I want to search for...

Permit #2025031224

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00280-0070
CONDITIONED SPACE: 1801 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2281 sqft
Block: 00280
Subdivision: -
Job Phone: 407-476-8195
Location Address: 16 WHITE OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/02/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LLC

Address

3670 MACGUIRE BOULEVARD

ORLANDO, FL 32803

Address

220

ORLANDO, FL 32803

Lot: 0070
Contracted Stated Job Value: ¤175,000.00
Job Description: single family residence
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/10/2026 FINAL APPROVED HCAMACHO
Note: 4/9/2026 - PREVIOUS INSPECTION NOTES 1. Missing house #. FBCR 319.1 ADDRESS POSTED – 4” 3/31/2026 - PREVIOUS INSPECTION NOTES Not ready, via phone.
BLD - BUILDING FINAL 04/09/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Missing house #. FBCR 319.1 ADDRESS POSTED – 4” 3/31/2026 - PREVIOUS INSPECTION NOTES Not ready, via phone.
BLD - BUILDING FINAL 03/31/2026 CANCELLED BY APPLICANT HCAMACHO
Note: Not ready, via phone.
ROW - FINAL APRON (AFTER POUR) 03/31/2026 APPROVED FSLADISH
Note: 3/31/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 03/31/2026 APPROVED FSLADISH
Note: 3/31/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 03/31/2026 FINAL APPROVED BHAINES
Note: Inspector Notes from Inspection 9035 No CC. No IRR
ROW FIELD SURVEY /GRADING CERTIFICATION 03/26/2026 CANCELLED BY INSPECTOR PFLANAGAN
Note: Letter from city on 3/25/26 this inspection is no longer being done.
U-CROSS CONNECTION 03/26/2026 APPROVED - AS NOTED BWRIGHT
Note: No CC. No IRR
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/25/2026 APPROVED FSLADISH
Note: 3/25/26 BASED ON THE ENGINEER SIGNED AND SEALED LDAGC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective today, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types.
ROW- PRE-APRON (PRE-POUR) 03/10/2026 APPROVED TPOLACEK
Note: 03-10-26 TPOLACEK*** FORM BOARDS AT END OF CULVERT PIPE SHOULD BE MOVED CLOSER TO PIPE. FORMS SHOULD BE BETWEEN 3" & 6" FROM END OF PIPE. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
ELECTRIC - EARLY POWER 02/27/2026 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2200 12/15/25 E-mailed FPL @ 12pm
GRAVITY SEWER TEST 02/12/2026 APPROVED MCONTRYMAN
SEWER TIE IN 02/12/2026 APPROVED MCONTRYMAN
PEP TANK INSTALLATION REQUEST 02/03/2026 APPROVED CBOWERMASTER
INSULATION 01/30/2026 APPROVED MKRASKI
ALL ROUGH 01/26/2026 APPROVED MKRASKI
ALL ROUGH 01/14/2026 Disapproved -FEE REQUIRED MKRASKI
Note: 1/14/26 1. Repair for missed straps not done per engineered letter 2. Both swinging exterior doors do not match product approval sheet 3. Seal slab at wall for elec. chase for island power FBC EC R402.4.1.1 4. Seal block at fridge water box FBCR P304.4 5. No 50 lbs of pressure on supply lines FBCR P2503.5 6. Bushing required where conduit goes into soffit for SER to protect it from damage NEC 300.16(B) 7. Master bathroom vent requires blocking around annular space FBCR P304.4 8. Missing vent to roof per plans at island (plans show loop vent to roof on S 2.0) 1/6/26 1. Remain items from tie down inspection still not repaired 2. Missed wet straps can not be more then 3 in a row at CMU to truss over SGD per feild repair note #4 3. Still need clairfcation on detail CD04 on S3.0 Letters are required and will need to be approved a full all rough inspection will be done once items from previous inspection have been completed and approved
ALL ROUGH 01/06/2026 Disapproved -FEE REQUIRED MKRASKI
Note: 1/6/26 1. Remain items from tie down inspection still not repaired 2. Missed wet straps can not be more then 3 in a row at CMU to truss over SGD per feild repair note #4 3. Still need clairfcation on detail CD04 on S3.0 Letters are required and will need to be approved a full all rough inspection will be done once items from previous inspection have been completed and approved
ROOF VALLEY & METAL 12/30/2025 APPROVED MKRASKI
ROOF VALLEY & METAL 12/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix item before next inspection synthetic Underlayment must be under dripedge 12/19/2025 - PREVIOUS INSPECTION NOTES 12/19/25 Previous note not rectified Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/26/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix tems before next inspection Number #6 and #7 front previous inspection 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 12/15/2025 - PREVIOUS INSPECTION NOTES 12/15/25 1. No truss engineering on site FBC 107.3.1 2. Clean job site 3. Multiple truss and gussett plates cut in garage exterior wall at raised heel a engineered repair letter is required 4. Raised heel truss's in garage not per detail 5. Multiple missed wet set straps need a engineered repair letter, plans show not more then 10 total and no more the 3 in a row 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 8. Truss T09 and T10 missing 2 wet set straps per detail "M" on roof framing detail Not ready for inspection a complete re-inspection will be required please have all repair letters approved by Building Dept and have repairs made before re-inspection
LATH/BRICK/ WATER BARRIER 12/26/2025 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 12/19/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 12/19/25 Previous note not rectified Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer
ROOF VALLEY & METAL 12/17/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer
WALL SHEATHING 12/15/2025 APPROVED - AS NOTED MKRASKI
Note: 12/15/25 1. Wall sheathing on right side of home (abover elec. meter) is not nailed off properly per plans 12/11/25 Not ready
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/15/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 12/15/25 1. No truss engineering on site FBC 107.3.1 2. Clean job site 3. Multiple truss and gussett plates cut in garage exterior wall at raised heel a engineered repair letter is required 4. Raised heel truss's in garage not per detail 5. Multiple missed wet set straps need a engineered repair letter, plans show not more then 10 total and no more the 3 in a row 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 8. Truss T09 and T10 missing 2 wet set straps per detail "M" on roof framing detail Not ready for inspection a complete re-inspection will be required please have all repair letters approved by Building Dept and have repairs made before re-inspection
ELECTRIC-TUG 12/15/2025 APPROVED - AS NOTED MKRASKI
Note: 12/15/25 E-mailed FPL @ 12pm
ELECTRIC-TUG 12/11/2025 Disapproved - NO FEE MKRASKI
Note: 1. Repair silt fence FBC 3307.1 2. Label breakers NEC 408.4 3. Surge is required in meter main NEC 230.67
WALL SHEATHING 12/11/2025 Disapproved - NO FEE MKRASKI
Note: Not ready
ROOF SHEATHING 12/11/2025 APPROVED MKRASKI
FORMBOARD SURVEY (OFFICE USE ONLY) 12/05/2025 APPROVED RRICKS
TIE BEAM / LINTEL 12/03/2025 APPROVED MKRASKI
MONOLITHIC SLAB 11/20/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/20/2025 10:55:52 AM *** 11/19/2025 - PREVIOUS INSPECTION NOTES 1. Entire slab must be a min of 4'' per notes on foundation page FBC R506.1 2. Back fill footings up to form boards (or add form boards) to match footing detail 3. Make sure all rebar has proper clearence from earth per (couple locations marked on print) FBC R404.1.3.3.7.4 4. Rebar in footing does not have proper coverage (plumbing lines form board steaks etc) FBCR 606.3.4 5. Repair silt fence to orginal condition through out build (extend to swale not through) FBC 3307.1 6. Remove porta jon from swale to allow water to flow freely FBC 3303.5 7. Address must be visible from road FBC 319.1
MONOLITHIC SLAB 11/19/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Entire slab must be a min of 4'' per notes on foundation page FBC R506.1 2. Back fill footings up to form boards (or add form boards) to match footing detail 3. Make sure all rebar has proper clearence from earth per (couple locations marked on print) FBC R404.1.3.3.7.4 4. Rebar in footing does not have proper coverage (plumbing lines form board steaks etc) FBCR 606.3.4 5. Repair silt fence to orginal condition through out build (extend to swale not through) FBC 3307.1 6. Remove porta jon from swale to allow water to flow freely FBC 3303.5 7. Address must be visible from road FBC 319.1
PLUMBING 1ST ROUGH UNDERGROUND 11/14/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 11/12/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 09/26/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 01/20/2026 01/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BADMIN INFORMATION 01/14/2026 01/14/2026
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PROD APP SHEET MISSING ADDRESS
BLD COMPLETE 01/14/2026 01/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/09/2026 01/12/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/17/2025 12/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 12/04/2025 12/05/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/04/2025 12/04/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 11/10/2025 11/12/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SWALE COMPLETE 03/28/2025 04/04/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 03/27/2025 04/01/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 03/27/2025 04/01/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/27/2025 03/27/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 03/27/2025 04/01/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/27/2025 03/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/27/2025 03/31/2025
LOCATE COMPLETE 03/27/2025 03/28/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 03/27/2025 03/31/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/27/2025 03/28/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/27/2025 03/27/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
REINSPECTION RESIDENTIAL ¤40.00 04/10/2026
CONNECTION FEES ¤1,187.26 09/02/2025
FC IMPACT FEE EMS ¤62.00 09/02/2025
IMPACT FEE FIRE ¤434.51 09/02/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/02/2025
FC IMPACT FEE LIBRARY ¤268.00 09/02/2025
IMPACT FEE PARKS ¤1,828.01 09/02/2025
IMPACT FEE SCHOOL ¤5,450.00 09/02/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 09/02/2025
WATER -IRRIGATION INSPECTION ¤25.00 09/02/2025
SURCHARGE FS 533.721 ¤10.85 09/02/2025
SURCHARGE - FS 468.631 ¤16.28 09/02/2025
SW ENG - FOUNDATION SURVEY ¤20.00 09/02/2025
SW ENG INSPECTION 80 ¤80.00 09/02/2025
SW ENG PRE APRON ¤30.00 09/02/2025
SW ENG - REVIEW 20 ¤20.00 09/02/2025
SW ENG RES REVIEW 200 ¤200.00 09/02/2025
SEWER CREDIT (¤1,143.00) 09/02/2025
SEWER INSPECTION ¤25.00 09/02/2025
SEWER CAPITAL FACILITY ¤6,120.52 09/02/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 09/02/2025
SITE PLAN 30 ¤30.00 09/02/2025
WATER- TURN ON ¤25.00 09/02/2025
ADJUSTMENT 10% (¤120.55) 09/02/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/02/2025
INSPECTION - RESIDENTIAL ¤915.75 09/02/2025
PLAN REVIEW - RESIDENTIAL ¤259.74 09/02/2025
Fees Total Due: ¤0.00 Total Paid: ¤22,572.01