Permit #2025030900

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00280-0180
GARAGE: 542 sqft
CONDITIONED SPACE: 1311 sqft
CONDITIONED SPACE: 1311 sqft
GARAGE: 542 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
Total Square Footage: 4138 sqft
Block: 00280
Subdivision: -
Job Phone: 386-585-2654
Location Address: 35 FRENEAU LN
Type: DU - DUPLEX
Issue Date: 05/05/2025
NOC: RECORDED
Applicant name: DESIDERIO CARLOS CARREIRO
Owner: REMEDIOS CARLOS & TERESA H&W

Address

24 BUBENKO LANE

GARNERVILLE, NY 10923

Lot: 0180
Contracted Stated Job Value: ¤400,000.00
Job Description: DUPLEX
Type: CN

Contractor

RED LINE CONSTRUCTION CO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Sub Contractors

DESIDERIO CARLOS CARREIRO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654
FERNANDO M FARIA
Status Location Address State License Number Phone
ACTIVE

23 FREELAND LANE

PALM COAST, FL 32137

RF11067823 (Exp: 08/31/2027) 386-569-4336
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/15/2026 FINAL APPROVED MCONTRYMAN
Note: 4/10/2026 - PREVIOUS INSPECTION NOTES 4/10/26 1. Garage lights need a proper box extension and sealed FBC EC TABLE R402.4.1.1 2. All soffit vents require solid soffit 6' from center of vent M1506.3 3. Seal up lv wire penetration by meter/main FBC 402.5.1.1 Both side: 4. Fridge required to be GFCi or ARc Fault protected NEC 210.12 5. Float switch on drain pan missing 6. Insulation for AH lines needs to be taped to wrap completely around the piping FBCR M1411.6 7. Heat Strips not labeled for AH units FBCR M1303.1 8. Missing termite sticker on panel boxes FBC R105.11 Side A: 9. Light not working above master bath sink FBC(A) 110.1 Side b: 10. Front exterior outlet box loose from wall 11. Right side frame of SGD loose from wall
SEWER TIE IN 04/10/2026 APPROVED MCONTRYMAN
Note: 4/9/2026 - PREVIOUS INSPECTION NOTES Cancelled via text at 1059am 4/2/2026 - PREVIOUS INSPECTION NOTES 4/2/26 1. Will need to dig up sewer tie-in for inspection or have it scoped. If scoped, try to schedule for inspection to be completed at the same time
BLD - BUILDING FINAL 04/10/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 4/10/26 1. Garage lights need a proper box extension and sealed FBC EC TABLE R402.4.1.1 2. All soffit vents require solid soffit 6' from center of vent M1506.3 3. Seal up lv wire penetration by meter/main FBC 402.5.1.1 Both side: 4. Fridge required to be GFCi or ARc Fault protected NEC 210.12 5. Float switch on drain pan missing 6. Insulation for AH lines needs to be taped to wrap completely around the piping FBCR M1411.6 7. Heat Strips not labeled for AH units FBCR M1303.1 8. Missing termite sticker on panel boxes FBC R105.11 Side A: 9. Light not working above master bath sink FBC(A) 110.1 Side b: 10. Front exterior outlet box loose from wall 11. Right side frame of SGD loose from wall
SEWER TIE IN 04/09/2026 CANCELLED BY APPLICANT MCONTRYMAN
Note: Cancelled via text at 1059am 4/2/2026 - PREVIOUS INSPECTION NOTES 4/2/26 1. Will need to dig up sewer tie-in for inspection or have it scoped. If scoped, try to schedule for inspection to be completed at the same time
ROW - FINAL INSPECTION 04/06/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 04/02/2026 APPROVED BVEIGA
Note: Inspector Notes from Inspection 9035 no/cc no/ irrigation
U-CROSS CONNECTION 04/02/2026 APPROVED - AS NOTED BVEIGA
Note: no/cc no/ irrigation
ROW - FINAL APRON (AFTER POUR) 04/02/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
FIREWALL FINAL 04/02/2026 Disapproved - NO FEE MCONTRYMAN
Note: 4/2/26 1. House is locked up so no access for an inspection FBC[A] 110.5
FIREWALL FINAL 04/02/2026 APPROVED MCONTRYMAN
Note: 4/2/2026 - PREVIOUS INSPECTION NOTES 4/2/26 1. House is locked up so no access for an inspection FBC[A] 110.5
ROW - FINAL INSPECTION 04/02/2026 CANCELLED BY APPLICANT EMADISON
Note: ** 04/02/26 CANCELLED ON-SITE BY BUILDER
SEWER TIE IN 04/02/2026 Disapproved - NO FEE MCONTRYMAN
Note: 4/2/26 1. Will need to dig up sewer tie-in for inspection or have it scoped. If scoped, try to schedule for inspection to be completed at the same time
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/01/2026 APPROVED - AS NOTED TPOLACEK
Note: 04-01-26 TPOLACEK*** AS PER PREVIOUS NOTES I WILL BE APPROVING THE FINAL SURVEY AS NOTED. 3/25/26 Gabe and I met with contractor about the final survey and the grading of this lot. We are going to allow the grading to be flat in the middle of the lot the drain to the right and the left drainage pattern. Any questions please contact Gabe or Parren -------------------------------------------------------------------------------------------- 2/25/2026 - PREVIOUS INSPECTION NOTES 02-25-26 TPOLACEK*** THERE IS NOT THE REQUIRED 6" OF FALL IN THE FIRST 10' OFF THE STRUCTURE IN THE REAR. THERE MUST BE POSITIVE FLOW FROM THE REAR TO FRONT SWALE. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 2/23/2026 - PREVIOUS INSPECTION NOTES ** 02/23/26 INSPECTOR IS REQUESTING MORE ELEVATION SHOTS IN REAR
ROW FIELD SURVEY /GRADING CERTIFICATION 04/01/2026 CANCELLED BY INSPECTOR TPOLACEK
Note: Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types Inspector Notes from Inspection 9463 04-01-26 TPOLACEK*** AS PER PREVIOUS NOTES I WILL BE APPROVING THE FINAL SURVEY AS NOTED. 3/25/26 Gabe and I met with contractor about the final survey and the grading of this lot. We are going to allow the grading to be flat in the middle of the lot the drain to the right and the left drainage pattern. Any questions please contact Gabe or Parren -------------------------------------------------------------------------------------------- 2/25/2026 - PREVIOUS INSPECTION NOTES 02-25-26 TPOLACEK*** THERE IS NOT THE REQUIRED 6" OF FALL IN THE FIRST 10' OFF THE STRUCTURE IN THE REAR. THERE MUST BE POSITIVE FLOW FROM THE REAR TO FRONT SWALE. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 2/23/2026 - PREVIOUS INSPECTION NOTES ** 02/23/26 INSPECTOR IS REQUESTING MORE ELEVATION SHOTS IN REAR
ROW- PROJECT STATUS 03/25/2026 Status Check PFLANAGAN
Note: Gabe and I met with contractor about the final survey and the grading of this lot. We are going to allow the grading to be flat in the middle of the lot the drain to the right and the left drainage pattern. Any questions please contact Gabe or Parren
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/25/2026 Disapproved - NO FEE TPOLACEK
Note: 02-25-26 TPOLACEK*** THERE IS NOT THE REQUIRED 6" OF FALL IN THE FIRST 10' OFF THE STRUCTURE IN THE REAR. THERE MUST BE POSITIVE FLOW FROM THE REAR TO FRONT SWALE. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 2/23/2026 - PREVIOUS INSPECTION NOTES ** 02/23/26 INSPECTOR IS REQUESTING MORE ELEVATION SHOTS IN REAR
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/23/2026 Disapproved - NO FEE EMADISON
Note: ** 02/23/26 INSPECTOR IS REQUESTING MORE ELEVATION SHOTS IN REAR
ELECTRIC - EARLY POWER 02/11/2026 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 9:50am
ELECTRIC - EARLY POWER 02/10/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Missing 2 front portch outlets
ROW- PRE-APRON (PRE-POUR) 01/07/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR 1/6/2026 - PREVIOUS INSPECTION NOTES 01-06-26 TPOLACEK*** CULVERT PIPES ARE BOTH OUT OF TOLERENCE. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 01/06/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 01-06-26 TPOLACEK*** CULVERT PIPES ARE BOTH OUT OF TOLERENCE. 2 Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
U - SEWER TIE IN 12/22/2025 APPROVED HCAMACHO
GRAVITY SEWER TEST 12/22/2025 APPROVED HCAMACHO
FIREWALL DRYWALL NAILING 10/24/2025 APPROVED MCONTRYMAN
Note: 10/15/2025 - PREVIOUS INSPECTION NOTES Covered porches need to be covered with 5/8 Type X Per Plan. Do not tape. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R702.3.5-wall 1/2 " gypsum board 24"space framing , 12"space for screws center to center on panels GYPSUM BOARD PANELS NEED TO BE PROPER INSTALL PLEASE SEE FLORIDA BUILDINGCODE FOR INSTRUCCTIONS #2-FBC 3303.5-SWALE CLEAR 9 REMOVED PORTA POTTY ) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4- PERMIT BOX NEED TO BE ON CONSTRUCTION PROPERTY #5-FBC 3307.1 -NEEDS SILT FENCE PROPERLY INSTALLED
FIREWALL DRYWALL NAILING 10/15/2025 PARTIALLY APPROVED HCAMACHO
Note: Covered porches need to be covered with 5/8 Type X Per Plan. Do not tape. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R702.3.5-wall 1/2 " gypsum board 24"space framing , 12"space for screws center to center on panels GYPSUM BOARD PANELS NEED TO BE PROPER INSTALL PLEASE SEE FLORIDA BUILDINGCODE FOR INSTRUCCTIONS #2-FBC 3303.5-SWALE CLEAR 9 REMOVED PORTA POTTY ) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4- PERMIT BOX NEED TO BE ON CONSTRUCTION PROPERTY #5-FBC 3307.1 -NEEDS SILT FENCE PROPERLY INSTALLED
INSULATION 10/06/2025 APPROVED HCAMACHO
Note: 10/3/2025 - PREVIOUS INSPECTION NOTES side A: 1. Please seal steel sleeve at end. 2. Master bath exhaust fan assembly is not wired. side B: 1. Please seal steel sleeve at end. 2. Added Light fixture in spare bath is not secured to truss members, and is not wired. 3. Missing Insulation at fire wall, by SGD. Inspector Notes from Inspection 2440 The ceiling is the fire wall/ framing. The center wall is just a draft stop, wich has 1/2 drywall installed front to back. Inspector Notes from Inspection 2420 1. Please revise the Product approval for the windows amd slider. 2. Please submitt letter for the wall overhanging. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- firewall framing need to add studs , see firewall plans for details
INSULATION 10/03/2025 Disapproved - NO FEE JSTEWART
Note: side A: 1. Please seal steel sleeve at end. 2. Master bath exhaust fan assembly is not wired. side B: 1. Please seal steel sleeve at end. 2. Added Light fixture in spare bath is not secured to truss members, and is not wired. 3. Missing Insulation at fire wall, by SGD. Inspector Notes from Inspection 2440 The ceiling is the fire wall/ framing. The center wall is just a draft stop, wich has 1/2 drywall installed front to back. Inspector Notes from Inspection 2420 1. Please revise the Product approval for the windows amd slider. 2. Please submitt letter for the wall overhanging. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- firewall framing need to add studs , see firewall plans for details
LATH/BRICK/ WATER BARRIER 10/02/2025 APPROVED - AS NOTED HCAMACHO
Note: Inspector Notes from Inspection 2440 The ceiling is the fire wall/ framing. The center wall is just a draft stop, wich has 1/2 drywall installed front to back. Inspector Notes from Inspection 2420 1. Please revise the Product approval for the windows amd slider. 2. Please submitt letter for the wall overhanging. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- firewall framing need to add studs , see firewall plans for details
ALL ROUGH 09/29/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Please revise the Product approval for the windows amd slider. 2. Please submitt letter for the wall overhanging. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door.
FIREWALL FRAMING 09/29/2025 APPROVED - AS NOTED HCAMACHO
Note: The ceiling is the fire wall/ framing. The center wall is just a draft stop, wich has 1/2 drywall installed front to back. Inspector Notes from Inspection 2420 1. Please revise the Product approval for the windows amd slider. 2. Please submitt letter for the wall overhanging. 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door. 8/21/2025 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- firewall framing need to add studs , see firewall plans for details
ALL ROUGH 09/23/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 9/23/25 Make all repairs before calling in re-inspection, items 2, 3, 4, and 5 not complete, Also missing pancake boxes on front of garages for lights as well as load bearing wall in garage is over hanging slab which requires a proper repair. Please make all repairs before calling in re-inspection 8/26/25 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door.
ALL ROUGH 08/26/2025 Disapproved -FEE REQUIRED HCAMACHO
Note: 1. The location of the A/C appliance in the attic does not meet code. FBCR M1305.1.3 SERVICE PLATFORM IN ATTIC 2. A/C contractor still running the copper lines and electric on the left side. FBC [A]107.4 3. Need fire blocking on the wall where the fireplace sits.FBC R302.11.1 4. No paper work on the windows and doors for inspection.FBC [A]107.4 5. The draft stop wall is not finished. Missing framing, nailing, and it needs to go all the way to the front porch.FBCR 302.12 6. Missing house to garage door.
FIREWALL DRYWALL NAILING 08/21/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC-R702.3.5-wall 1/2 " gypsum board 24"space framing , 12"space for screws center to center on panels GYPSUM BOARD PANELS NEED TO BE PROPER INSTALL PLEASE SEE FLORIDA BUILDINGCODE FOR INSTRUCCTIONS #2-FBC 3303.5-SWALE CLEAR 9 REMOVED PORTA POTTY ) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4- PERMIT BOX NEED TO BE ON CONSTRUCTION PROPERTY #5-FBC 3307.1 -NEEDS SILT FENCE PROPERLY INSTALLED
FIREWALL FRAMING 08/21/2025 APPROVED CVANSTRAHLEN
FIREWALL FRAMING 08/21/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix item before next inspection #1- firewall framing need to add studs , see firewall plans for details
ROOF VALLEY & METAL 08/07/2025 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/05/2025 APPROVED FWILLIS
Note: *** NOTES ADDED BY FWILLIS 8/5/2025 10:48:36 AM *** ITEMS CORRECTED 8/1/2025 - PREVIOUS INSPECTION NOTES 1. A01 truss on the block wall on side B is missing HETA20. 2. D04(4) trussboth sides is missing anchors at door frame in garage and the straps on the block wall over the front door are not anchored. 3. D03A truss both sides are missing straps on block wall at front entrance. 4. House to Garage door framing is not framed out according to plans. This is a bearing wall. See plans detail. Both sides. 5. Gable trusses over garages and front entry are missing bracing. See plans for detail. 6. Bearing wall studs and top plates are notched more then 40% by plumbing.
WALL SHEATHING 08/01/2025 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/01/2025 Disapproved -FEE REQUIRED HCAMACHO
Note: 1. A01 truss on the block wall on side B is missing HETA20. 2. D04(4) trussboth sides is missing anchors at door frame in garage and the straps on the block wall over the front door are not anchored. 3. D03A truss both sides are missing straps on block wall at front entrance. 4. House to Garage door framing is not framed out according to plans. This is a bearing wall. See plans detail. Both sides. 5. Gable trusses over garages and front entry are missing bracing. See plans for detail. 6. Bearing wall studs and top plates are notched more then 40% by plumbing.
TIE BEAM / LINTEL 07/11/2025 APPROVED KSANDOE
Note: 7/9/2025 - PREVIOUS INSPECTION NOTES 1. Missing 1 dowel in the left garage front. The dowel that is there is in the wrong place. Marked.FBC [A]107.4 2. Missing 1 dowel in the rear right bathroom window. Marked.FBC [A]107.4
TIE BEAM / LINTEL 07/09/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Missing 1 dowel in the left garage front. The dowel that is there is in the wrong place. Marked.FBC [A]107.4 2. Missing 1 dowel in the rear right bathroom window. Marked.FBC [A]107.4
MONOLITHIC SLAB 06/20/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Clean up swale, allot of garbage in the swale. FBC 3303.5 SWALE CLEAR
PLUMBING 1ST ROUGH UNDERGROUND 06/13/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/12/2025 APPROVED JMUNSON
FORMBOARD SURVEY (OFFICE USE ONLY) 06/10/2025 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 05/09/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SWALE COMPLETE 12/29/2025 12/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 10/02/2025 10/07/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 08/18/2025 08/18/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 06/12/2025 06/12/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 06/09/2025 06/09/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
CUSVC COMPLETE 04/09/2025 04/09/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
SW1 COMPLETE 04/03/2025 04/09/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/03/2025 04/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
MECH COMPLETE 04/03/2025 04/08/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/03/2025 04/07/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 04/03/2025 04/03/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
PLENV COMPLETE 03/25/2025 04/01/2025
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 04/01/2025 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
ZON HOLD 03/20/2025 03/24/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM site plan: Each side of the driveway should be a min of 16' adjust plans accordingly Elevation plan: doesnt match the site plan electric plan doesnt match any of the plans plans, provide a floor plan All plans dont match please submit the correct plans could not review properly as non of the plans match
SW1 COMPLETE 03/20/2025 03/25/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
MECH HOLD 03/20/2025 03/25/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Duct layout signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
LOCATE COMPLETE 03/20/2025 03/25/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
GAS CANCEL 03/20/2025 03/25/2025
ENGIN1 COMPLETE 03/20/2025 03/20/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ELEC COMPLETE 03/20/2025 03/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 03/20/2025 03/24/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
BLD HOLD 03/20/2025 03/26/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Worksheet 1. FL# 10124-R25 out of cycle. We are in the 2023 code cycle. 2. FL# 10626-R23 out of cycle.
BADMIN COMPLETE 03/20/2025 03/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SWALE COMPLETE 03/20/2025 04/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 04/15/2026
RSI GENERAL INSPECTION 32.50 ¤32.50 04/01/2026
RSI REINSPECTION 1 ¤35.00 04/01/2026
PLAN REVIEW - REVISION ¤32.50 04/01/2026
REINSPECTION RESIDENTIAL ¤40.00 04/01/2026
REINSPECTION RESIDENTIAL ¤40.00 04/01/2026
REINSPECTION RESIDENTIAL ¤40.00 04/01/2026
REINSPECTION RESIDENTIAL ¤40.00 08/18/2025
CONTRACTOR CHANGE ¤20.00 08/18/2025
CONTRACTOR CHANGE ¤20.00 08/18/2025
CONTRACTOR CHANGE ¤20.00 05/05/2025
CONTRACTOR CHANGE ¤20.00 05/05/2025
CONNECTION FEES ¤2,374.52 05/05/2025
SURCHARGE FS 533.721 ¤17.36 05/05/2025
SURCHARGE - FS 468.631 ¤26.04 05/05/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/05/2025
SW ENG INSPECTION 80 ¤80.00 05/05/2025
SW ENG PRE APRON ¤30.00 05/05/2025
SW ENG - REVIEW 20 ¤20.00 05/05/2025
SW ENG RES REVIEW 200 ¤200.00 05/05/2025
SEWER CREDIT (¤4,782.75) 05/05/2025
SEWER INSPECTION ¤25.00 05/05/2025
SEWER CAPITAL FACILITY ¤12,241.04 05/05/2025
WATER CAPITAL FACILITY FEE ¤8,702.28 05/05/2025
SITE PLAN 30 ¤30.00 05/05/2025
FC IMPACT FEE EMS ¤124.00 05/05/2025
IMPACT FEE FIRE ¤869.02 05/05/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 05/05/2025
FC IMPACT FEE LIBRARY ¤536.00 05/05/2025
IMPACT FEE PARKS ¤3,656.02 05/05/2025
IMPACT FEE SCHOOL ¤10,900.00 05/05/2025
IMPACT FEE TRANSPORTATION ¤7,004.00 05/05/2025
WATER -IRRIGATION INSPECTION ¤50.00 05/05/2025
WATER- TURN ON ¤50.00 05/05/2025
ADJUSTMENT 10% (¤192.91) 05/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/05/2025
INSPECTION - RESIDENTIAL ¤1,479.50 05/05/2025
PLAN REVIEW - RESIDENTIAL ¤419.64 05/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤44,724.76