I want to search for...

Permit #2025030846

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7063-00680-0110
Block: 00680
Subdivision: 7063 -
Job Phone: 386-479-7149
Location Address: 48 ZEBULAHS TRL
Type: EL - ELECTRICAL
Issue Date: 03/20/2025
NOC: Unknown
Applicant name: TIMOTHY RYAN GODFREY
Owner: JUSTINIANO ROSARIO YESENIA E & CELIO A CENTENO LUG

Address

48 ZEBULAHS TRL

PALM COAST, FL 32164

Lot: 0110
Contracted Stated Job Value: ¤850.00
Job Description: Provide and install 240volt 50amp EV charger and circuitry next to panelingarage
Type: CN

Contractor

POWERFULL RECHARGE, LLC
Status Location Address State License Number Phone
INACTIVE

255 MARGARITAVILLE AVE

DAYTONA BEACH, FL 32124

EC13012049 (Exp: 08/31/2026) 386-479-7149

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 04/30/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/30/2025 12:54:49 PM *** 4/30/25: 1). Permit and Manufacturer's specification documents need to be on site for inspection. FBC [A]107.3.1 2). Connector in breaker panel for EV charger feed is not installed properly and does not meet code requirements for application. NEC-334.30 3). Missing connector/clamp at EV charger for SJO cord. NEC-334.30 4). SJO cord feed to charger head needs to be in a raceway in order to protect it from damage. NEC 300.4 5). Hole through the drywall and framing at the side of the breaker box for EV charger feed needs to be Firestopped with approved material. FBC-302.11(4). 6). Both EV charger feed wire and EV charger plug feed need to be secured to the wall within 12" of the charger box. NEC 350.30(A) 7). Due to missing documentation maximum breaker could not be determined. FBC [A]107.3.1 8). Breaker box cover panel had loose and partially stripped screws prior to removal for inspection. Screws are now properly installed. Please assure that cover screws are installed as required. FBC [A]107.4 / NEC-314.25
ELECTRIC FINAL
Note: 4/30/2025 - PREVIOUS INSPECTION NOTES 4/30/25: 1). Permit and Manufacturer's specification documents need to be on site for inspection. FBC [A]107.3.1 2). Connector in breaker panel for EV charger feed is not installed properly and does not meet code requirements for application. NEC-334.30 3). Missing connector/clamp at EV charger for SJO cord. NEC-334.30 4). SJO cord feed to charger head needs to be in a raceway in order to protect it from damage. NEC 300.4 5). Hole through the drywall and framing at the side of the breaker box for EV charger feed needs to be Firestopped with approved material. FBC-302.11(4). 6). Both EV charger feed wire and EV charger plug feed need to be secured to the wall within 12" of the charger box. NEC 350.30(A) 7). Due to missing documentation maximum breaker could not be determined. FBC [A]107.3.1 8). Breaker box cover panel had loose and partially stripped screws prior to removal for inspection. Screws are now properly installed. Please assure that cover screws are installed as required. FBC [A]107.4 / NEC-314.25

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/19/2025 03/19/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 03/20/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/20/2025
INSPECTION- ELECTRICAL ¤60.00 03/20/2025
PLAN REVIEW - MISC 32.50 ¤32.50 03/20/2025
SURCHARGE FS 533.721 ¤2.00 03/20/2025
SURCHARGE - FS 468.631 ¤2.00 03/20/2025
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤114.25