I want to search for...
Permit #2025030617
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00120-0350 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00120 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 56 BALLENGER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/26/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 06/24/2025 | FINAL APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 06/23/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/23/2025 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/23/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/23/2025 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 06/20/2025 | FINAL APPROVED | JSTEWART |
| ELECTRIC - EARLY POWER | 06/12/2025 | APPROVED | KSANDOE |
| ROW- PRE-APRON (PRE-POUR) | 06/06/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: GRETSON IS GOING TO TAKE OUT ROCKS THAT ARE BIGGER THEN 1". IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------------------------------- 6/5/2025 - PREVIOUS INSPECTION NOTES THIS IS STILL NOT READY FOR INSPECTION TO MUCH WATER IN POURING AREA ----------------------------------------------------------------------------- New inspection due to canceled inspection ----------------------------------------------------------------------------- 6/2/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION AT THIS AT 9:52AM THERE ARE FORM BOARDS MISSING AT THIS TIME AND THE PIPE IS FULL OF WATER. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/05/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THIS IS STILL NOT READY FOR INSPECTION TO MUCH WATER IN POURING AREA ----------------------------------------------------------------------------- New inspection due to canceled inspection ----------------------------------------------------------------------------- 6/2/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION AT THIS AT 9:52AM THERE ARE FORM BOARDS MISSING AT THIS TIME AND THE PIPE IS FULL OF WATER. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/04/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 6/2/2025 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION AT THIS AT 9:52AM THERE ARE FORM BOARDS MISSING AT THIS TIME AND THE PIPE IS FULL OF WATER. | |||
| SEWER TIE IN | 06/04/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 Inspector Notes from Inspection 2060 REMOVE ALL VEGITATION BEFORE SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 06/03/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 REMOVE ALL VEGITATION BEFORE SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 06/02/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THIS IS NOT READY FOR INSPECTION AT THIS AT 9:52AM THERE ARE FORM BOARDS MISSING AT THIS TIME AND THE PIPE IS FULL OF WATER. | |||
| INSULATION | 05/30/2025 | APPROVED | HCAMACHO |
| ALL ROUGH | 05/28/2025 | APPROVED | JSTEWART |
| LATH/BRICK/ WATER BARRIER | 05/27/2025 | APPROVED | MCONTRYMAN |
| Note: 5/22/2025 - PREVIOUS INSPECTION NOTES NO LATH, WATER BARRIER INSTALLED. | |||
| ALL ROUGH | 05/27/2025 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 05/22/2025 | Disapproved - NO FEE | FWILLIS |
| Note: NO LATH, WATER BARRIER INSTALLED. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2025 | APPROVED | FWILLIS |
| Note: 5/15/2025 - PREVIOUS INSPECTION NOTES FBC [A]107.4 NOT READY - WORK INCOMPLETE 7 truss Hangers No Nails per plan 2 truss at front entry straps no nails per plan over framing piggyback trusses tie downs no nails. No 2x truss web engineering installed. per plan | |||
| ROOF VALLEY & METAL | 05/19/2025 | APPROVED | FWILLIS |
| U-CROSS CONNECTION | 05/19/2025 | APPROVED | DHANEY |
| WALL SHEATHING | 05/15/2025 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/15/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: FBC [A]107.4 NOT READY - WORK INCOMPLETE 7 truss Hangers No Nails per plan 2 truss at front entry straps no nails per plan over framing piggyback trusses tie downs no nails. No 2x truss web engineering installed. per plan | |||
| TIE BEAM / LINTEL | 05/07/2025 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 04/29/2025 | APPROVED | FWILLIS |
| Note: 4/28/2025 - PREVIOUS INSPECTION NOTES 1. Need a relieving arch at AC chase running thru foundation. FBCR P2603.4 2. Rebar at multiple corner terminates in or close to soil, requires 3" clearence. FBC R404.1.3.3.7.4 3. Clean a couple location of cave ins. FBC R404.1.3.3.7.4 4. Please compact EXCAVATED areas of pad. FBCR 506.2.1 5. Please relocate Job box or Portable restroom so Address is visible from the road. FBCR 319.1 | |||
| MONOLITHIC SLAB | 04/28/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Need a relieving arch at AC chase running thru foundation. FBCR P2603.4 2. Rebar at multiple corner terminates in or close to soil, requires 3" clearence. FBC R404.1.3.3.7.4 3. Clean a couple location of cave ins. FBC R404.1.3.3.7.4 4. Please compact EXCAVATED areas of pad. FBCR 506.2.1 5. Please relocate Job box or Portable restroom so Address is visible from the road. FBCR 319.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/24/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: REMOVE ALL VEGITATION BEFORE SLAB INSPECTION | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/22/2025 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/21/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 04/03/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 04/22/2025 | 04/22/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/22/2025 | 04/22/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/16/2025 | 04/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/25/2025 | 03/25/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/25/2025 | 03/25/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/25/2025 | 03/25/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/14/2025 | 03/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/14/2025 | 03/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/14/2025 | 03/14/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/14/2025 | 03/17/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/14/2025 | 03/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/14/2025 | 03/19/2025 |
| LOCATE | COMPLETE | 03/14/2025 | 03/19/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/14/2025 | 03/19/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/14/2025 | 03/20/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/14/2025 | 03/18/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM landscape plan: please remove hedges on Landscape as they seem to also be planted on the property next door. Site Plan: Propane tank can be buried but not in the Easement relocate the the tank | |||
| SWALE | COMPLETE | 03/14/2025 | 04/01/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/23/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/23/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/23/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/23/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/26/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/26/2025 |
| SEWER INSPECTION | ¤25.00 | 03/26/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 03/26/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 03/26/2025 |
| SITE PLAN 30 | ¤30.00 | 03/26/2025 |
| WATER- TURN ON | ¤25.00 | 03/26/2025 |
| ADJUSTMENT 10% | (¤120.20) | 03/26/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/26/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 03/26/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 03/26/2025 |
| CONNECTION FEES | ¤1,187.26 | 03/26/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 03/26/2025 |
| IMPACT FEE FIRE | ¤434.51 | 03/26/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/26/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/26/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 03/26/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/26/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 03/26/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/26/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 03/26/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 03/26/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/26/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/26/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/26/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,539.25 |