Permit #2025030867

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7035-00130-0310
Total Square Footage: 816 sqft
Block: 00130
Subdivision: 7035 -
Job Phone: 386-283-1059
Location Address: 35 BURNING BUSH DR
Type: BA - BUILDING ADDITION
Issue Date: 05/30/2025
NOC: RECORDED
Applicant name: MICHAEL JORDAN HUBER
Owner: COLLINS JILL L & CYNTHIA M LAWRENCE JTWROS

Address

35 BURNING BUSH DRIVE

PALM COAST, FL 32137

Lot: 0310
Contracted Stated Job Value: ¤200,000.00
Job Description: DETACHED BUILDING ADDITION
Type: CN

Contractor

HUBCO BUILDING & REMODELING, LLC
Status Location Address State License Number Phone
ACTIVE

2553 GREENTREE STREET

BUNNELL, FL 32110

CRC1330947 (Exp: 08/31/2026) 386-283-1059

Sub Contractors

SCOTT R WOODARD
Status Location Address State License Number Phone
ACTIVE

51 PINEAPPLE DRIVE

PALM COAST, FL 32164

ES12000383 (Exp: 08/31/2026) 386-264-4964
GIOVANNI DISARRO
Status Location Address State License Number
INACTIVE

107 BURROUGHS DRIVE

PALM COAST, FL 32137

CFC1430761 (Exp: 08/31/2026)
KENNETH R LEWIS
Status Location Address State License Number Phone Fax
ACTIVE

1281 N US HIGHWAY 1

ORMOND BEACH, FL 32174

CCC1327557 (Exp: 08/31/2026) 386-274-1001 386-274-1094
WILLIAM LEE MILLER JR
Status Location Address State License Number Phone
ACTIVE

8 SEAFARING PATH

BUNNELL, FL 32210

CAC1820053 (Exp: 08/31/2026) 386-864-8090

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/28/2026 FINAL APPROVED MCONTRYMAN
U -UTILITY RESIDENTIAL FINAL 01/28/2026 FINAL APPROVED BWRIGHT
ROW FIELD SURVEY /GRADING CERTIFICATION 01/26/2026 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 1/12/2026 - PREVIOUS INSPECTION NOTES 01-12-26 TPOLACEK*** APPROVED SITE PLAN PROPOSED DRAINAGE PATTERN IS NOT REFLECTED ON FINAL SURVEY. DRAINAGE IS REQUIRED TO FLOW OUT TO THE FRONT ROADSIDE SWALE. THE PROPSED ELEVATIONS ON SITE PLAN INDICATE A SWALE OF .30 THAT MEETS REQUIREMENTS AND THE FINAL SURVEY DOES NOT SHOW THIS FEATURE.
ROW - FINAL INSPECTION 01/26/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/14/2026 APPROVED - AS NOTED TPOLACEK
Note: 1/12/2026 - PREVIOUS INSPECTION NOTES 01-12-26 TPOLACEK*** APPROVED SITE PLAN PROPOSED DRAINAGE PATTERN IS NOT REFLECTED ON FINAL SURVEY. DRAINAGE IS REQUIRED TO FLOW OUT TO THE FRONT ROADSIDE SWALE. THE PROPSED ELEVATIONS ON SITE PLAN INDICATE A SWALE OF .30 THAT MEETS REQUIREMENTS AND THE FINAL SURVEY DOES NOT SHOW THIS FEATURE.
ROW- PROJECT STATUS 01/14/2026 Status Check TPOLACEK
Note: 01-14-26 TPOLACEK*** MET WITH CONTRACTOR AND HOME OWNERS TO DISCUSS GRADE ACROSS THE BACK OF STRUCTURE. BUILDER WILL CREATE A SMALL SWALE FROM THE SIDEWALK TO THE SIDE YARD TO HELP DRAINAGE ESCAPE FROM THE BACK YARD. THE FINAL SURVEY DOES NOT CAPTURE THE AREA CORRECTLY DUE TO TREES AND SIDEWALKS. ONCE THE CORRECTIONS ARE MADE THE FIELD SURVEY CAN BE SCHEDULED TO MAKE SURE DRAINAGE REACHES THE SIDE YARD WHERE IT WILL DRAIN ACROSS AND REACH THE ROADSIDE SWALE ANY QUESTIONS PLEASE CALL TPOLACEK.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/12/2026 Disapproved - NO FEE TPOLACEK
Note: 01-12-26 TPOLACEK*** APPROVED SITE PLAN PROPOSED DRAINAGE PATTERN IS NOT REFLECTED ON FINAL SURVEY. DRAINAGE IS REQUIRED TO FLOW OUT TO THE FRONT ROADSIDE SWALE. THE PROPSED ELEVATIONS ON SITE PLAN INDICATE A SWALE OF .30 THAT MEETS REQUIREMENTS AND THE FINAL SURVEY DOES NOT SHOW THIS FEATURE.
SHOWER PAN 10/28/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
TUB SET 10/27/2025 CANCELLED BY APPLICANT MGIBSON
Note: CANCELD VIA TEXT MESSAGE
SEWER SERVICE 10/22/2025 APPROVED MGIBSON
INSULATION 09/25/2025 APPROVED JSTEWART
Note: 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25: Please fix previous items prior to re-inspection. #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval. (Has only been accepted as of today's inspection - needs to be approved by the City). #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ALSO: * Missing fireblocking at dryer exhaust upper opening in top plate. FBC-R302.11 9/22/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL
INSULATION 09/23/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/23/2025 12:54:39 PM *** 9/23/25: Please fix previous items prior to re-inspection. #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval. (Has only been accepted as of today's inspection - needs to be approved by the City). #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ALSO: * Missing fireblocking at dryer exhaust upper opening in top plate. FBC-R302.11 9/22/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL
INSULATION 09/22/2025 CANCELLED BY APPLICANT FWILLIS
Note: Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL
LATH/BRICK/ WATER BARRIER 09/19/2025 APPROVED - AS NOTED JSTEWART
Note: Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL
ALL ROUGH 09/17/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBCR M1308.2 & FBCR M1502.5 -NEEDS NAIL GUARD - PROPER SIZE AND THICKNESS ( by AH drainage pipe , Romex wire on walls , by Dryer vent #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS #3-Resumit FL approval documents for revision and approval #4-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( please resumit documents for revision and approval , ) #5-FBCR P2605.1-PIPE SUPPORT- PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL
ROOF VALLEY & METAL 09/17/2025 APPROVED CVANSTRAHLEN
Note: 8/15/2025 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING 08/15/2025 APPROVED FWILLIS
Note: 8/8/2025 - PREVIOUS INSPECTION NOTES
ROOF VALLEY & METAL 08/15/2025 CANCELLED BY APPLICANT FWILLIS
ROOF SHEATHING 08/08/2025 CANCELLED BY APPLICANT JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/01/2025 APPROVED MCONTRYMAN
MONOLITHIC SLAB 06/23/2025 APPROVED MCONTRYMAN
PLUMBING 1ST ROUGH UNDERGROUND 06/20/2025 APPROVED JSTEWART
ELECTRIC 1ST ROUGH UNDERGROUND 06/20/2025 APPROVED - AS NOTED JSTEWART
Note: Underground Conduit only.

Review History

Department Status Date In Date Out
MECH COMPLETE 09/23/2025 09/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/22/2025 09/23/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 09/17/2025 09/22/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Address missing on Product Approval Form
ELEC COMPLETE 08/28/2025 09/04/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 08/11/2025 08/13/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Be more specific of what you are changing on the riser diagram.
ZON COMPLETE 05/16/2025 05/16/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 05/12/2025 05/14/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring in the originals for the single family affadavit
BLD COMPLETE 05/12/2025 05/16/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 05/02/2025 05/06/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 05/02/2025 05/05/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Plan: Please remove Kitchen as we do not allow cook top. You may have a wet bar and have a microwave and refridgerator but no stoves or ovens. the foundation side of the floor plans show a cook top still. Single family affadavit: Bring in originals.
MECH COMPLETE 05/02/2025 05/05/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 05/02/2025 05/05/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 05/02/2025 05/06/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) 2. OK 3. Roofing Worksheet. FL# 10626.1 is not self adhering underlayment 4. OK
ELEC COMPLETE 05/02/2025 05/05/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 05/02/2025 05/02/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM file name shoudl mathc docs your sumitting no nasmes or address rename file names
ENGIN1 COMPLETE 05/02/2025 05/12/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 03/20/2025 03/25/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please upload truss packet. Also, truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) 2. FL# 243 not a casement window. 3. Please upload Roofing Worksheet. 4. Load bearing wall & footing section detail calls for Tyvek and hardie board siding. Elevation drawings call for stucco to match house. Please clarify what elevation will be used.
ELEC HOLD 03/20/2025 03/25/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 03/20/2025 03/25/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
GAS CANCEL 03/20/2025 03/25/2025
MECH HOLD 03/20/2025 03/25/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition 2. Provide locations of evaporator coils on layout 3. Plans show R38 insulation in attic. Energy Calcs say R30. Revise to match
PLUM HOLD 03/20/2025 03/25/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide plumbing riser diagram showing attachmet to existing home for water service and sewer
SW1 HOLD 03/20/2025 03/24/2025
Note: Held By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM 03/24/25 BUILDER NEEDS AN UPDATED SURVEY OF PROPERTY THAT IS NO MORE THAN 1 YEAR OLD. BUILDER ALSO NEED TO ESTABLISH THE PROPOSED DRAINAGE PLAN AND SHOW HOW THE PROPERTY WILL DRAIN WITHOUT HAVING A NEGATIVE IMPACT ON ANY ADJACENT PROPERTY YOU WILL ALSO BE REQUIRED TO SUBMITTED A FINAL SURVEY ONCE THE PROJECVT IS COMPLETED SHOWING YOUR DRAINAGE .
ZON HOLD 03/20/2025 03/24/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan: Provide the front setback from proposed addition to front property line and the Left hand side as well. Please remove the word Accessory Dwelling Unit as they are not allowed in the City of Palm Coast. We do allow additions ( mother in law suites) please romove ADU from the description also. Currently as proposed the addition is being built directly on the easement, if this is how you would like it you will have to go through the process of releasing the easement with all three utility companies. Please look at the binding lot documentation as it will guide you on how to do that. If you decide to move it over the easement line you would not have to do all that and just make the correct adjustments to your plan. Please show all walkways and door pad on sitel plan Plan: Plese remove Kitchen as we do not allow cook top. You may have a wet bar and have a microwave and refridgerator but no stoves or ovens. Single family affadavit: this disclosure will need to be filled out. please upload once approved electronically, we will request originals for recording.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤73.60) 05/30/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/30/2025
INSPECTION - RESIDENTIAL ¤550.00 05/30/2025
PLAN REVIEW - RESIDENTIAL ¤156.00 05/30/2025
RECORDING FEE REIMBURSE DOC ¤10.00 05/30/2025
SURCHARGE FS 533.721 ¤6.62 05/30/2025
SURCHARGE - FS 468.631 ¤9.94 05/30/2025
SW ENG - INSPECTION 20 ¤20.00 05/30/2025
SW ENG - REVIEW 20 ¤20.00 05/30/2025
SITE PLAN 30 ¤30.00 05/30/2025
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤758.96