Permit #2025030842
Permit Details
Status: FINAL
| Parcel Id: 04-11-30-5160-00000-1980 |
| Subdivision: 5160 - |
| Job Phone: 904-864-9366 |
| Location Address: 3 AUCILLA PL |
| Type: GEN - GENERATOR |
| Issue Date: 04/29/2025 |
| NOC: RECORDED |
| Applicant name: JACOB HURLEY |
| Owner: BENJAMIN STEPHEN ELDRIDGE & CHRISTINE ELISE AMC |
|
Address 3 AUCILLA PLACE PALM COAST, FL 32137 |
| Lot: 198 |
| Contracted Stated Job Value: ¤14,000.00 |
| Job Description: 22KW Generac Generator Existing Natural Gas |
| Type: CN |
Contractor
GENERATOR SUPERCENTER OF JACKSONVILLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
8081 PHILLIPS HWY STE 1 JACKSONVILLE, FL 32256 |
EC13009708 (Exp: 08/31/2026) | 904-379-4189 |
Sub Contractors
JACOB HURLEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
8081 PHLIPS HWY SUITE 1 , 0 |
LI45162 (Exp: 10/26/2028) | 904-379-4189 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 08/20/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/20/2025 3:31:46 PM *** | |||
| GAS FINAL | 08/20/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/20/2025 3:31:58 PM *** | |||
| ELECTRIC FINAL | 08/15/2025 | CANCELLED BY APPLICANT | WEB |
| GAS FINAL | 08/15/2025 | CANCELLED BY APPLICANT | WEB |
| GAS ROUGH | 05/12/2025 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 05/09/2025 | 05/09/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME FILE NAME TO NOC.PDF | |||
| GAS | COMPLETE | 04/28/2025 | 04/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/23/2025 | 04/24/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| GAS | HOLD | 04/23/2025 | 04/25/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM list gas subcontractor in portal | |||
| ZON | HOLD | 04/14/2025 | 04/14/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Please add the setbacks from the proposed generator to adjacent property lines. | |||
| ELEC | COMPLETE | 04/14/2025 | 04/15/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| GAS | HOLD | 04/14/2025 | 04/15/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Gas riser needs to have an address on it | |||
| ZON | HOLD | 04/09/2025 | 04/09/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Please use final survey from when the home was completed in Nov 2024 (you can find the permit on the building portal). Show the entire property as your site plan and add the setbacks from the proposed generator to adjacent property lines. | |||
| GAS | HOLD | 04/09/2025 | 04/14/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide gas riser diagram (GAS WAS NOT PERMITTED UNDER THE HOUSE PERMIT. PROVIDE RISER DIAGRAM AND LIST GAS SUBCONTACTOR OR HAVE GAS COMPANY APPLY FOR SEPARATE PERMIT) 2. Provide note on plans that generator exhaust must be minimum 10ft from any opening into the building per FBC Residential 2023 8Th edition M1905.2.5. If using the exception to 5ft, carbon monoxide detectors will be inspected on generator final. (SECOND REQUEST) | |||
| ELEC | HOLD | 04/09/2025 | 04/10/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. #4 copper is nos not rated for the 100 amp breaker. EC 2020 310.16 2nd REQUEST | |||
| ELEC | HOLD | 03/19/2025 | 03/25/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. #4 copper is nos not rated for the 100 amp breaker. EC 2020 310.16 2. Submit manufacture specs for 22 KW not the 26 | |||
| GAS | HOLD | 03/19/2025 | 03/24/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide gas riser diagram 2. Provide note on plans that generator exhaust must be minimum 10ft from any opening into the building per FBC Residential 2023 8Th edition M1905.2.5. If using the exception to 5ft, carbon monoxide detectors will be inspected on generator final. | |||
| ZON | HOLD | 03/19/2025 | 03/19/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please use final survey from when the home was completed in Nov 2024 (you can find the permit on the building portal). Show the entire property as your site plan and add the setbacks from the proposed generator to adjacent property lines. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤12.25) | 04/29/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/29/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 04/29/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 04/29/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 04/29/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/29/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/29/2025 |
| SITE PLAN 15 | ¤15.00 | 04/29/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤149.25 |