPECTION NOTES 11/19/25: Previously listed items below remain unresolved. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 c). Master Bathroom: piping for shower head supply (x 2 areas). Still missing the area above the shower valve. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: NOTE: Engineer's letter submitted on 11/13/25 that is only Accepted at the time of this inspection. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 a). Guest bathroom plumbing vent. b). Guest Bathroom: Ends of the fireblocking at top plate of bathtub pack out wall. c). Master Bathroom: piping for shower head supply (x 2 areas). d). Thermostat wires. FS written on studs below areas. 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0744. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| INSULATION | 11/19/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/19/2025 9:37:02 AM *** 11/19/25: Previously listed items below remain unresolved. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 c). Master Bathroom: piping for shower head supply (x 2 areas). Still missing the area above the shower valve. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: NOTE: Engineer's letter submitted on 11/13/25 that is only Accepted at the time of this inspection. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 a). Guest bathroom plumbing vent. b). Guest Bathroom: Ends of the fireblocking at top plate of bathtub pack out wall. c). Master Bathroom: piping for shower head supply (x 2 areas). d). Thermostat wires. FS written on studs below areas. 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0744. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| LATH/BRICK/ WATER BARRIER | 11/17/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/17/2025 8:58:46 AM *** | |||
| INSULATION | 11/14/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/14/2025 1:45:18 PM *** 11/14/25: NOTE: Engineer's letter submitted on 11/13/25 that is only Accepted at the time of this inspection. 1). Guest bathroom: Fireblocking at top plate of bathtub pack out wall needs to be 1-1/2" minimum or other approved material as required. FBC-R302.11.1. 2). Firestop missing where wires and/or piping penetrate into the attic space at the following locations: FBC-R302.11 a). Guest bathroom plumbing vent. b). Guest Bathroom: Ends of the fireblocking at top plate of bathtub pack out wall. c). Master Bathroom: piping for shower head supply (x 2 areas). d). Thermostat wires. FS written on studs below areas. 11/13/2025 - PREVIOUS INSPECTION NOTES 11/13/25: Cancelled by Applicant via text at @ 0744. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| INSULATION | 11/13/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/13/2025 9:13:03 AM *** 11/13/25: Cancelled by Applicant via text at @ 0744. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| ELECTRIC-TUG | 11/10/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/10/2025 11:44:06 AM *** 11/10/25: FPL emailed approved for TUG. 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. RE-INSPECTION FEE APPLIED. 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25: 1). Bare copper ground needs to be run through a conduit from ground to the Meter Panel continuous. NEC 250.64(A)(2) | |||
| ALL ROUGH | 11/10/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/10/2025 11:45:08 AM *** 11/10/25: Approved as noted to keep project moving. Previously listed items need to be resolved prior to any more inspections. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/07/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/7/2025 11:03:09 AM *** 11/7/25: Approved as noted to keep project moving. 1). Trusses (front) T20, T07 and T06 will require additional cleaning to remove foreign unknown substance along bottom cords and webs. 2). Garage ledger board is still missing solid blocking as required on plans. Highlighted. FBC [A]107.4 10/24/2025 - PREVIOUS INSPECTION NOTES 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| ELECTRIC-TUG | 11/03/2025 | Disapproved - NO FEE | RSIMS |
| Note: 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25: 1). Bare copper ground needs to be run through a conduit from ground to the Meter Panel continuous. NEC 250.64(A)(2) | |||
| ELECTRIC-TUG | 11/03/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/3/2025 1:43:07 PM *** 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. RE-INSPECTION FEE APPLIED. 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25: PREVIOUS DEFICIENCY REMAINS UNRESOVED. 10/30/2025 - PREVIOUS INSPECTION NOTES 10/30/25: 1). Bare copper ground needs to be run through a conduit from ground to the Meter Panel continuous. NEC 250.64(A)(2) | |||
| ROW - DRAINAGE | 10/31/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/31/25 SPOKE WITH BILL CM ON SITE AND HE IS IN THE PROCESS OF CLEANING THE TEMP PIPE. SILT FENCE IS RESET AROUND THE SITE AND SWALE IS OPEN AND CLEAR AT THE TIME OF THIS INSPECTION. I AM REMOVING PERMIT HOLD, IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN SITE THROUGHOUT THE CONSTRUCTION PROCESS. WILL MNITOR THE SITE FOR CONTINUED COMPLIANCE. _________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________ 10/30/2025 - PREVIOUS INSPECTION NOTES 10-30-25 TPOLACEK*** TEMPORARY PIPE IS STILL 100% CLOGGED, SILT FENCE IS STILL FAILING AND NEEDS TO BE REESTABLISHED PERMIT IS PLACED ON HOLD AND INSPECTIONS ARE DAILY UNTIL CORRECTIONS HAVE BEEN COMPLETED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/27/2025 - PREVIOUS INSPECTION NOTES 10-27-25 TPOLACEK*** NO IMPROVMENTS HAVE BEEN MADE. THE STORM LAST NIGHT WASHED OUT MORE SEDIMENT INTO SWALE AND BACK CANAL. BUILDER HAS 3 DAYS TO MAKE IMPROVMENTS BEFORE PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2025 - PREVIOUS INSPECTION NOTES 10-23-25 TPOLACEK*** THE TEMPORARY PIPE IS 100% CLOGGED AND SWALE HAS BEEN WASHED OUT IMPEEDING THE FLOW OF THE DRAINAGE SYSTEM. SILT FENCE ALL AROUND NEEDS TO BE REESTABLISHED AND ANY SEDIMENT WASHED OFF SITE INTO COPC DITCH MUST BE REMOVED. NEXT INSPECTION MONDAY 10-27-25 WHERE IF CONDITIONS ARE NOT CORRECTED PERMIT WILL BE PLACED ON HOLD 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| ROW - DRAINAGE | 10/30/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 10-30-25 TPOLACEK*** TEMPORARY PIPE IS STILL 100% CLOGGED, SILT FENCE IS STILL FAILING AND NEEDS TO BE REESTABLISHED PERMIT IS PLACED ON HOLD AND INSPECTIONS ARE DAILY UNTIL CORRECTIONS HAVE BEEN COMPLETED. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/27/2025 - PREVIOUS INSPECTION NOTES 10-27-25 TPOLACEK*** NO IMPROVMENTS HAVE BEEN MADE. THE STORM LAST NIGHT WASHED OUT MORE SEDIMENT INTO SWALE AND BACK CANAL. BUILDER HAS 3 DAYS TO MAKE IMPROVMENTS BEFORE PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2025 - PREVIOUS INSPECTION NOTES 10-23-25 TPOLACEK*** THE TEMPORARY PIPE IS 100% CLOGGED AND SWALE HAS BEEN WASHED OUT IMPEEDING THE FLOW OF THE DRAINAGE SYSTEM. SILT FENCE ALL AROUND NEEDS TO BE REESTABLISHED AND ANY SEDIMENT WASHED OFF SITE INTO COPC DITCH MUST BE REMOVED. NEXT INSPECTION MONDAY 10-27-25 WHERE IF CONDITIONS ARE NOT CORRECTED PERMIT WILL BE PLACED ON HOLD 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| ELECTRIC-TUG | 10/30/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/30/2025 10:35:17 AM *** 10/30/25: 1). Bare copper ground needs to be run through a conduit from ground to the Meter Panel continuous. NEC 250.64(A)(2) | |||
| ROOF VALLEY & METAL | 10/28/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/28/2025 9:37:43 AM *** | |||
| ROW - DRAINAGE | 10/27/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 10-27-25 TPOLACEK*** NO IMPROVMENTS HAVE BEEN MADE. THE STORM LAST NIGHT WASHED OUT MORE SEDIMENT INTO SWALE AND BACK CANAL. BUILDER HAS 3 DAYS TO MAKE IMPROVMENTS BEFORE PERMIT IS PLACED ON HOLD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2025 - PREVIOUS INSPECTION NOTES 10-23-25 TPOLACEK*** THE TEMPORARY PIPE IS 100% CLOGGED AND SWALE HAS BEEN WASHED OUT IMPEEDING THE FLOW OF THE DRAINAGE SYSTEM. SILT FENCE ALL AROUND NEEDS TO BE REESTABLISHED AND ANY SEDIMENT WASHED OFF SITE INTO COPC DITCH MUST BE REMOVED. NEXT INSPECTION MONDAY 10-27-25 WHERE IF CONDITIONS ARE NOT CORRECTED PERMIT WILL BE PLACED ON HOLD 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| WALL SHEATHING | 10/24/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/24/2025 12:24:42 PM *** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/24/2025 | PARTIALLY APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/24/2025 12:41:17 PM *** 10/24/25: Partial approval for Roof sheathing and down cell - Checked and approved: 1). Trusses need to be cleaned from dirt and unknown foreign substance due to improper delivery and staging as noted previously on 10/14/25 during inspection 2340 > NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. (a moisture test will be performed during re-inspection after cleaning is complete). 2). Ledger board is not attached as required on plans and is missing solid blocking also required on plans. Highlighted. FBC [A]107.4 3). 2-ply Truss T01 is not connected as required. Highlighted. FBC [A]107.4 4). Right side garage wall: bottom plate is not complete as required under Simpson DTT2Z tie-down as required by Manufacturer. FBC-R317.1 / FBC [A]107.4 | |||
| ROW - DRAINAGE | 10/23/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 10-23-25 TPOLACEK*** THE TEMPORARY PIPE IS 100% CLOGGED AND SWALE HAS BEEN WASHED OUT IMPEEDING THE FLOW OF THE DRAINAGE SYSTEM. SILT FENCE ALL AROUND NEEDS TO BE REESTABLISHED AND ANY SEDIMENT WASHED OFF SITE INTO COPC DITCH MUST BE REMOVED. NEXT INSPECTION MONDAY 10-27-25 WHERE IF CONDITIONS ARE NOT CORRECTED PERMIT WILL BE PLACED ON HOLD 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| ROW - DRAINAGE | 10/17/2025 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 10/17/25=THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. IT IS NECESSARY TO REMOVE THE PORTA POTTY FROM THE CITY ROAD AND PLACE IT ON YOUR PROPERTY. THE SILT FENCE ALONG THE DITCH LINE NEEDS ATTENTION. SILT FENCE IS NOT BURIED, LETTING WATER RUN UNDER THE SILT FENCE DIG 4" WIDE AND 4" DEEP TRENCH, BURRY BOTTON OF THE FABRIC Inspector be back on 10/23/25 Pictures attached | |||
| TIE BEAM / LINTEL | 10/15/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/15/2025 11:35:11 AM *** 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25: 1). Multiple Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. | |||
| TIE BEAM / LINTEL | 10/14/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/14/2025 1:15:44 PM *** 10/14/25: 1). Multiple Dowel / down rods do not meet the minimum clearance (2" from face of block and/or 3/4: from inside of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 NOTE: Trusses have been delivered and placed directly on soil. May require cleaning and/or Engineer's letter since they do not meet the Manufacturer's delivery and staging requirements. | |||
| MONOLITHIC SLAB | 10/01/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/1/2025 11:39:32 AM *** *** NOTES ADDED BY RSIMS 9/25/2025 9:42:53 AM *** 9/25/25: Must be resolved before any additional inspections will be approved. 1). Silt fence needs to be fixed immedietly to protect neighboring properties along with canal in the back. FBC 3307.1 2). Portable toilet needs to be moved out of swale and onto site to allow free flow of water through the swale. FBC 3303.5 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/25/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/25/2025 9:42:53 AM *** 9/25/25: Must be resolved before any additional inspections will be approved. 1). Silt fence needs to be fixed immedietly to protect neighboring properties along with canal in the back. FBC 3307.1 2). Portable toilet needs to be moved out of swale and onto site to allow free flow of water through the swale. FBC 3303.5 | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 09/24/2025 | APPROVED | AMOBLEY |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/24/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 08/29/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/13/2025 | 11/19/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/24/2025 | 09/24/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/24/2025 | 09/24/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/23/2025 | 09/24/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/12/2025 | 03/31/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/11/2025 | 03/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/11/2025 | 03/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/11/2025 | 03/12/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/11/2025 | 03/12/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/11/2025 | 03/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/11/2025 | 03/13/2025 |
| LOCATE | COMPLETE | 03/11/2025 | 03/17/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/11/2025 | 03/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/11/2025 | 03/18/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/11/2025 | 03/13/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/05/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 02/05/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 02/05/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 02/05/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 02/05/2026 |
| RSI REINSPECTION 2 | ¤75.00 | 02/05/2026 |
| UTILITY PEP REINSPECTION | ¤40.00 | 02/05/2026 |
| SEWER CREDIT | (¤650.00) | 08/07/2025 |
| SEWER INSPECTION | ¤25.00 | 08/07/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 08/07/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 08/07/2025 |
| SITE PLAN 30 | ¤30.00 | 08/07/2025 |
| WATER- TURN ON | ¤25.00 | 08/07/2025 |
| ADJUSTMENT 10% | (¤120.55) | 08/07/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/07/2025 |
| INSPECTION - RESIDENTIAL | ¤915.75 | 08/07/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤259.74 | 08/07/2025 |
| SURCHARGE FS 533.721 | ¤10.85 | 08/07/2025 |
| SURCHARGE - FS 468.631 | ¤16.28 | 08/07/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/07/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/07/2025 |
| SW ENG PRE APRON | ¤30.00 | 08/07/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/07/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/07/2025 |
| CONNECTION FEES | ¤1,187.26 | 08/07/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 08/07/2025 |
| IMPACT FEE FIRE | ¤434.51 | 08/07/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/07/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/07/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 08/07/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/07/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 08/07/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/07/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,127.51 |