I want to search for...

Permit #2025031194

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7032-00740-0130
Block: 00740
Subdivision: 7032 -
Job Phone: 352-430-8703
Location Address: 14 ROLLINS LN
Type: RF - REROOF
Issue Date: 03/28/2025
NOC: RECORDED
Applicant name: DAVID WALTER FLETCHER
Owner: SOWINSKI PAUL A & THERESA K H&W

Address

5901 FIRE LANE

RHINELANDER, WI 54501

Lot: 0130
Contracted Stated Job Value: ¤34,000.00
Job Description: REROOF
Type: CN

Contractor

DSM ROOFING LLC
Status Location Address State License Number Phone Fax
INACTIVE

56107 HYACINTH ROAD

ASTOR, FL 32102

CCC1327783 (Exp: 08/31/2026) (352)759-9925 (352)759-9925

Inspection History

Type Request Date Result Inspector
ROOF IN PROGRESS- MIDROOF 04/08/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Need engineering latter or cerificated for roofing deck 4/7/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications
ROOF IN PROGRESS- MIDROOF 04/07/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications
ROOF SHEATHING 04/02/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: need working sheet on side with especification for material and applications
ROOF IN PROGRESS- MIDROOF 04/02/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: need working sheet on side with especification for material and applications
ROOF AFFIDAVIT
ROOF SHEATHING
Note: 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications
ROOF IN PROGRESS- MIDROOF
Note: 4/8/2025 - PREVIOUS INSPECTION NOTES Need engineering latter or cerificated for roofing deck 4/7/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- missing roof seathing inspection #2- by DBPR factory code can't install metal roof over shingles , need to removed all metal roof , underlyment ans shingles to inspected roof deck DBPR -6. Wood Deck shall be designed by others in accordance with FBC requirements. 15/32 CDX plywood shall be minimum 15/32-inch thick, PS 1-19 Grade C-D, Exposure 1, APA Span-Rated plywood sheathing at maximum 24-inch span. 7/16 Oriented Strand Board (OSB) sheathing shall be minimum 7/16- inch thick, PS 2-18, APA Span-Rated, Exposure 1, OSB sheathing at maximum 24-inch span. 7. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the ea 4/2/2025 - PREVIOUS INSPECTION NOTES need working sheet on side with especification for material and applications
ROOF FINAL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.35) 03/28/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/28/2025
INSPECTION - RESIDENTIAL ¤93.50 03/28/2025
SURCHARGE FS 533.721 ¤2.00 03/28/2025
SURCHARGE - FS 468.631 ¤2.00 03/28/2025
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤115.15