I want to search for...
Permit #2025030437
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00570-0330 |
| CONDITIONED SPACE: 2870 sqft |
| GARAGE: 894 sqft |
| SCREEN PORCH (SOLID ROOF) : 192 sqft |
| OPENED PORCH (WITH ROOF) : 154 sqft |
| Total Square Footage: 4110 sqft |
| Block: 00570 |
| Subdivision: 7027 - |
| Job Phone: 530-308-7323 |
| Location Address: 12 WOOD ACRE LN |
| Type: DU - DUPLEX |
| Issue Date: 03/28/2025 |
| NOC: RECORDED |
| Applicant name: DONALD CABRAL |
| Owner: ENDURANCE PROPERTY HOLDING LLC |
|
Address PO BOX 121 EAST SCHODACK, NY 12063 |
| Lot: 0330 |
| Contracted Stated Job Value: ¤500,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
DC CONSTRUCTION PALM COAST LLC
| Status | Location Address | State License Number |
| ACTIVE |
109 UNIVERSAL TRAIL , |
CGC1531039 (Exp: 08/31/2026) |
Sub Contractors
SCOTT R WOODARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
51 PINEAPPLE DRIVE PALM COAST, FL 32164 |
ES12000383 (Exp: 08/31/2026) | 386-264-4964 |
ROBERT EDWIN BERRONG
| Status | Location Address | State License Number | Phone |
| ACTIVE |
800 BELLE TERRE PKWY STE 200-114 FLAGLER BEACH, FL 32136 |
CCC1336183 (Exp: 08/31/2026) | 386-266-9879 |
DENNIS BRAXTON BRAGG
| Status | Location Address | State License Number | Phone |
| ACTIVE |
363 FIR STREET ORMOND BEACH, FL 32174 |
CFC1433357 (Exp: 08/31/2026) | 386-882-7971 |
JUAN EUGENIO CAMPELO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
114 ALLGOOD CIRCLE SUITE #101 ST AUGUSTINE, FL 32086 |
CAC1813797 (Exp: 08/31/2026) | 904-824-4275 | 904-824-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 11/26/2025 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 8/15/2025 - PREVIOUS INSPECTION NOTES see note on #6 IRR WITH POTABLE WATER METER. | |||
| ROW - FINAL INSPECTION | 11/25/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 11/25/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/25/2025 | APPROVED | TPOLACEK |
| Note: 11/13/2025 - PREVIOUS INSPECTION NOTES 11-13-25 TPOLACEK*** MET WITH CM ON SITE TO DISCUSS THE LEFT SIDE DRAIANGE ALONG PROPERTY. BUILDER NEEDS TO CREATE AN INSIDE "W" SWALE OF .30 DEEP MINIMUM FROM LEFT REAR OF STRUCTURE OUT PAST THE END OF THE FENCE. Finished Floor Elevations (FFE): Section 300.01 C(9) V-16 9)Backfilling against existing fencing on an adjacent or rear property is not permitted. Section 300.01 C(9) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 11/10/2025 - PREVIOUS INSPECTION NOTES 11-10-25 TPOLACEK*** FINAL SURVEY IS MISSING SHOTS ACROSS THE BACK (SEE PHOTO WHERE STARS ARE NEEDS SHOTS) LEFT SIDE DOES NOT HAVE POSITIVE FLOW AND WILL HOLD WATER. 11/3/2025 - PREVIOUS INSPECTION NOTES 11-03-25 TPOLACEK*** FINAL SUREVY INDICATES PROPERTY TO THE RIGHT IS A VACANT. THIS IS AN IMPROVED LOT AND REQUIRES FFE Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 "Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. " | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/25/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/13/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-13-25 TPOLACEK*** MET WITH CM ON SITE TO DISCUSS THE LEFT SIDE DRAIANGE ALONG PROPERTY. BUILDER NEEDS TO CREATE AN INSIDE "W" SWALE OF .30 DEEP MINIMUM FROM LEFT REAR OF STRUCTURE OUT PAST THE END OF THE FENCE. Finished Floor Elevations (FFE): Section 300.01 C(9) V-16 9)Backfilling against existing fencing on an adjacent or rear property is not permitted. Section 300.01 C(9) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 11/10/2025 - PREVIOUS INSPECTION NOTES 11-10-25 TPOLACEK*** FINAL SURVEY IS MISSING SHOTS ACROSS THE BACK (SEE PHOTO WHERE STARS ARE NEEDS SHOTS) LEFT SIDE DOES NOT HAVE POSITIVE FLOW AND WILL HOLD WATER. 11/3/2025 - PREVIOUS INSPECTION NOTES 11-03-25 TPOLACEK*** FINAL SUREVY INDICATES PROPERTY TO THE RIGHT IS A VACANT. THIS IS AN IMPROVED LOT AND REQUIRES FFE Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 "Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. " | |||
| BLD - BUILDING FINAL | 11/13/2025 | FINAL APPROVED | MKRASKI |
| BLD - BUILDING FINAL | 11/10/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 11/10/25 Items 2, 6, 7, and 11 Make all repairs before re-inspection 11/3/25 1. Clean up all trash 2. E-cals do not match equipment installed 3. Meter mains need to be labeled with which unit they feed 4. Label all breakers in meter main 5. ODU breaker is over sized 6. AHU heater sticker not marked 7. 20a circuit required for garage outlets NEC 210.11(C) 8. Dryer vent screen needs to be removed 9. Termite sticker missing on elec. panel 10. SPD breaker is oversized per manufacturer spec 11. Locking caps required for ODU 12. Garage door buck anchor spacing is 14'' o.c. per plans, missing anchors | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/10/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-10-25 TPOLACEK*** FINAL SURVEY IS MISSING SHOTS ACROSS THE BACK (SEE PHOTO WHERE STARS ARE NEEDS SHOTS) LEFT SIDE DOES NOT HAVE POSITIVE FLOW AND WILL HOLD WATER. 11/3/2025 - PREVIOUS INSPECTION NOTES 11-03-25 TPOLACEK*** FINAL SUREVY INDICATES PROPERTY TO THE RIGHT IS A VACANT. THIS IS AN IMPROVED LOT AND REQUIRES FFE Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 "Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. " | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/03/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 11-03-25 TPOLACEK*** FINAL SUREVY INDICATES PROPERTY TO THE RIGHT IS A VACANT. THIS IS AN IMPROVED LOT AND REQUIRES FFE Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 "Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent lots. " | |||
| BLD - BUILDING FINAL | 11/03/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Clean up all trash 2. E-cals do not match equipment installed 3. Meter mains need to be labeled with which unit they feed 4. Label all breakers in meter main 5. ODU breaker is over sized 6. AHU heater sticker not marked 7. 20a circuit required for garage outlets NEC 210.11(C) 8. Dryer vent screen needs to be removed 9. Termite sticker missing on elec. panel 10. SPD breaker is oversized per manufacturer spec 11. Locking caps required for ODU 12. Garage door buck anchor spacing is 14'' o.c. per plans, missing anchors | |||
| U-CROSS CONNECTION | 11/03/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: 8/15/2025 - PREVIOUS INSPECTION NOTES see note on #6 IRR WITH POTABLE WATER METER. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/04/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ROW - DRAINAGE | 09/02/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 8/25/2025 - PREVIOUS INSPECTION NOTES 08/25/25/ TPOLACEK*** BUILDER IS GOING TO BE FORMING DRIVEWAY AND FINAL GRADE THIS WEEK. I WILL GIVE BUILDER AN ADDITIONAL WEEK TO GET GRADING DONE. BUILDER TO INSTALL SILT FENCE ALONG IMPROVED LOT TO THE LEFT. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/18/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ELECTRIC - EARLY POWER | 08/26/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 12:30pm | |||
| ELECTRIC - EARLY POWER | 08/25/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 8/25/25 Cancelled via text from super 7/2/25 Via phone call from super | |||
| ROW - DRAINAGE | 08/25/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 08/25/25/ TPOLACEK*** BUILDER IS GOING TO BE FORMING DRIVEWAY AND FINAL GRADE THIS WEEK. I WILL GIVE BUILDER AN ADDITIONAL WEEK TO GET GRADING DONE. BUILDER TO INSTALL SILT FENCE ALONG IMPROVED LOT TO THE LEFT. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/18/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| ROW - DRAINAGE | 08/18/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. | |||
| U-CROSS CONNECTION | 08/15/2025 | CANCELLED BY APPLICANT | LFITZGERALD |
| Note: see note on #6 | |||
| GRAVITY SEWER TEST | 08/05/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 ALL PIPES PASSING THROUGH FOUNDATION WALLS SHALL HAVE A RELIEVING ARCH OR A SLEEVE 2 PIPE SIZES GREATERTHAN PIPE PASSING THROUGH | |||
| SEWER TIE IN | 08/05/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 ALL PIPES PASSING THROUGH FOUNDATION WALLS SHALL HAVE A RELIEVING ARCH OR A SLEEVE 2 PIPE SIZES GREATERTHAN PIPE PASSING THROUGH | |||
| LATH/BRICK/ WATER BARRIER | 08/05/2025 | APPROVED | MKRASKI |
| FIREWALL FINAL | 07/29/2025 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 07/23/2025 | PARTIALLY APPROVED | MKRASKI |
| Note: Partially approved call back in once ready for where brick will be located on front | |||
| LATH/BRICK/ WATER BARRIER | 07/22/2025 | CANCELLED BY APPLICANT | MKRASKI |
| INSULATION | 07/21/2025 | APPROVED | MKRASKI |
| ALL ROUGH | 07/18/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Smokes must be a min of 3' away from all fan blades 2. Front door gaps exceed 1/4'' 3. Register missing seals 4. Wiring in panel needs proper phasing 5. Duct layout does not match what was installed Make all repairs before insulation | |||
| FIREWALL FRAMING | 07/16/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Kitchen bump out and draft stop approved, minus penitrations for SER | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/16/2025 | APPROVED | MKRASKI |
| Note: 6/30/2025 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC - EARLY POWER | 07/02/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Via phone call from super | |||
| ROOF VALLEY & METAL | 06/30/2025 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/30/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Front entry pony wall not per detail FBC (A)107.4 2. Ferring strips are not cont. from top to bottom for fire blocking FBC-302.11/FBC 302.11.1 3. Over framing missing L50s per detail FBC (A)107.4 4. 2x4 kitchen wall is installed over ferring strips, must be framed to cmu wall 5. Off ridge vents have not been framed per plans FBC (A)107.4 6. Clean all truss's off of debris per MiTek packet FBC (A)107.4 7 Gable bracing not per detail FBC (A)107.4 | |||
| FIREWALL FRAMING | 06/30/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. 2x4 kitchen wall is installed over ferring strips, must be framed to cmu wall | |||
| FIREWALL DRYWALL NAILING | 06/30/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Draft stop approved | |||
| WALL SHEATHING | 06/20/2025 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Please have a clean bound together set of plans for inspector per FBC 107.3.1 2. Address must be visible from road with 4'' number 1/2'' wide per FBC 319.1 Call back in for full re-inspection when both repairs are made | |||
| FIREWALL DRYWALL NAILING | 06/20/2025 | CANCELLED BY APPLICANT | WEB |
| FIREWALL DRYWALL NAILING | 06/20/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Draft stop must extend all the way out to the to of where soffit will be per plans FBC (A)107.4 2. Address must be visible from road with 4'' number 1/2'' wide per FBC 319.1 | |||
| FIREWALL FRAMING | 06/20/2025 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 05/20/2025 | APPROVED | MCONTRYMAN |
| MONOLITHIC SLAB | 05/08/2025 | APPROVED | MCONTRYMAN |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: ALL PIPES PASSING THROUGH FOUNDATION WALLS SHALL HAVE A RELIEVING ARCH OR A SLEEVE 2 PIPE SIZES GREATERTHAN PIPE PASSING THROUGH | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/30/2025 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/22/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 04/11/2025 | APPROVED | CBOWERMASTER |
| WATER METER INSTALLATION REQUEST | 04/02/2025 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 11/24/2025 | 11/24/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME FILE NAME TO FINAL SURVEY.PDF | |||
| MECH | COMPLETE | 11/07/2025 | 11/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/04/2025 | 08/04/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/30/2025 | 07/30/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Mechanical subcontractor certification is inactive. Please correct | |||
| MECH | COMPLETE | 07/16/2025 | 07/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/02/2025 | 07/09/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/30/2025 | 04/30/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/30/2025 | 04/30/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/22/2025 | 04/22/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 03/31/2025 | 03/31/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM NOC is to be recorded with the Flagler County Clerk of Courts and a copy then provided to the building department. | |||
| BADMIN | COMPLETE | 03/28/2025 | 03/28/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/24/2025 | 03/26/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/24/2025 | 03/26/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/24/2025 | 03/24/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 03/24/2025 | 03/28/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Lien law missing. 2nd request | |||
| BLD | COMPLETE | 03/24/2025 | 03/28/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/24/2025 | 03/24/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/24/2025 | 03/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/12/2025 | 03/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 03/11/2025 | 03/17/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Geotech report not digitally verifiable. | |||
| BLD | HOLD | 03/11/2025 | 03/17/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Plans need soil bearing pressure note. 2. Plans need code criteria. | |||
| CUSVC | COMPLETE | 03/11/2025 | 03/12/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/11/2025 | 03/12/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and Dryer need to be GFCI protected. NEC 2020 210.8 2. Need correct outlet spacing in bed 2 NEC 2020 210.52 | |||
| ENGIN1 | HOLD | 03/11/2025 | 03/12/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Proposed FFE is more than 10" different with its adjacent neighbor. | |||
| GAS | CANCEL | 03/11/2025 | 03/13/2025 |
| LOCATE | COMPLETE | 03/11/2025 | 03/17/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/11/2025 | 03/13/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to be daytona Beach 2. Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition 3. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition | |||
| SW1 | HOLD | 03/11/2025 | 03/18/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM FFE is more than 10" of adjacent lot. | |||
| ZON | HOLD | 03/11/2025 | 03/13/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM COLOR SHEET: CAY COLOR is not considered a pastel color. Pastel needs to meet the requirement of 80 % or higher. FLOOR PLAN: is missing please provide. There for the review has not been completed | |||
| BADMIN | HOLD | 03/11/2025 | 03/11/2025 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Lien law missing. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 11/24/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/07/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 09/14/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 09/14/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 09/14/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/28/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/28/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/28/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/28/2025 |
| SEWER CREDIT | (¤2,016.00) | 03/28/2025 |
| SEWER INSPECTION | ¤25.00 | 03/28/2025 |
| SEWER CAPITAL FACILITY | ¤12,241.04 | 03/28/2025 |
| WATER CAPITAL FACILITY FEE | ¤8,702.28 | 03/28/2025 |
| SITE PLAN 30 | ¤30.00 | 03/28/2025 |
| CONNECTION FEES | ¤2,374.52 | 03/28/2025 |
| FC IMPACT FEE EMS | ¤124.00 | 03/28/2025 |
| IMPACT FEE FIRE | ¤869.02 | 03/28/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 03/28/2025 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 03/28/2025 |
| IMPACT FEE PARKS | ¤3,656.02 | 03/28/2025 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 03/28/2025 |
| IMPACT FEE TRANSPORTATION | ¤2,974.00 | 03/28/2025 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 03/28/2025 |
| SURCHARGE FS 533.721 | ¤18.09 | 03/28/2025 |
| SURCHARGE - FS 468.631 | ¤27.14 | 03/28/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/28/2025 |
| WATER- TURN ON | ¤50.00 | 03/28/2025 |
| ADJUSTMENT 10% | (¤201.03) | 03/28/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/28/2025 |
| INSPECTION - RESIDENTIAL | ¤1,542.75 | 03/28/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤437.58 | 03/28/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤43,288.91 |