Permit #2025030422

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00490-0190
CONDITIONED SPACE: 1654 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2162 sqft
Block: 00490
Subdivision: 7026 -
Job Phone: 407-476-8195
Location Address: 37 PIERCE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/07/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LLC

Address

3670 MAGUIRE BOULEVARD

ORLANDO, FL 32803

Address

SUITE 220

ORLANDO, FL 32803

Lot: 0190
Contracted Stated Job Value: ¤165,000.00
Job Description: single family residence
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/29/2026 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/29/2026 11:01:21 AM *** 1/27/2026 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1-NEC 408.4-LABEL ALL BREAKER IN PANEL Breaker #7 is mark Garage door and control wall outlets Breaker #18 have not mark and control garage door Please double check breakers make sure they mark as required
BLD - BUILDING FINAL 01/27/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 1/27/2026 10:48:28 AM *** #2-Please seal exterior wall , low voltage wire opening on wall by exterior maeter base #3-FBCR M1305.1.4.1-AC NEEDS 3' CLEARANCE FROM GROUND Please fix item before next inspection #1-NEC 408.4-LABEL ALL BREAKER IN PANEL Breaker #7 is mark Garage door and control wall outlets Breaker #18 have not mark and control garage door Please double check breakers make sure they mark as required
ROW - FINAL APRON (AFTER POUR) 01/21/2026 APPROVED FSLADISH
Note: 1/21/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 01/21/2026 APPROVED FSLADISH
Note: 1/21/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 01/21/2026 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No CC, No IRR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/20/2026 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 01/20/2026 APPROVED FSLADISH
Note: 1/20/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 01/20/2026 APPROVED - AS NOTED BHAINES
Note: No CC, No IRR.
DRYWALL NAILING 12/30/2025 CANCELLED BY INSPECTOR RSIMS
Note: *** NOTES ADDED BY RSIMS 12/30/2025 8:34:57 AM *** 12/29/25: This inspection was added in error as it was meant for a different location of a duplex. This inspection added for Fire Drywall nailing. Must be complete prior to finishing any drywall. If screws are used for installation of the 5/8" type X drywall throughout both units, the spacing much match the OC spacing for nails as required by UL requirements. Also, 5/8" type X drywall installed at exterior locations such as the lanai areas and front entry areas must be moisture rated & fire rated type.
ROW- PRE-APRON (PRE-POUR) 12/26/2025 APPROVED - AS NOTED TPOLACEK
Note: 12-26-25 TPOLACEK*** PLEASE MAKE SURE TO DIG OUT FOOTERS TO 6"X6" BEFORE POURING CONCRETE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
ELECTRIC - EARLY POWER 12/17/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/17/2025 1:29:52 PM *** 12/17/25: FPL emailed to release power. Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 11/3/2025 11:51:19 AM *** 11/3/25: FPL emailed approved for TUG.
GRAVITY SEWER TEST 12/04/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 fbc-3303.5 swale blocked
SEWER TIE IN 12/04/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 fbc-3303.5 swale blocked
PEP TANK INSTALLATION REQUEST 11/18/2025 APPROVED CBOWERMASTER
INSULATION 11/18/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/18/2025 9:27:29 AM *** Drywall Nailing Inspection added to permit to inspect anchoring of 5/8" type X drywall as required. *** NOTES ADDED BY RSIMS 11/18/2025 9:05:56 AM *** 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: Cancelled by Applicant via phone call at @ 1300. 11/12/2025 - PREVIOUS INSPECTION NOTES 11/12/25: PREVIOUSLY LISTED ITEMS 2 AND 4 REMAIN UNRESOLVED. PLEASE COMPLETE ALL ITEMS BEFORE SCHEDULING RE-INSPECTION. ALSO, CARDBOARD BAFFLES NEED TO BE RE-CHECKED. 11/7/2025 - PREVIOUS INSPECTION NOTES 11/7/25: Previously noted items 2, 3 and 4 remain unresolved. ALSO, SEE PREVIOUS NOTE PERTAINING TO CARDBOARD BAFFLES. 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 5). Numerous cardboard baffles do not have the 1" clearance required. FBC-R806.3 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/3/2025 12:03:14 PM *** 11/3/25: 1). No energy calcs or FPA document in permit box or on site. FBC [A]107.3.1 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
INSULATION 11/14/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 1:02:08 PM *** 11/14/25: Cancelled by Applicant via phone call at @ 1300. 11/12/2025 - PREVIOUS INSPECTION NOTES 11/12/25: PREVIOUSLY LISTED ITEMS 2 AND 4 REMAIN UNRESOLVED. PLEASE COMPLETE ALL ITEMS BEFORE SCHEDULING RE-INSPECTION. ALSO, CARDBOARD BAFFLES NEED TO BE RE-CHECKED. 11/7/2025 - PREVIOUS INSPECTION NOTES 11/7/25: Previously noted items 2, 3 and 4 remain unresolved. ALSO, SEE PREVIOUS NOTE PERTAINING TO CARDBOARD BAFFLES. 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 5). Numerous cardboard baffles do not have the 1" clearance required. FBC-R806.3 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/3/2025 12:03:14 PM *** 11/3/25: 1). No energy calcs or FPA document in permit box or on site. FBC [A]107.3.1 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
LATH/BRICK/ WATER BARRIER 11/13/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/13/2025 2:08:13 PM *** 11/12/2025 - PREVIOUS INSPECTION NOTES 11/12/25: 1). Left side of the house has holes in CMU that require lath. FBC [A]107.4
INSULATION 11/12/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/12/2025 1:43:22 PM *** 11/12/25: PREVIOUSLY LISTED ITEMS 2 AND 4 REMAIN UNRESOLVED. PLEASE COMPLETE ALL ITEMS BEFORE SCHEDULING RE-INSPECTION. ALSO, CARDBOARD BAFFLES NEED TO BE RE-CHECKED. 11/7/2025 - PREVIOUS INSPECTION NOTES 11/7/25: Previously noted items 2, 3 and 4 remain unresolved. ALSO, SEE PREVIOUS NOTE PERTAINING TO CARDBOARD BAFFLES. 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 5). Numerous cardboard baffles do not have the 1" clearance required. FBC-R806.3 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/3/2025 12:03:14 PM *** 11/3/25: 1). No energy calcs or FPA document in permit box or on site. FBC [A]107.3.1 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
LATH/BRICK/ WATER BARRIER 11/12/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/12/2025 1:44:17 PM *** 11/12/25: 1). Left side of the house has holes in CMU that require lath. FBC [A]107.4
INSULATION 11/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/7/2025 11:49:36 AM *** 11/7/25: Previously noted items 2, 3 and 4 remain unresolved. ALSO, SEE PREVIOUS NOTE PERTAINING TO CARDBOARD BAFFLES. 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 5). Numerous cardboard baffles do not have the 1" clearance required. FBC-R806.3 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 11/3/2025 12:03:14 PM *** 11/3/25: 1). No energy calcs or FPA document in permit box or on site. FBC [A]107.3.1 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
ALL ROUGH 11/03/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/3/2025 12:03:14 PM *** 11/3/25: 1). No energy calcs or FPA document in permit box or on site. FBC [A]107.3.1 2). Bathroom exhaust fans are missing the 2nd (mechanical) point of contact. (plastic strap or hose clamp). as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 3). No 5ft. head pressure. FBC-P2503.5.1 4). Master bathroom exhaust fan pipe needs to be sealed fully at the roof deck. FBCR M1601.4.1 *** NOTE: CARDBOARD BAFFLES INSTALLED PRIOR TO THIS INSPECTION > NEED TO HAVE 1" CLEARANCE FROM ROOF DECK AS REQUIRED. FBC-R806.3 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
ELECTRIC-TUG 11/03/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/3/2025 11:51:19 AM *** 11/3/25: FPL emailed approved for TUG.
ROOF VALLEY & METAL 10/22/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/22/2025 11:32:39 AM *** 10/22/25: Silt fence still needs to be repaired but now in multiple areas. This will need to be complete prior to any further inspection approvals. Inspector Notes from Inspection 2460 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
WALL SHEATHING 10/21/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/21/2025 10:06:22 AM ***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/21/2025 APPROVED - AS NOTED RSIMS
Note: 10/21/25: 1). Please have silt fence on the Pierce lane side repaired and keep it maintained. 'FBC 3307.1
TIE BEAM / LINTEL 10/09/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/1/2025 12:49:15 PM *** At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and in accordance with FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
MONOLITHIC SLAB 10/01/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/1/2025 12:49:15 PM *** At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and in accordance with FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
FORMBOARD SURVEY (OFFICE USE ONLY) 09/24/2025 APPROVED AMOBLEY
PLUMBING 1ST ROUGH UNDERGROUND 09/22/2025 APPROVED - AS NOTED MGIBSON
Note: fbc-3303.5 swale blocked
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/09/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 08/21/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/24/2025 09/24/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 09/24/2025 09/24/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/09/2025 09/09/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/20/2025 03/20/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
SWALE COMPLETE 03/12/2025 03/31/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 03/11/2025 03/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 03/11/2025 03/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/11/2025 03/12/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 03/11/2025 03/12/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/11/2025 03/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/11/2025 03/13/2025
LOCATE COMPLETE 03/11/2025 03/17/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/11/2025 03/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 03/11/2025 03/18/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Missing proposed elevation on front right property line. This elevation should be equal to or higher than EP.
ZON COMPLETE 03/11/2025 03/13/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 01/28/2026
REINSPECTION RESIDENTIAL ¤40.00 01/19/2026
REINSPECTION RESIDENTIAL ¤40.00 01/19/2026
WATER- TURN ON ¤25.00 08/07/2025
ADJUSTMENT 10% (¤112.43) 08/07/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/07/2025
INSPECTION - RESIDENTIAL ¤852.50 08/07/2025
PLAN REVIEW - RESIDENTIAL ¤241.80 08/07/2025
CONNECTION FEES ¤1,187.26 08/07/2025
FC IMPACT FEE EMS ¤62.00 08/07/2025
IMPACT FEE FIRE ¤434.51 08/07/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/07/2025
FC IMPACT FEE LIBRARY ¤268.00 08/07/2025
IMPACT FEE PARKS ¤1,828.01 08/07/2025
IMPACT FEE SCHOOL ¤5,450.00 08/07/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 08/07/2025
WATER -IRRIGATION INSPECTION ¤25.00 08/07/2025
SURCHARGE FS 533.721 ¤10.12 08/07/2025
SURCHARGE - FS 468.631 ¤15.18 08/07/2025
SW ENG - FOUNDATION SURVEY ¤20.00 08/07/2025
SW ENG INSPECTION 80 ¤80.00 08/07/2025
SW ENG PRE APRON ¤30.00 08/07/2025
SW ENG - REVIEW 20 ¤20.00 08/07/2025
SW ENG RES REVIEW 200 ¤200.00 08/07/2025
SEWER CREDIT (¤2,465.75) 08/07/2025
SEWER INSPECTION ¤25.00 08/07/2025
SEWER CAPITAL FACILITY ¤6,120.52 08/07/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 08/07/2025
SITE PLAN 30 ¤30.00 08/07/2025
Fees Total Due: ¤0.00 Total Paid: ¤20,981.86