I want to search for...
Permit #2025031194
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7032-00740-0130 |
| Block: 00740 |
| Subdivision: 7032 - |
| Job Phone: 352-430-8703 |
| Location Address: 14 ROLLINS LN |
| Type: RF - REROOF |
| Issue Date: 03/28/2025 |
| NOC: RECORDED |
| Applicant name: DAVID WALTER FLETCHER |
| Owner: SOWINSKI PAUL A & THERESA K H&W |
|
Address 5901 FIRE LANE RHINELANDER, WI 54501 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤34,000.00 |
| Job Description: REROOF |
| Type: CN |
Contractor
DSM ROOFING LLC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
56107 HYACINTH ROAD ASTOR, FL 32102 |
CCC1327783 (Exp: 08/31/2026) | (352)759-9925 | (352)759-9925 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF IN PROGRESS- MIDROOF | 04/08/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Need engineering latter or cerificated for roofing deck 4/7/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications | |||
| ROOF IN PROGRESS- MIDROOF | 04/07/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications | |||
| ROOF SHEATHING | 04/02/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: need working sheet on side with especification for material and applications | |||
| ROOF IN PROGRESS- MIDROOF | 04/02/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: need working sheet on side with especification for material and applications | |||
| ROOF AFFIDAVIT | |||
| ROOF SHEATHING | |||
| Note: 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications | |||
| ROOF IN PROGRESS- MIDROOF | |||
| Note: 4/8/2025 - PREVIOUS INSPECTION NOTES Need engineering latter or cerificated for roofing deck 4/7/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications | |||
| ROOF FINAL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤12.35) | 03/28/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/28/2025 |
| INSPECTION - RESIDENTIAL | ¤93.50 | 03/28/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/28/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/28/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤115.15 |