I want to search for...

Permit #2025030601

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00470-0150
CONDITIONED SPACE: 1809 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 2248 sqft
Block: 00470
Subdivision: -
Job Phone: 239-571-5325
Location Address: 45 PORT ROYAL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/21/2025
NOC: RECORDED
Applicant name: RYAN SCOTT DAVIS
Owner: SYNERGY HOMES, LLC

Address

581 NW MERCANTILE PLACE, 106

PORT SAINT LUCIE, FL 34986

Lot: 0150
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SYNERGY HOMES, LLC
Status Location Address State License Number
ACTIVE

1 HARGROVE GRADE, SUITE B1

PALM COAST, FL 32137

CBC1254289 (Exp: 08/31/2026)

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 07/08/2025 APPROVED TPOLACEK
Note: 07/08/25 TPOLACEK*** WHEN COPC MAKES CONNECTION FOR BUILDER IT IS THE BUILDERS RESPONSIBILTY TO REPAIR THE DAMAGE FOR THE CONNCTION MADE FOR THEIR BUILD. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9272 7/7/25 I HAVE PASSED THIS INSPECTION AS NOTED IN PLACE OF THE ROW FINAL YOU SUBMITTED FOR AS YOU WILL NEED ROW REPAIR AND RESODDING TO GRADE ON THR LEFT SIDE FRONT SWALE AND ALSO ACROSS THE STREET.
U -UTILITY RESIDENTIAL FINAL 07/07/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 No IRR. No cc
ROW - FINAL APRON (AFTER POUR) 07/07/2025 APPROVED - AS NOTED FSLADISH
Note: 7/7/25 I HAVE PASSED THIS INSPECTION AS NOTED IN PLACE OF THE ROW FINAL YOU SUBMITTED FOR AS YOU WILL NEED ROW REPAIR AND RESODDING TO GRADE ON THR LEFT SIDE FRONT SWALE AND ALSO ACROSS THE STREET.
ROW - STORMWATER FINAL 07/07/2025 Disapproved - NO FEE FSLADISH
Note: 7/7/25 INSPECTORS NOTE. I AM DISAPPROVING THIS INSPECTION WITH NO FEE AND I WILL APPROVE YOUR FINAL APRON IN IT'S PLACE AS I WILL NOT PASS ROW FINAL TILL REPAIR AND RESOD IS DONE ON LEFT SIDE FRONT SWALE AND ACROSS THE STREET AS REQUIRED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/03/2025 APPROVED TPOLACEK
Note: 7/2/2025 - PREVIOUS INSPECTION NOTES 07/02/25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO HAVE ALL 4 CORNER SHOTS AS WELL AS SHOTYS ALONG THE STRUCTURE. The Initial Application for Building Permit shall be accompanied by: Section 200.01.1.b(5) (5) Elevations at the lot corners, at foundation corners, along all sides of the proposed building, and 10 feet off the proposed building are required in addition to the 20-foot grid.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/03/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/02/2025 Disapproved - NO FEE TPOLACEK
Note: 07/02/25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO HAVE ALL 4 CORNER SHOTS AS WELL AS SHOTYS ALONG THE STRUCTURE. The Initial Application for Building Permit shall be accompanied by: Section 200.01.1.b(5) (5) Elevations at the lot corners, at foundation corners, along all sides of the proposed building, and 10 feet off the proposed building are required in addition to the 20-foot grid.
BLD - BUILDING FINAL 07/02/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/2/2025 3:07:20 PM *** 7/1/2025 - PREVIOUS INSPECTION NOTES 7/1/25: 1). SD/CO detectors outside of Laundry and at Vaulted ceiling are not interconnected with others as required. FBC-R314.4 2). Missing Insulation certificate on site. (posted in attic). FBC EC R303.1.1.2 3). Dishwasher is not plugged in. Could not test/inspect. FBC-[A] 110.1 (plug is barely into cabinet. need to confirm length also). NOTE: found Energy calcs in kitchen drawer. 6/27/2025 - PREVIOUS INSPECTION NOTES 6/27/25: Cancelled by Applicant via phone call at @ 09:15.
BLD - BUILDING FINAL 07/01/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/1/2025 12:42:23 PM *** 7/1/25: 1). SD/CO detectors outside of Laundry and at Vaulted ceiling are not interconnected with others as required. FBC-R314.4 2). Missing Insulation certificate on site. (posted in attic). FBC EC R303.1.1.2 3). Dishwasher is not plugged in. Could not test/inspect. FBC-[A] 110.1 (plug is barely into cabinet. need to confirm length also). NOTE: found Energy calcs in kitchen drawer. 6/27/2025 - PREVIOUS INSPECTION NOTES 6/27/25: Cancelled by Applicant via phone call at @ 09:15.
BLD - BUILDING FINAL 06/27/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 6/27/2025 9:19:03 AM *** 6/27/25: Cancelled by Applicant via phone call at @ 09:15.
GRAVITY SEWER TEST 06/24/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 FBC-3303.5 SWALE BLOCKED BY PORTABLE
SEWER TIE IN 06/24/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 FBC-3303.5 SWALE BLOCKED BY PORTABLE
ELECTRIC - EARLY POWER 06/17/2025 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 06/17/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/17/2025 12:36:25 PM *** 6/17/25: FPL emailed to release power. NOTE: Portable toilet needs to be immedietely moved out of the swale area of the wooded lot across the street. Thank you. FBC 3303.5
PEP TANK INSTALLATION REQUEST 06/09/2025 APPROVED CBOWERMASTER
INSULATION 06/03/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/3/2025 3:29:15 PM *** 6/2/2025 - PREVIOUS INSPECTION NOTES 6/2/25: Cancelled by Applicant via phone call at @ 09:15.
ROW- PRE-APRON (PRE-POUR) 06/03/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
INSULATION 06/02/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 6/2/2025 9:19:09 AM *** 6/2/25: Cancelled by Applicant via phone call at @ 09:15.
LATH/BRICK/ WATER BARRIER 05/30/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 05/30/2025 APPROVED CVANSTRAHLEN
Note:
ALL ROUGH 05/23/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Not ready , electrician still working
U-CROSS CONNECTION 05/21/2025 APPROVED - AS NOTED BWRIGHT
Note: No IRR. No cc
WALL SHEATHING 05/19/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2340 5/6/2025 - PREVIOUS INSPECTION NOTES Please have dumpter and removed work and trash debris front work side by next inspection 3). Please have a dumpster on site and have the pile of loose trash and debris cleaned up. FBC 3302.2 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/19/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2340 5/6/2025 - PREVIOUS INSPECTION NOTES Please have dumpter and removed work and trash debris front work side by next inspection 3). Please have a dumpster on site and have the pile of loose trash and debris cleaned up. FBC 3302.2 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
ROOF VALLEY & METAL 05/19/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2340 5/6/2025 - PREVIOUS INSPECTION NOTES Please have dumpter and removed work and trash debris front work side by next inspection 3). Please have a dumpster on site and have the pile of loose trash and debris cleaned up. FBC 3302.2 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
TIE BEAM / LINTEL 05/07/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: 5/6/2025 - PREVIOUS INSPECTION NOTES Please have dumpter and removed work and trash debris front work side by next inspection 3). Please have a dumpster on site and have the pile of loose trash and debris cleaned up. FBC 3302.2 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
TIE BEAM / LINTEL 05/06/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/6/2025 1:46:49 PM *** 5/6/25: 1). Dowel rods do not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange. 2). Portable toilet needs to be removed from neighboring vacant lot swale area and onto site property where it will need to remain for the duration of the project. FBC 3303.5 3). Please have a dumpster on site and have the pile of loose trash and debris cleaned up. FBC 3302.2 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
MONOLITHIC SLAB 04/28/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/28/2025 11:36:19 AM *** 4/28/25: 1). Please move portable toilet from swale area to allow free flow of water. FBC 3303.5
MONOLITHIC SLAB 04/25/2025 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 04/22/2025 APPROVED - AS NOTED MGIBSON
Note: FBC-3303.5 SWALE BLOCKED BY PORTABLE
FORMBOARD SURVEY (OFFICE USE ONLY) 04/22/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/21/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 04/07/2025 APPROVED CBOWERMASTER
WILDLIFE CHECK - ENVIRONMENTAL 03/19/2025 APPROVED DRODRIGUEZ

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 04/22/2025 04/22/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/22/2025 04/22/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 04/16/2025 04/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLENV COMPLETE 03/19/2025 03/19/2025
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 03/19/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
PLENV COMPLETE 03/18/2025 03/19/2025
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 03/19/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. Attached letter from the QEP meets city requirements for compliance With 10.04.01 of the LDC. If any Gopher Tortoises or their burrows are found in the future, further coordination may be needed.
BADMIN COMPLETE 03/14/2025 03/19/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 03/14/2025 03/19/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/14/2025 03/18/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 03/14/2025 03/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/14/2025 03/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/14/2025 03/19/2025
LOCATE COMPLETE 03/14/2025 03/19/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/14/2025 03/19/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/14/2025 03/20/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Final PEP location to be provided by COPC. The stormwater conveyance swales associated with the lot’s grading shall be diverted around the PEP lid/cover.
ZON COMPLETE 03/14/2025 03/18/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 03/14/2025 04/01/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 07/07/2025
CONNECTION FEES ¤1,187.26 03/21/2025
FC IMPACT FEE EMS ¤62.00 03/21/2025
IMPACT FEE FIRE ¤434.51 03/21/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/21/2025
FC IMPACT FEE LIBRARY ¤268.00 03/21/2025
IMPACT FEE PARKS ¤1,828.01 03/21/2025
IMPACT FEE SCHOOL ¤5,450.00 03/21/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 03/21/2025
WATER -IRRIGATION INSPECTION ¤25.00 03/21/2025
SURCHARGE FS 533.721 ¤10.82 03/21/2025
SURCHARGE - FS 468.631 ¤16.23 03/21/2025
SW ENG - FOUNDATION SURVEY ¤20.00 03/21/2025
SW ENG INSPECTION 80 ¤80.00 03/21/2025
SW ENG PRE APRON ¤30.00 03/21/2025
SW ENG - REVIEW 20 ¤20.00 03/21/2025
SW ENG RES REVIEW 200 ¤200.00 03/21/2025
SEWER CREDIT (¤650.00) 03/21/2025
SEWER INSPECTION ¤25.00 03/21/2025
SEWER CAPITAL FACILITY ¤6,120.52 03/21/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 03/21/2025
SITE PLAN 30 ¤30.00 03/21/2025
WATER- TURN ON ¤25.00 03/21/2025
ADJUSTMENT 10% (¤120.20) 03/21/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/21/2025
INSPECTION - RESIDENTIAL ¤913.00 03/21/2025
PLAN REVIEW - RESIDENTIAL ¤258.96 03/21/2025
Fees Total Due: ¤0.00 Total Paid: ¤22,789.25