Permit #2025030846
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7063-00680-0110 |
| Block: 00680 |
| Subdivision: 7063 - |
| Job Phone: 386-479-7149 |
| Location Address: 48 ZEBULAHS TRL |
| Type: EL - ELECTRICAL |
| Issue Date: 03/20/2025 |
| NOC: Unknown |
| Applicant name: TIMOTHY RYAN GODFREY |
| Owner: JUSTINIANO ROSARIO YESENIA E & CELIO A CENTENO LUG |
|
Address 48 ZEBULAHS TRL PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤850.00 |
| Job Description: Provide and install 240volt 50amp EV charger and circuitry next to panelingarage |
| Type: CN |
Contractor
POWERFULL RECHARGE, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
255 MARGARITAVILLE AVE DAYTONA BEACH, FL 32124 |
EC13012049 (Exp: 08/31/2026) | 386-479-7149 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 04/30/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/30/2025 12:54:49 PM *** 4/30/25: 1). Permit and Manufacturer's specification documents need to be on site for inspection. FBC [A]107.3.1 2). Connector in breaker panel for EV charger feed is not installed properly and does not meet code requirements for application. NEC-334.30 3). Missing connector/clamp at EV charger for SJO cord. NEC-334.30 4). SJO cord feed to charger head needs to be in a raceway in order to protect it from damage. NEC 300.4 5). Hole through the drywall and framing at the side of the breaker box for EV charger feed needs to be Firestopped with approved material. FBC-302.11(4). 6). Both EV charger feed wire and EV charger plug feed need to be secured to the wall within 12" of the charger box. NEC 350.30(A) 7). Due to missing documentation maximum breaker could not be determined. FBC [A]107.3.1 8). Breaker box cover panel had loose and partially stripped screws prior to removal for inspection. Screws are now properly installed. Please assure that cover screws are installed as required. FBC [A]107.4 / NEC-314.25 | |||
| ELECTRIC FINAL | |||
| Note: 4/30/2025 - PREVIOUS INSPECTION NOTES 4/30/25: 1). Permit and Manufacturer's specification documents need to be on site for inspection. FBC [A]107.3.1 2). Connector in breaker panel for EV charger feed is not installed properly and does not meet code requirements for application. NEC-334.30 3). Missing connector/clamp at EV charger for SJO cord. NEC-334.30 4). SJO cord feed to charger head needs to be in a raceway in order to protect it from damage. NEC 300.4 5). Hole through the drywall and framing at the side of the breaker box for EV charger feed needs to be Firestopped with approved material. FBC-302.11(4). 6). Both EV charger feed wire and EV charger plug feed need to be secured to the wall within 12" of the charger box. NEC 350.30(A) 7). Due to missing documentation maximum breaker could not be determined. FBC [A]107.3.1 8). Breaker box cover panel had loose and partially stripped screws prior to removal for inspection. Screws are now properly installed. Please assure that cover screws are installed as required. FBC [A]107.4 / NEC-314.25 |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 03/19/2025 | 03/19/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤12.25) | 03/20/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/20/2025 |
| INSPECTION- ELECTRICAL | ¤60.00 | 03/20/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 03/20/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/20/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤114.25 |