I want to search for...
Permit #2025030715
Permit Details
Status: COED
| Parcel Id: 07-11-31-7065-00150-0040 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 33 sqft |
| Total Square Footage: 2248 sqft |
| Block: 00150 |
| Subdivision: - |
| Job Phone: 239-571-5325 |
| Location Address: 22 KASHMIR TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/27/2025 |
| NOC: RECORDED |
| Applicant name: RYAN SCOTT DAVIS |
| Owner: SYNERGY HOMES LLC |
|
Address 581 NW MERCANTILE PLACE PORT SAINT LUCIE, FL 34986 |
|
Address SUITE 106 PORT SAINT LUCIE, FL 34986 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
SYNERGY HOMES, LLC
| Status | Location Address | State License Number |
| ACTIVE |
1 HARGROVE GRADE, SUITE B1 PALM COAST, FL 32137 |
CBC1254289 (Exp: 08/31/2026) |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 07/30/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/30/25 SOD HAS BEEN LAID IN AREAS REQUIRED. IT HAS BEEN DRY FOR A FEW DAYS SO IT IS HARD TO DETERMINE IF THE DRAINAGE WILL HAVE POSITIVE FORWARD FLOW,, BUT AT THE TIME OF THIS INSPECTIONS THE AFFECTED AREAS NOTED PREVIOUSLY HAVE BEEN RAKED AND RESODDE. I AM PASSING THIS AS NOTED THAT AT THE TIME OF THIS INSPECTION NO ADVERSE CONDITIONS ARE PRESENT, BUILDER ACCEPTS RESPONSIBILITY THAT DUE TO NUMEROUS LEFT SIDE REQUIRED CORRECTIONS THAT THEY ARE RESPONSIBLE FOR ANY CHANGES AFTER THIS INSPECTION. PHOTO FOR REFERENCE. *** INSPECTORS NOTE. YOU WILL BE RESPONSIBLE TO REPAIR MEDIAN BEFORE 20 KASHMIR ROW FINAL WILL BE ISSUED. *** 7/29/2025 - PREVIOUS INSPECTION NOTES 7/29/25 GRAYSON COMMUNICATED TO ME THAT THE REQUIRED REGRADING AND RESODDING WAS COMPLETED ON THE LEFT SIDE AND REAR. I DO NOT SEE ANY EVIDENCE THAT ANY REPAIR/REGRADE/RESOD WAS COMPLETED ON THE LEFT SIDE OR REAR AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 7/28/2025 - PREVIOUS INSPECTION NOTES 7/28/25 GRAYSON ASKED TO CANCEL THIS INSPECTION VIA TEXT. _______________________________________________________________________________________________________________________ 7/22/25 ***INSPECTORS NOTE. WALKED PROPERTY AFTER IT STOPPED RAINING TODAY AND THE DRAINAGE IS STILL NOT WORKING INTHE REAR LEFT CORNER AND LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. A COUPLE OF THE AREAS YOU ADDED DIDT TO APPEAR TO HAVE WASHED OUT. IN THE REAR THAT WATER IS STILL POOLING AND NOT MOVING FORWARD POSITIVELY. YOU WILL NEED TO REGRADE THIS AREA AND MAKE SURE IT MEETS COPC STANDARDS. *** | |||
| ROW - STORMWATER FINAL | 07/29/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 7/29/25 GRAYSON COMMUNICATED TO ME THAT THE REQUIRED REGRADING AND RESODDING WAS COMPLETED ON THE LEFT SIDE AND REAR. I DO NOT SEE ANY EVIDENCE THAT ANY REPAIR/REGRADE/RESOD WAS COMPLETED ON THE LEFT SIDE OR REAR AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. 7/28/2025 - PREVIOUS INSPECTION NOTES 7/28/25 GRAYSON ASKED TO CANCEL THIS INSPECTION VIA TEXT. _______________________________________________________________________________________________________________________ 7/22/25 ***INSPECTORS NOTE. WALKED PROPERTY AFTER IT STOPPED RAINING TODAY AND THE DRAINAGE IS STILL NOT WORKING INTHE REAR LEFT CORNER AND LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. A COUPLE OF THE AREAS YOU ADDED DIDT TO APPEAR TO HAVE WASHED OUT. IN THE REAR THAT WATER IS STILL POOLING AND NOT MOVING FORWARD POSITIVELY. YOU WILL NEED TO REGRADE THIS AREA AND MAKE SURE IT MEETS COPC STANDARDS. *** | |||
| ROW - STORMWATER FINAL | 07/28/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 7/28/25 GRAYSON ASKED TO CANCEL THIS INSPECTION VIA TEXT. _______________________________________________________________________________________________________________________ 7/22/25 ***INSPECTORS NOTE. WALKED PROPERTY AFTER IT STOPPED RAINING TODAY AND THE DRAINAGE IS STILL NOT WORKING INTHE REAR LEFT CORNER AND LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. A COUPLE OF THE AREAS YOU ADDED DIDT TO APPEAR TO HAVE WASHED OUT. IN THE REAR THAT WATER IS STILL POOLING AND NOT MOVING FORWARD POSITIVELY. YOU WILL NEED TO REGRADE THIS AREA AND MAKE SURE IT MEETS COPC STANDARDS. *** | |||
| U -UTILITY RESIDENTIAL FINAL | 07/22/2025 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No IRR. No CC | |||
| ROW - FINAL APRON (AFTER POUR) | 07/22/2025 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9465 7/22/25 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. __________________________________________________________________________________________________________________________ 7/21/25 SPOKE WITH GRAYSON CM HE HAD ASKED ME TO TAKE A LOOK AT THE LEFT SIDE DRAINAGE CONVEYANCE CORRECTION BEFORE SOD IS LAID. UPON WALKING PROPERTY DETERMINED THAT GRADE IS SHOWING FALL BY EYE. LET HIM KNOW I WILL PASS FIELD SURVEY AS NOTED THAT HE WILL RESET SOD, SHOOT FALL AND WE WILL GO FORWARD FROM THERE. ______________________________________________________________________________________________________________________ 7/15/2025 - PREVIOUS INSPECTION NOTES 7/15/25 NOTHING HAS CHANGED. YOU HAVE A LOW AREA IN THE BACK LEFT THAT NEEDS TO BE RAISED TO ALLOW POSITIVE FORWARD DRAINAGE. YOU ALSO HAVE A LOW/HIGH SPOT ON THE LEFT SIDE NEAR THE PEP TANK THAT IS NOT ALLOWING THE DRAINAGE CONVEYANCE TO FLOW. THESE AREAS WILL NEED TO BE CORRECTED BEFORE RESUBMITTING FOR REINSPECTION. PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** ENTIRE LEFT SIDE DRANAGE CONVEYANCE IS HOLDING WATER AND NOT FLOWING AS INDICATED ON FIANL SURVEY. BACK LEFT CORNER IS HOLDING A LARGE AMOUNT OF WATER AND WILL NEED TO BA RAISED UP AS TO FLOW DRAINAGE TO FRONT. I HAVE ATTACHED SOME PHOTOS AS WELL. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/21/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/21/25 SPOKE WITH GRAYSON CM HE HAD ASKED ME TO TAKE A LOOK AT THE LEFT SIDE DRAINAGE CONVEYANCE CORRECTION BEFORE SOD IS LAID. UPON WALKING PROPERTY DETERMINED THAT GRADE IS SHOWING FALL BY EYE. LET HIM KNOW I WILL PASS FIELD SURVEY AS NOTED THAT HE WILL RESET SOD, SHOOT FALL AND WE WILL GO FORWARD FROM THERE. ______________________________________________________________________________________________________________________ 7/15/2025 - PREVIOUS INSPECTION NOTES 7/15/25 NOTHING HAS CHANGED. YOU HAVE A LOW AREA IN THE BACK LEFT THAT NEEDS TO BE RAISED TO ALLOW POSITIVE FORWARD DRAINAGE. YOU ALSO HAVE A LOW/HIGH SPOT ON THE LEFT SIDE NEAR THE PEP TANK THAT IS NOT ALLOWING THE DRAINAGE CONVEYANCE TO FLOW. THESE AREAS WILL NEED TO BE CORRECTED BEFORE RESUBMITTING FOR REINSPECTION. PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** ENTIRE LEFT SIDE DRANAGE CONVEYANCE IS HOLDING WATER AND NOT FLOWING AS INDICATED ON FIANL SURVEY. BACK LEFT CORNER IS HOLDING A LARGE AMOUNT OF WATER AND WILL NEED TO BA RAISED UP AS TO FLOW DRAINAGE TO FRONT. I HAVE ATTACHED SOME PHOTOS AS WELL. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/15/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 7/15/25 NOTHING HAS CHANGED. YOU HAVE A LOW AREA IN THE BACK LEFT THAT NEEDS TO BE RAISED TO ALLOW POSITIVE FORWARD DRAINAGE. YOU ALSO HAVE A LOW/HIGH SPOT ON THE LEFT SIDE NEAR THE PEP TANK THAT IS NOT ALLOWING THE DRAINAGE CONVEYANCE TO FLOW. THESE AREAS WILL NEED TO BE CORRECTED BEFORE RESUBMITTING FOR REINSPECTION. PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ 7/14/2025 - PREVIOUS INSPECTION NOTES 07/14/25 TPOLACEK*** ENTIRE LEFT SIDE DRANAGE CONVEYANCE IS HOLDING WATER AND NOT FLOWING AS INDICATED ON FIANL SURVEY. BACK LEFT CORNER IS HOLDING A LARGE AMOUNT OF WATER AND WILL NEED TO BA RAISED UP AS TO FLOW DRAINAGE TO FRONT. I HAVE ATTACHED SOME PHOTOS AS WELL. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/14/2025 | APPROVED | TPOLACEK |
| Note: Inspector Notes from Inspection 9270 6/20/25 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVER DETAIL. 6/10/2025 - PREVIOUS INSPECTION NOTES 6/10/25 YOUR APRON WING SLOPES ON BOTH SIDES EXCEED THE COPC 8% ALLOWABLE STANDARD AT THE TIME OF THIS INSPECTION. YOU HAVE CONCRETE CHUNKS NOT 57 STONE ALONG AND AROUND YOUR CULVERT PIPE. THIESE ARE TOO BIG INCONSISTENT AND NOT ALLOWED AS CULVERT PIPE STABILIZER. YOU WILL NEED TO CLEAN OUT ALL CHUNKS BIGGER THAN 3.5". PIPE ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ New inspection due to canceled inspection 6/2/2025 - PREVIOUS INSPECTION NOTES 6/2/25 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION. PLEASE RESUBMIT WHEN IT IS READY. SEE PHOTO FOR REFERENCE. 5/29/2025 - PREVIOUS INSPECTION NOTES 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/14/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 07/14/25 TPOLACEK*** ENTIRE LEFT SIDE DRANAGE CONVEYANCE IS HOLDING WATER AND NOT FLOWING AS INDICATED ON FIANL SURVEY. BACK LEFT CORNER IS HOLDING A LARGE AMOUNT OF WATER AND WILL NEED TO BA RAISED UP AS TO FLOW DRAINAGE TO FRONT. I HAVE ATTACHED SOME PHOTOS AS WELL. | |||
| BLD - BUILDING FINAL | 07/07/2025 | FINAL APPROVED | BTAYLOR |
| Note: 7/3/2025 - PREVIOUS INSPECTION NOTES 7-3-25 1. No water at Kitchen sink fixture. FBCR P2705.1 – 4 7/2/2025 - PREVIOUS INSPECTION NOTES 1. Please have garage door opener powered up for test of devices (uncover devices). R309.4 / UL 325 2. Please install AC Thermostat, and have AC cycling. Per plan 3. Master exhaust fan Not functioning. FBC M1507 4. Spare bath exhaust fan Not functioning. FBC M1507 5. No water at Kitchen sink fixture. FBCR P2705.1 – 4 | |||
| BLD - BUILDING FINAL | 07/03/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 7-3-25 1. No water at Kitchen sink fixture. FBCR P2705.1 – 4 7/2/2025 - PREVIOUS INSPECTION NOTES 1. Please have garage door opener powered up for test of devices (uncover devices). R309.4 / UL 325 2. Please install AC Thermostat, and have AC cycling. Per plan 3. Master exhaust fan Not functioning. FBC M1507 4. Spare bath exhaust fan Not functioning. FBC M1507 5. No water at Kitchen sink fixture. FBCR P2705.1 – 4 | |||
| BLD - BUILDING FINAL | 07/02/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Please have garage door opener powered up for test of devices (uncover devices). R309.4 / UL 325 2. Please install AC Thermostat, and have AC cycling. Per plan 3. Master exhaust fan Not functioning. FBC M1507 4. Spare bath exhaust fan Not functioning. FBC M1507 5. No water at Kitchen sink fixture. FBCR P2705.1 – 4 | |||
| GRAVITY SEWER TEST | 06/23/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 06/23/2025 | APPROVED | MGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 06/20/2025 | APPROVED - AS NOTED | RRICKS |
| Note: 6/20/25 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVER DETAIL. 6/10/2025 - PREVIOUS INSPECTION NOTES 6/10/25 YOUR APRON WING SLOPES ON BOTH SIDES EXCEED THE COPC 8% ALLOWABLE STANDARD AT THE TIME OF THIS INSPECTION. YOU HAVE CONCRETE CHUNKS NOT 57 STONE ALONG AND AROUND YOUR CULVERT PIPE. THIESE ARE TOO BIG INCONSISTENT AND NOT ALLOWED AS CULVERT PIPE STABILIZER. YOU WILL NEED TO CLEAN OUT ALL CHUNKS BIGGER THAN 3.5". PIPE ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ New inspection due to canceled inspection 6/2/2025 - PREVIOUS INSPECTION NOTES 6/2/25 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION. PLEASE RESUBMIT WHEN IT IS READY. SEE PHOTO FOR REFERENCE. 5/29/2025 - PREVIOUS INSPECTION NOTES 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| ELECTRIC - EARLY POWER | 06/12/2025 | APPROVED | KSANDOE |
| ROW- PRE-APRON (PRE-POUR) | 06/10/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 6/10/25 YOUR APRON WING SLOPES ON BOTH SIDES EXCEED THE COPC 8% ALLOWABLE STANDARD AT THE TIME OF THIS INSPECTION. YOU HAVE CONCRETE CHUNKS NOT 57 STONE ALONG AND AROUND YOUR CULVERT PIPE. THIESE ARE TOO BIG INCONSISTENT AND NOT ALLOWED AS CULVERT PIPE STABILIZER. YOU WILL NEED TO CLEAN OUT ALL CHUNKS BIGGER THAN 3.5". PIPE ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION. SEE PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________ New inspection due to canceled inspection 6/2/2025 - PREVIOUS INSPECTION NOTES 6/2/25 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION. PLEASE RESUBMIT WHEN IT IS READY. SEE PHOTO FOR REFERENCE. 5/29/2025 - PREVIOUS INSPECTION NOTES 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 06/04/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 6/2/2025 - PREVIOUS INSPECTION NOTES 6/2/25 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION. PLEASE RESUBMIT WHEN IT IS READY. SEE PHOTO FOR REFERENCE. 5/29/2025 - PREVIOUS INSPECTION NOTES 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 06/02/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 6/2/25 THIS SITE IS NOT READY FOR A PREPOUR INSPECTION. PLEASE RESUBMIT WHEN IT IS READY. SEE PHOTO FOR REFERENCE. 5/29/2025 - PREVIOUS INSPECTION NOTES 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| PEP TANK INSTALLATION REQUEST | 05/30/2025 | APPROVED | CBOWERMASTER |
| Note: 5/29/2025 2:55:43 PM- PREVIOUS INSPECTION NOTES stucco needs to be done | |||
| PEP TANK INSTALLATION REQUEST | 05/29/2025 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: stucco needs to be done | |||
| INSULATION | 05/29/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/29/2025 10:52:24 AM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/27/2025 2:34:33 PM *** 5/27/25: Check at Insulation!!! 1). 5ft head pressure not holding. 2). Bathtub needs to be filled to the overflow. 3). Missing nail plates at top plate wire penetration in garage. Studs marked NP. 5/23/2025 - PREVIOUS INSPECTION NOTES Not ready. Crews still working | |||
| ROW- PRE-APRON (PRE-POUR) | 05/29/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 5/29/25 RECEIVED TEXT FROM GRAYSON CM TO PLEASE CANCEL THIS INSPECTION FOR TODAY. ________________________________________________________________________________________________________________________ 5/28/2025 - PREVIOUS INSPECTION NOTES ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/28/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 05/28/25 TOO MUCH WATER IN (ROW) APRON AREA OF POUR FOOT SINKS IN MUD IN APRON AND AROUND CULVERT PUSHING OUT WATER. CULVERT FULL OF WATER ** NEED TO EITHER ADD ADDITIONAL FORM BOARDS OR BACK FILL FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 4 INCHES IN ENTIRE DRIVEWAY POUR AREA ABOVE THE ROW AND 6 INCHES IN APRON ** SEE ATTACHED POTOS | |||
| LATH/BRICK/ WATER BARRIER | 05/27/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/27/2025 2:32:56 PM *** 5/23/2025 - PREVIOUS INSPECTION NOTES Not ready. Crews still working | |||
| ALL ROUGH | 05/27/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/27/2025 2:34:33 PM *** 5/27/25: Check at Insulation!!! 1). 5ft head pressure not holding. 2). Bathtub needs to be filled to the overflow. 3). Missing nail plates at top plate wire penetration in garage. Studs marked NP. 5/23/2025 - PREVIOUS INSPECTION NOTES Not ready. Crews still working | |||
| ALL ROUGH | 05/23/2025 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Not ready. Crews still working | |||
| LATH/BRICK/ WATER BARRIER | 05/23/2025 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Not ready. Crews still working | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/22/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| ROOF VALLEY & METAL | 05/19/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1- Multiples shiners over garage roof area and arouns lets bedroom and leavinf room roof deck #2- H clips need to be install correctly 5/16/2025 - PREVIOUS INSPECTION NOTES 5/16/25: Partial Approval due to Roof Sheathing. 2). Roof sheathing is missing 'H' clips in numerous areas along with gaps between sheathing panels not meeting code requirements for expansion. FBC-R904.5.3 / FBC [A]107.4 | |||
| WALL SHEATHING | 05/16/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/16/2025 2:02:22 PM *** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/16/2025 | PARTIALLY APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/16/2025 2:19:26 PM *** 5/16/25: Partial Approval due to Roof Sheathing. 1). Roof Sheathing has a great deal of shiners that need to be fully removed and re-nail where removed if necessary. 2). Roof sheathing is missing 'H' clips in numerous areas along with gaps between sheathing panels not meeting code requirements for expansion. FBC-R904.5.3 / FBC [A]107.4 | |||
| U-CROSS CONNECTION | 05/16/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: No IRR. No CC | |||
| TIE BEAM / LINTEL | 05/06/2025 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2250 4/28/25 Please move port-jon to center of both sites for access | |||
| MONOLITHIC SLAB | 04/29/2025 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 04/28/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/28/25 Please move port-jon to center of both sites for access | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/22/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/21/2025 | APPROVED | JMUNSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/16/2025 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 04/04/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/16/2025 | 04/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/15/2025 | 04/16/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/15/2025 | 04/15/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/26/2025 | 03/26/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/26/2025 | 03/26/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/26/2025 | 03/26/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No zoning chnages only stormwater | |||
| SWALE | COMPLETE | 03/18/2025 | 04/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/17/2025 | 03/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/17/2025 | 03/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/17/2025 | 03/18/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/17/2025 | 03/18/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/17/2025 | 03/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/17/2025 | 03/19/2025 |
| LOCATE | COMPLETE | 03/17/2025 | 03/20/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/17/2025 | 03/19/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 03/17/2025 | 03/20/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM 1. Missing proposed elevations on the back property line at both corners. 2. Missing 10' shots outside property line on vacant lot | |||
| ZON | COMPLETE | 03/17/2025 | 03/20/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/30/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/28/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/28/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/28/2025 |
| UTILITY PEP REINSPECTION | ¤40.00 | 07/28/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/28/2025 |
| CONNECTION FEES | ¤1,187.26 | 03/27/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 03/27/2025 |
| IMPACT FEE FIRE | ¤434.51 | 03/27/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/27/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/27/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 03/27/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/27/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 03/27/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/27/2025 |
| SURCHARGE FS 533.721 | ¤10.82 | 03/27/2025 |
| SURCHARGE - FS 468.631 | ¤16.23 | 03/27/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/27/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/27/2025 |
| SW ENG PRE APRON | ¤30.00 | 03/27/2025 |
| SEWER INSPECTION | ¤25.00 | 03/27/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 03/27/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 03/27/2025 |
| SITE PLAN 30 | ¤30.00 | 03/27/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/27/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/27/2025 |
| WATER- TURN ON | ¤25.00 | 03/27/2025 |
| ADJUSTMENT 10% | (¤120.20) | 03/27/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/27/2025 |
| INSPECTION - RESIDENTIAL | ¤913.00 | 03/27/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤258.96 | 03/27/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,689.25 |