I want to search for...
Permit #2025031223
Permit Details
Status: COED
| Parcel Id: 07-11-31-7032-00500-0350 |
| CONDITIONED SPACE: 1754 sqft |
| GARAGE: 651 sqft |
| OPENED PORCH (WITH ROOF) : 182 sqft |
| OPENED PORCH (WITH ROOF) : 89 sqft |
| Total Square Footage: 2676 sqft |
| Block: 00500 |
| Subdivision: - |
| Job Phone: 407-476-8195 |
| Location Address: 33 ROXANNE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/25/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LLC |
|
Address 3670 MAGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address STE 220 ORLANDO, FL 32803 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/25/2026 | APPROVED | CVANSTRAHLEN |
| Note: 3/13/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #2-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) mechanical room #3-Front door and garage door missing weather stripping #4-AH need locking breaker per florida code Specs -NEC.422.31-Disconnection of permanently connected Appliance-the brand circuit overcurrent device shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from the appliance or been capable of been locked in the open position in compliance with 110.25 #5-Small garage door do not work properly ( sensor dont work , door do not stop ) #6- electrical fan round box uncovert about garage motor #7-5. Seal up soffit penetrations for electrical mast | |||
| BLD - BUILDING FINAL | 03/13/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 3/13/2026 12:35:47 PM *** Please install pantry door Please fix items before next inspection #1-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #2-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) mechanical room #3-Front door and garage door missing weather stripping #4-AH need locking breaker per florida code Specs -NEC.422.31-Disconnection of permanently connected Appliance-the brand circuit overcurrent device shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from the appliance or been capable of been locked in the open position in compliance with 110.25 #5-Small garage door do not work properly ( sensor dont work , door do not stop ) #6- electrical fan round box uncovert about garage motor #7-5. Seal up soffit penetrations for electrical mast | |||
| ROW - STORMWATER FINAL | 03/13/2026 | APPROVED | FSLADISH |
| Note: 3/13/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ____________________________________________________________________________________________________________________________ *** INSPECTORS NOTE. SPOKE WITH FRANK CM AND HE SAID WOULD LOWER THE HIGH SPOT ON THE LEFT SIDE PAST THE PROPERTY LINE TO ESTABLISH POSITIVE DRAINAGE FLOW. OUTLINED IN PAINT. CHECK FOR COMPLETION BEFORE ROW FINAL PASSAGE. *** | |||
| U -UTILITY RESIDENTIAL FINAL | 03/13/2026 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No CC, No IRR. | |||
| ROW - FINAL APRON (AFTER POUR) | 03/06/2026 | APPROVED | FSLADISH |
| Note: 3/6/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/6/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. SPOKE WITH FRANK CM AND HE SAID WOULD LOWER THE HIGH SPOT ON THE LEFT SIDE PAST THE PROPERTY LINE TO ESTABLISH POSITIVE DRAINAGE FLOW. OUTLINED IN PAINT. CHECK FOR COMPLETION BEFORE ROW FINAL PASSAGE. *** | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/06/2026 | APPROVED | FSLADISH |
| Note: 2/24/2026 - PREVIOUS INSPECTION NOTES 2/24/26 LEFT SIDE DRAINAGE FLOW GOES FROM 33.80 AT LEFT REAR STRUCTURE CORNER TO 33.70 BACK UP TO 33.80, DRAINAGE WILL POOL HERE AND NOT HAVE POSITIVE FORWARD DRAINAGE FLOW. YOUR FRONT SWALE FLOWS RIGHT TO LEFT. COMING OUT OF THE LEFT SIDE CULVERT YOU COME FROM A 31.55 UPHILL TO 32.20 TO A 32.15 THEN THE INVERT ON THE LEFT ADJOINING PROPERTY IS 31.56 INDICATING THAT THERE WILL NOT BE POSITIVE SWALE DRAINAGE FLOW. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/06/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/6/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. SPOKE WITH FRANK CM AND HE SAID WOULD LOWER THE HIGH SPOT ON THE LEFT SIDE PAST THE PROPERTY LINE TO ESTABLISH POSITIVE DRAINAGE FLOW. OUTLINED IN PAINT. CHECK FOR COMPLETION BEFORE ROW FINAL PASSAGE. *** | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/24/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 2/24/26 LEFT SIDE DRAINAGE FLOW GOES FROM 33.80 AT LEFT REAR STRUCTURE CORNER TO 33.70 BACK UP TO 33.80, DRAINAGE WILL POOL HERE AND NOT HAVE POSITIVE FORWARD DRAINAGE FLOW. YOUR FRONT SWALE FLOWS RIGHT TO LEFT. COMING OUT OF THE LEFT SIDE CULVERT YOU COME FROM A 31.55 UPHILL TO 32.20 TO A 32.15 THEN THE INVERT ON THE LEFT ADJOINING PROPERTY IS 31.56 INDICATING THAT THERE WILL NOT BE POSITIVE SWALE DRAINAGE FLOW. REAR YARD DRAIAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan | |||
| U-CROSS CONNECTION | 02/20/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, No IRR. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/04/2026 | APPROVED | FSLADISH |
| Note: 2/4/26 ALL REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR,IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. _____________________________________________________________________________________________________________________________ 2/3/2026 - PREVIOUS INSPECTION NOTES ** 02/03/26 THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE WITHIN THE DRIVEWAY POUR AREA ABOVE THE RIGHT OF WAY (ROW) CURRENTLY MEASURING 3 INCHES AND UNDER IN MULTIPLE LOCATIONS ** DRIVEWAY CONCRETE THICKNESS OUTSIDE THE ROW MUST BE A MINIMUM OF 4"".Sec 300.E" ** REMOVE OVER POURED CONCRETE BETWEEN GARAGE DOOR OPENING ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________________ 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 RECEIVED TEXT FROM FRANKI CM TO PLEASE CANCEL FOR TODAY. 1/29/2026 - PREVIOUS INSPECTION NOTES 1/29/26 SPOKE WITH FRANK CM AND HE REQUESTED WE CANCEL THIS INSPECTION FOR TODAY. ___________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOUR RIGHT SIDE CULVERT PIPE MITERED END IS TO LONG. COPC STANDARD IS MINIMUN OF 6" FROM TOP CENTER OF MITER CUT TO MITERED END. 18" IS ACCEPTED STANDARD ON THE LONGEST LENGTH WE WOULD LIKE TO SEE AS STATED IT SHOULD BE EQUAL TO THE END OF THE APRON WING. YOURS IS APPROXIMATELY 36". YOU HAVE FORMBOARDS BROKED IN SEVERAL AREAS. THE LEFT SIDE MITERED END HAS ROOTS, TRASH AND DEBRIS IN THE POUR AREA. SEE PHOTO FOR REFERENCE AND DRAWING 300.E. ______________________________________________________________________________________________________________________________ 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| ROW- PRE-APRON (PRE-POUR) | 02/03/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 02/03/26 THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE WITHIN THE DRIVEWAY POUR AREA ABOVE THE RIGHT OF WAY (ROW) CURRENTLY MEASURING 3 INCHES AND UNDER IN MULTIPLE LOCATIONS ** DRIVEWAY CONCRETE THICKNESS OUTSIDE THE ROW MUST BE A MINIMUM OF 4"".Sec 300.E" ** REMOVE OVER POURED CONCRETE BETWEEN GARAGE DOOR OPENING ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________________ 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 RECEIVED TEXT FROM FRANKI CM TO PLEASE CANCEL FOR TODAY. 1/29/2026 - PREVIOUS INSPECTION NOTES 1/29/26 SPOKE WITH FRANK CM AND HE REQUESTED WE CANCEL THIS INSPECTION FOR TODAY. ___________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOUR RIGHT SIDE CULVERT PIPE MITERED END IS TO LONG. COPC STANDARD IS MINIMUN OF 6" FROM TOP CENTER OF MITER CUT TO MITERED END. 18" IS ACCEPTED STANDARD ON THE LONGEST LENGTH WE WOULD LIKE TO SEE AS STATED IT SHOULD BE EQUAL TO THE END OF THE APRON WING. YOURS IS APPROXIMATELY 36". YOU HAVE FORMBOARDS BROKED IN SEVERAL AREAS. THE LEFT SIDE MITERED END HAS ROOTS, TRASH AND DEBRIS IN THE POUR AREA. SEE PHOTO FOR REFERENCE AND DRAWING 300.E. ______________________________________________________________________________________________________________________________ 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| ROW- PRE-APRON (PRE-POUR) | 02/02/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 2/2/26 RECEIVED TEXT FROM FRANKI CM TO PLEASE CANCEL FOR TODAY. 1/29/2026 - PREVIOUS INSPECTION NOTES 1/29/26 SPOKE WITH FRANK CM AND HE REQUESTED WE CANCEL THIS INSPECTION FOR TODAY. ___________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOUR RIGHT SIDE CULVERT PIPE MITERED END IS TO LONG. COPC STANDARD IS MINIMUN OF 6" FROM TOP CENTER OF MITER CUT TO MITERED END. 18" IS ACCEPTED STANDARD ON THE LONGEST LENGTH WE WOULD LIKE TO SEE AS STATED IT SHOULD BE EQUAL TO THE END OF THE APRON WING. YOURS IS APPROXIMATELY 36". YOU HAVE FORMBOARDS BROKED IN SEVERAL AREAS. THE LEFT SIDE MITERED END HAS ROOTS, TRASH AND DEBRIS IN THE POUR AREA. SEE PHOTO FOR REFERENCE AND DRAWING 300.E. ______________________________________________________________________________________________________________________________ 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| ROW- PRE-APRON (PRE-POUR) | 01/29/2026 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 1/29/26 SPOKE WITH FRANK CM AND HE REQUESTED WE CANCEL THIS INSPECTION FOR TODAY. ___________________________________________________________________________________________________________________________ 1/27/2026 - PREVIOUS INSPECTION NOTES 1/27/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOUR RIGHT SIDE CULVERT PIPE MITERED END IS TO LONG. COPC STANDARD IS MINIMUN OF 6" FROM TOP CENTER OF MITER CUT TO MITERED END. 18" IS ACCEPTED STANDARD ON THE LONGEST LENGTH WE WOULD LIKE TO SEE AS STATED IT SHOULD BE EQUAL TO THE END OF THE APRON WING. YOURS IS APPROXIMATELY 36". YOU HAVE FORMBOARDS BROKED IN SEVERAL AREAS. THE LEFT SIDE MITERED END HAS ROOTS, TRASH AND DEBRIS IN THE POUR AREA. SEE PHOTO FOR REFERENCE AND DRAWING 300.E. ______________________________________________________________________________________________________________________________ 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| ROW- PRE-APRON (PRE-POUR) | 01/27/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 1/27/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOUR RIGHT SIDE CULVERT PIPE MITERED END IS TO LONG. COPC STANDARD IS MINIMUN OF 6" FROM TOP CENTER OF MITER CUT TO MITERED END. 18" IS ACCEPTED STANDARD ON THE LONGEST LENGTH WE WOULD LIKE TO SEE AS STATED IT SHOULD BE EQUAL TO THE END OF THE APRON WING. YOURS IS APPROXIMATELY 36". YOU HAVE FORMBOARDS BROKED IN SEVERAL AREAS. THE LEFT SIDE MITERED END HAS ROOTS, TRASH AND DEBRIS IN THE POUR AREA. SEE PHOTO FOR REFERENCE AND DRAWING 300.E. ______________________________________________________________________________________________________________________________ 1/23/2026 - PREVIOUS INSPECTION NOTES 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| ELECTRIC - EARLY POWER | 01/27/2026 | APPROVED | CVANSTRAHLEN |
| ROW- PRE-APRON (PRE-POUR) | 01/23/2026 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 01-23-26 TPOLACEK*** CULVERT SHOULD BE CENTERED IN DRIVEWAY, CULVERT ENDS SHOULD BE EQUAL TO THE WIDTH OF DRIVEWAY AT ROAD EDGE AS SHOWN IN 300G ATTACHED TO PERMIT PHOTOS. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL. DRAWING 300. E THE BUILDER IS RESPONSIBLE FOR VERTICAL AND HORIZONTAL ALIGNMENT OF CULVERT PIPE WITHIN THE RIGHT-OF-WAY.Sec 300.E * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" | |||
| INSULATION | 12/22/2025 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/15/2025 1:43:21 PM *** 12/15/25: Check at insulation. 1). Wires are not phased out in the main breaker panel. NEC 200.6(B) 2). Dryer exhaust needs to be sealed at all fitting joints and connections. FBCR M1601.4.1 3). Front entry door is missing Florida Product Approval sticker. (sticker on door does not include FPA number as required). FBC [A]107.4 12/11/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #2-Missing E-cals for inspection #3-Missing FL Approval for windows and doors Inspection not completed Inspector Notes from Inspection 2460 Missing engineering on truss T24 ( mark with green market ) | |||
| INSULATION | 12/19/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 12/19/25 1. Window in front left bedroom needs foam seal FBC 402.5.1.1 2. Chase above laundry needs to be fire foamed around perimiter as well as the hole where the dryer vent goes through FBCR 302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/15/2025 1:43:21 PM *** 12/15/25: Check at insulation. 1). Wires are not phased out in the main breaker panel. NEC 200.6(B) 2). Dryer exhaust needs to be sealed at all fitting joints and connections. FBCR M1601.4.1 3). Front entry door is missing Florida Product Approval sticker. (sticker on door does not include FPA number as required). FBC [A]107.4 12/11/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #2-Missing E-cals for inspection #3-Missing FL Approval for windows and doors Inspection not completed Inspector Notes from Inspection 2460 Missing engineering on truss T24 ( mark with green market ) | |||
| ALL ROUGH | 12/15/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/15/2025 1:43:21 PM *** 12/15/25: Check at insulation. 1). Wires are not phased out in the main breaker panel. NEC 200.6(B) 2). Dryer exhaust needs to be sealed at all fitting joints and connections. FBCR M1601.4.1 3). Front entry door is missing Florida Product Approval sticker. (sticker on door does not include FPA number as required). FBC [A]107.4 12/11/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #2-Missing E-cals for inspection #3-Missing FL Approval for windows and doors Inspection not completed Inspector Notes from Inspection 2460 Missing engineering on truss T24 ( mark with green market ) | |||
| LATH/BRICK/ WATER BARRIER | 12/12/2025 | APPROVED | MCONTRYMAN |
| ALL ROUGH | 12/11/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #2-Missing E-cals for inspection #3-Missing FL Approval for windows and doors Inspection not completed Inspector Notes from Inspection 2460 Missing engineering on truss T24 ( mark with green market ) | |||
| ELECTRIC-TUG | 12/10/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/08/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Missing engineering on truss T24 ( mark with green market ) | |||
| ROOF VALLEY & METAL | 12/05/2025 | APPROVED | JSTEWART |
| ROOF SHEATHING | 12/02/2025 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 12/02/2025 | APPROVED | CVANSTRAHLEN |
| TIE BEAM / LINTEL | 11/19/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| TIE BEAM / LINTEL | 11/17/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 11/17/2025 9:18:59 AM *** FBC 3302.2-NEEDS DUMPSTER ( please clean up trash and wasted ) PLease fix item before next inspection #1FBC [A]107.4- Replace window silt ( damage , crack , cut in half ) window silt need to be full side install ( window silt on left by front door | |||
| MONOLITHIC SLAB | 11/07/2025 | APPROVED | CVANSTRAHLEN |
| Note: 11/5/2025 - PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 11/05/2025 | CANCELLED BY APPLICANT | KSANDOE |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 11/04/2025 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/03/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2095 Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 10/30/2025 | APPROVED | JMUNSON |
| GRAVITY SEWER TEST | 10/28/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 10/28/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 10/09/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 11/04/2025 | 11/04/2025 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/04/2025 | 11/04/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/29/2025 | 10/30/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/21/2025 | 10/22/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/08/2025 | 10/09/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on the energy calcs and heatload need to be Daytona Beach | |||
| SWALE | COMPLETE | 03/28/2025 | 04/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/27/2025 | 03/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/27/2025 | 03/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/27/2025 | 03/31/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/27/2025 | 03/31/2025 |
| LOCATE | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/27/2025 | 03/31/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/13/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 03/13/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/13/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/13/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/13/2026 |
| SURCHARGE FS 533.721 | ¤11.52 | 09/25/2025 |
| SURCHARGE - FS 468.631 | ¤17.28 | 09/25/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/25/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/25/2025 |
| SW ENG PRE APRON | ¤30.00 | 09/25/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/25/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/25/2025 |
| SEWER INSPECTION | ¤25.00 | 09/25/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 09/25/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 09/25/2025 |
| SITE PLAN 30 | ¤30.00 | 09/25/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 09/25/2025 |
| IMPACT FEE FIRE | ¤434.51 | 09/25/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/25/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/25/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 09/25/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/25/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 09/25/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/25/2025 |
| CONNECTION FEES | ¤1,187.26 | 09/25/2025 |
| WATER- TURN ON | ¤25.00 | 09/25/2025 |
| ADJUSTMENT 10% | (¤127.96) | 09/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/25/2025 |
| INSPECTION - RESIDENTIAL | ¤973.50 | 09/25/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤276.12 | 09/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,748.40 |