I want to search for...
Permit #2025031222
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00070-0380 |
| GARAGE: 437 sqft |
| OPENED PORCH (WITH ROOF) : 182 sqft |
| OPENED PORCH (WITH ROOF) : 89 sqft |
| CONDITIONED SPACE: 1754 sqft |
| Total Square Footage: 2462 sqft |
| Block: 00070 |
| Subdivision: - |
| Job Phone: 407-476-8195 |
| Location Address: 31 BURNING VIEW LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/25/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LLC |
|
Address 3670 MAGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address SUITE 220 ORLANDO, FL 32803 |
| Lot: 0380 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/26/2026 | FINAL APPROVED | HCAMACHO |
| Note: 5/20/2026 - PREVIOUS INSPECTION NOTES 5/20/26 1. No paperwork on site for inspection FBC(A) 107.3.1 2. Multiple windows need adjustment. Will not line up properly to lock 3. Back right bedroom, right wall outlet; top of receptacle not working 4. Seal up top, front wall, above garage door. Can see daylight FBC 402.5.1.1 5. Kitchen outlets have no power NEC 210.8 | |||
| BLD - BUILDING FINAL | 05/20/2026 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 5/20/26 1. No paperwork on site for inspection FBC(A) 107.3.1 2. Multiple windows need adjustment. Will not line up properly to lock 3. Back right bedroom, right wall outlet; top of receptacle not working 4. Seal up top, front wall, above garage door. Can see daylight FBC 402.5.1.1 5. Kitchen outlets have no power NEC 210.8 | |||
| U -UTILITY RESIDENTIAL FINAL | 05/20/2026 | APPROVED | TLOWE |
| Note: Inspector Notes from Inspection 9035 NO/CC NO IRR | |||
| ROW - FINAL APRON (AFTER POUR) | 05/18/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/18/2026 | CANCELLED BY INSPECTOR | TPOLACEK |
| Note: BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types | |||
| ROW - STORMWATER FINAL | 05/18/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/14/2026 | APPROVED | EMADISON |
| Note: | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/08/2026 | Disapproved - NO FEE | EMADISON |
| Note: ** 05/08/26 10 FT OFFSET SHOTS ARE REQUIRED ON ALL ADJACENT PROPERTIES YOU HAVE NO OFFSET SHOTS ** 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Section 300.01 B(3) V-15 | |||
| U-CROSS CONNECTION | 05/07/2026 | APPROVED - AS NOTED | BVEIGA |
| Note: NO/CC NO IRR | |||
| ROW- PRE-APRON (PRE-POUR) | 04/06/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 04/06/26 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300, E RESIDENTIAL CULVERT DETAIL _________________________________________________________________________________________________________________________ 4/2/2026 - PREVIOUS INSPECTION NOTES ** 04/02/26 CANCELLED VIA PHONE CALL FROM TYLER WITH INB SITE NOT READY FOR INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 04/02/2026 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 04/02/26 CANCELLED VIA PHONE CALL FROM TYLER WITH INB SITE NOT READY FOR INSPECTION | |||
| ELECTRIC - EARLY POWER | 03/03/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2200 Authorize release of email. | |||
| GRAVITY SEWER TEST | 02/12/2026 | APPROVED | MCONTRYMAN |
| SEWER TIE IN | 02/12/2026 | APPROVED | MCONTRYMAN |
| PEP TANK INSTALLATION REQUEST | 02/05/2026 | APPROVED | CBOWERMASTER |
| INSULATION | 02/04/2026 | APPROVED | JSTEWART |
| Note: 2/3/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified.....1. Header box built in laundry room needs to be fire foamed around ceiling edges and and vent pipe FBCR 302.11 (Vent pipe Penetration thru the top of soffit into attic requires the annular space to be sealed (fire foam). 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 1. Header box built in laundry room needs to be fire foamed around ceiling edges and and vent pipe FBCR 302.11 2. Missinf foam around AH ceiling penetrations FBCR 302.11 3. Unused opening missing fire foam on shared wall with master BR and Master closet FBCR 302.11 4. Empty cavity behing front entry door needs fire foamed around ceiling edges FBCR 302.11 Inspector Notes from Inspection 2420 1/22/26 1. Duct layout does not match what is installed. Please have revised and approved layout by next inspection FBC(A) 107.4 2. Twisted studs in front entry way, left side wall 3. Broken window in guest bath 1/20/2026 - PREVIOUS INSPECTION NOTES 1/20/26: INCOMPLETE INSPECTION due to missing documents, etc. 1). Missing Energy calcs and FPA sheet in permit box laying on the ground. FBC [A]107.3.1 2). No address. FBCR 319.1 3). Could not inspect windows due to stucco in progress. FBC [A]107.4 4). 5ft head pressure not holding. FBC-P2503.5.1 NOTE: A full inspection will be required. | |||
| INSULATION | 02/03/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Note not rectified.....1. Header box built in laundry room needs to be fire foamed around ceiling edges and and vent pipe FBCR 302.11 (Vent pipe Penetration thru the top of soffit into attic requires the annular space to be sealed (fire foam). 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 1. Header box built in laundry room needs to be fire foamed around ceiling edges and and vent pipe FBCR 302.11 2. Missinf foam around AH ceiling penetrations FBCR 302.11 3. Unused opening missing fire foam on shared wall with master BR and Master closet FBCR 302.11 4. Empty cavity behing front entry door needs fire foamed around ceiling edges FBCR 302.11 Inspector Notes from Inspection 2420 1/22/26 1. Duct layout does not match what is installed. Please have revised and approved layout by next inspection FBC(A) 107.4 2. Twisted studs in front entry way, left side wall 3. Broken window in guest bath 1/20/2026 - PREVIOUS INSPECTION NOTES 1/20/26: INCOMPLETE INSPECTION due to missing documents, etc. 1). Missing Energy calcs and FPA sheet in permit box laying on the ground. FBC [A]107.3.1 2). No address. FBCR 319.1 3). Could not inspect windows due to stucco in progress. FBC [A]107.4 4). 5ft head pressure not holding. FBC-P2503.5.1 NOTE: A full inspection will be required. | |||
| INSULATION | 02/02/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 2/2/26 1. Header box built in laundry room needs to be fire foamed around ceiling edges and and vent pipe FBCR 302.11 2. Missinf foam around AH ceiling penetrations FBCR 302.11 3. Unused opening missing fire foam on shared wall with master BR and Master closet FBCR 302.11 4. Empty cavity behing front entry door needs fire foamed around ceiling edges FBCR 302.11 Inspector Notes from Inspection 2420 1/22/26 1. Duct layout does not match what is installed. Please have revised and approved layout by next inspection FBC(A) 107.4 2. Twisted studs in front entry way, left side wall 3. Broken window in guest bath 1/20/2026 - PREVIOUS INSPECTION NOTES 1/20/26: INCOMPLETE INSPECTION due to missing documents, etc. 1). Missing Energy calcs and FPA sheet in permit box laying on the ground. FBC [A]107.3.1 2). No address. FBCR 319.1 3). Could not inspect windows due to stucco in progress. FBC [A]107.4 4). 5ft head pressure not holding. FBC-P2503.5.1 NOTE: A full inspection will be required. | |||
| ALL ROUGH | 01/22/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 1/22/26 1. Duct layout does not match what is installed. Please have revised and approved layout by next inspection FBC(A) 107.4 2. Twisted studs in front entry way, left side wall 3. Broken window in guest bath 1/20/2026 - PREVIOUS INSPECTION NOTES 1/20/26: INCOMPLETE INSPECTION due to missing documents, etc. 1). Missing Energy calcs and FPA sheet in permit box laying on the ground. FBC [A]107.3.1 2). No address. FBCR 319.1 3). Could not inspect windows due to stucco in progress. FBC [A]107.4 4). 5ft head pressure not holding. FBC-P2503.5.1 NOTE: A full inspection will be required. | |||
| ALL ROUGH | 01/20/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/20/2026 1:33:43 PM *** 1/20/26: INCOMPLETE INSPECTION due to missing documents, etc. 1). Missing Energy calcs and FPA sheet in permit box laying on the ground. FBC [A]107.3.1 2). No address. FBCR 319.1 3). Could not inspect windows due to stucco in progress. FBC [A]107.4 4). 5ft head pressure not holding. FBC-P2503.5.1 NOTE: A full inspection will be required. | |||
| LATH/BRICK/ WATER BARRIER | 01/16/2026 | APPROVED | JSTEWART |
| ELECTRIC-TUG | 01/08/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| ROOF VALLEY & METAL | 01/07/2026 | APPROVED | MCONTRYMAN |
| WALL SHEATHING | 12/30/2025 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/30/2025 | APPROVED | JSTEWART |
| ROOF SHEATHING | 12/30/2025 | CANCELLED BY INSPECTOR | JSTEWART |
| Note: Not needed. | |||
| TIE BEAM / LINTEL | 12/16/2025 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 12/05/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Notes not fully rectified........all column support pads reinforcement require 3" from soil (bottom,top,sides) FBC R404.1.3.3.7.4 12/4/2025 - PREVIOUS INSPECTION NOTES footing reinforcement thru out does not meet the required MIN 3" clearence from soil. Spots where reinforcement is laying directly on soil. FBC R404.1.3.3.7.4 | |||
| MONOLITHIC SLAB | 12/05/2025 | APPROVED | JSTEWART |
| Note: 12/5/2025 - PREVIOUS INSPECTION NOTES Previous Notes not fully rectified........all column support pads reinforcement require 3" from soil (bottom,top,sides) FBC R404.1.3.3.7.4 12/4/2025 - PREVIOUS INSPECTION NOTES footing reinforcement thru out does not meet the required MIN 3" clearence from soil. Spots where reinforcement is laying directly on soil. FBC R404.1.3.3.7.4 | |||
| MONOLITHIC SLAB | 12/04/2025 | Disapproved - NO FEE | JSTEWART |
| Note: footing reinforcement thru out does not meet the required MIN 3" clearence from soil. Spots where reinforcement is laying directly on soil. FBC R404.1.3.3.7.4 | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 11/21/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/20/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/13/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 10/22/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | HOLD | 11/20/2025 | 11/20/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The dimension along the front of the property 17.35 does not match the approved grading plan. | |||
| ZON | COMPLETE | 11/20/2025 | 11/20/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/20/2025 | 11/21/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/20/2025 | 11/21/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/20/2025 | 11/21/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Had to reject submitted site plan and re up load the revised site plan in order to stamp it | |||
| BLD | COMPLETE | 11/13/2025 | 11/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/21/2025 | 10/22/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/08/2025 | 10/09/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on the energy calcs and heatload need to be Daytona Beach | |||
| MECH | COMPLETE | 04/02/2025 | 04/04/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/01/2025 | 04/01/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/28/2025 | 04/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/27/2025 | 03/31/2025 |
| LOCATE | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/27/2025 | 03/31/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy calcs and state card from wrong address | |||
| SW1 | HOLD | 03/27/2025 | 03/31/2025 |
| Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Per COPC Technical Manual, there shall be a minimum of 0.3' fall from the top of the swale to the toe of slope along the property lines. | |||
| ZON | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/20/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 04/10/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 09/25/2025 |
| IMPACT FEE FIRE | ¤434.51 | 09/25/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/25/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/25/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 09/25/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/25/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 09/25/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/25/2025 |
| SURCHARGE FS 533.721 | ¤11.07 | 09/25/2025 |
| SURCHARGE - FS 468.631 | ¤16.61 | 09/25/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/25/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/25/2025 |
| SW ENG PRE APRON | ¤30.00 | 09/25/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/25/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/25/2025 |
| SEWER CREDIT | (¤2,465.75) | 09/25/2025 |
| SEWER INSPECTION | ¤25.00 | 09/25/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 09/25/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 09/25/2025 |
| SITE PLAN 30 | ¤30.00 | 09/25/2025 |
| WATER- TURN ON | ¤25.00 | 09/25/2025 |
| ADJUSTMENT 10% | (¤123.02) | 09/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/25/2025 |
| INSPECTION - RESIDENTIAL | ¤935.00 | 09/25/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤265.20 | 09/25/2025 |
| CONNECTION FEES | ¤1,187.26 | 09/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,172.05 |