I want to search for...
Permit #2025031224
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00280-0070 |
| CONDITIONED SPACE: 1801 sqft |
| GARAGE: 406 sqft |
| OPENED PORCH (WITH ROOF) : 58 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2281 sqft |
| Block: 00280 |
| Subdivision: - |
| Job Phone: 407-476-8195 |
| Location Address: 16 WHITE OAK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/02/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LLC |
|
Address 3670 MACGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address 220 ORLANDO, FL 32803 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤175,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/10/2026 | FINAL APPROVED | HCAMACHO |
| Note: 4/9/2026 - PREVIOUS INSPECTION NOTES 1. Missing house #. FBCR 319.1 ADDRESS POSTED – 4” 3/31/2026 - PREVIOUS INSPECTION NOTES Not ready, via phone. | |||
| BLD - BUILDING FINAL | 04/09/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Missing house #. FBCR 319.1 ADDRESS POSTED – 4” 3/31/2026 - PREVIOUS INSPECTION NOTES Not ready, via phone. | |||
| BLD - BUILDING FINAL | 03/31/2026 | CANCELLED BY APPLICANT | HCAMACHO |
| Note: Not ready, via phone. | |||
| ROW - FINAL APRON (AFTER POUR) | 03/31/2026 | APPROVED | FSLADISH |
| Note: 3/31/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 03/31/2026 | APPROVED | FSLADISH |
| Note: 3/31/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/31/2026 | FINAL APPROVED | BHAINES |
| Note: Inspector Notes from Inspection 9035 No CC. No IRR | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/26/2026 | CANCELLED BY INSPECTOR | PFLANAGAN |
| Note: Letter from city on 3/25/26 this inspection is no longer being done. | |||
| U-CROSS CONNECTION | 03/26/2026 | APPROVED - AS NOTED | BWRIGHT |
| Note: No CC. No IRR | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/25/2026 | APPROVED | FSLADISH |
| Note: 3/25/26 BASED ON THE ENGINEER SIGNED AND SEALED LDAGC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective today, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/10/2026 | APPROVED | TPOLACEK |
| Note: 03-10-26 TPOLACEK*** FORM BOARDS AT END OF CULVERT PIPE SHOULD BE MOVED CLOSER TO PIPE. FORMS SHOULD BE BETWEEN 3" & 6" FROM END OF PIPE. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" | |||
| ELECTRIC - EARLY POWER | 02/27/2026 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2200 12/15/25 E-mailed FPL @ 12pm | |||
| GRAVITY SEWER TEST | 02/12/2026 | APPROVED | MCONTRYMAN |
| SEWER TIE IN | 02/12/2026 | APPROVED | MCONTRYMAN |
| PEP TANK INSTALLATION REQUEST | 02/03/2026 | APPROVED | CBOWERMASTER |
| INSULATION | 01/30/2026 | APPROVED | MKRASKI |
| ALL ROUGH | 01/26/2026 | APPROVED | MKRASKI |
| ALL ROUGH | 01/14/2026 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1/14/26 1. Repair for missed straps not done per engineered letter 2. Both swinging exterior doors do not match product approval sheet 3. Seal slab at wall for elec. chase for island power FBC EC R402.4.1.1 4. Seal block at fridge water box FBCR P304.4 5. No 50 lbs of pressure on supply lines FBCR P2503.5 6. Bushing required where conduit goes into soffit for SER to protect it from damage NEC 300.16(B) 7. Master bathroom vent requires blocking around annular space FBCR P304.4 8. Missing vent to roof per plans at island (plans show loop vent to roof on S 2.0) 1/6/26 1. Remain items from tie down inspection still not repaired 2. Missed wet straps can not be more then 3 in a row at CMU to truss over SGD per feild repair note #4 3. Still need clairfcation on detail CD04 on S3.0 Letters are required and will need to be approved a full all rough inspection will be done once items from previous inspection have been completed and approved | |||
| ALL ROUGH | 01/06/2026 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1/6/26 1. Remain items from tie down inspection still not repaired 2. Missed wet straps can not be more then 3 in a row at CMU to truss over SGD per feild repair note #4 3. Still need clairfcation on detail CD04 on S3.0 Letters are required and will need to be approved a full all rough inspection will be done once items from previous inspection have been completed and approved | |||
| ROOF VALLEY & METAL | 12/30/2025 | APPROVED | MKRASKI |
| ROOF VALLEY & METAL | 12/26/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix item before next inspection synthetic Underlayment must be under dripedge 12/19/2025 - PREVIOUS INSPECTION NOTES 12/19/25 Previous note not rectified Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/26/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix tems before next inspection Number #6 and #7 front previous inspection 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 12/15/2025 - PREVIOUS INSPECTION NOTES 12/15/25 1. No truss engineering on site FBC 107.3.1 2. Clean job site 3. Multiple truss and gussett plates cut in garage exterior wall at raised heel a engineered repair letter is required 4. Raised heel truss's in garage not per detail 5. Multiple missed wet set straps need a engineered repair letter, plans show not more then 10 total and no more the 3 in a row 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 8. Truss T09 and T10 missing 2 wet set straps per detail "M" on roof framing detail Not ready for inspection a complete re-inspection will be required please have all repair letters approved by Building Dept and have repairs made before re-inspection | |||
| LATH/BRICK/ WATER BARRIER | 12/26/2025 | APPROVED | CVANSTRAHLEN |
| ROOF VALLEY & METAL | 12/19/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 12/19/25 Previous note not rectified Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer | |||
| ROOF VALLEY & METAL | 12/17/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/17/25 Underlayment must have 2 layers of synthetic over roof decking per approved roofing worksheet, Multiple locations at drip edge only have one layer | |||
| WALL SHEATHING | 12/15/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 12/15/25 1. Wall sheathing on right side of home (abover elec. meter) is not nailed off properly per plans 12/11/25 Not ready | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/15/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/15/25 1. No truss engineering on site FBC 107.3.1 2. Clean job site 3. Multiple truss and gussett plates cut in garage exterior wall at raised heel a engineered repair letter is required 4. Raised heel truss's in garage not per detail 5. Multiple missed wet set straps need a engineered repair letter, plans show not more then 10 total and no more the 3 in a row 6. No truss straping over SGD CMU 7. Plans show a detail CD04 on S.3 but no detail in plans 8. Truss T09 and T10 missing 2 wet set straps per detail "M" on roof framing detail Not ready for inspection a complete re-inspection will be required please have all repair letters approved by Building Dept and have repairs made before re-inspection | |||
| ELECTRIC-TUG | 12/15/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 12/15/25 E-mailed FPL @ 12pm | |||
| ELECTRIC-TUG | 12/11/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Repair silt fence FBC 3307.1 2. Label breakers NEC 408.4 3. Surge is required in meter main NEC 230.67 | |||
| WALL SHEATHING | 12/11/2025 | Disapproved - NO FEE | MKRASKI |
| Note: Not ready | |||
| ROOF SHEATHING | 12/11/2025 | APPROVED | MKRASKI |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 12/05/2025 | APPROVED | RRICKS |
| TIE BEAM / LINTEL | 12/03/2025 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 11/20/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/20/2025 10:55:52 AM *** 11/19/2025 - PREVIOUS INSPECTION NOTES 1. Entire slab must be a min of 4'' per notes on foundation page FBC R506.1 2. Back fill footings up to form boards (or add form boards) to match footing detail 3. Make sure all rebar has proper clearence from earth per (couple locations marked on print) FBC R404.1.3.3.7.4 4. Rebar in footing does not have proper coverage (plumbing lines form board steaks etc) FBCR 606.3.4 5. Repair silt fence to orginal condition through out build (extend to swale not through) FBC 3307.1 6. Remove porta jon from swale to allow water to flow freely FBC 3303.5 7. Address must be visible from road FBC 319.1 | |||
| MONOLITHIC SLAB | 11/19/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Entire slab must be a min of 4'' per notes on foundation page FBC R506.1 2. Back fill footings up to form boards (or add form boards) to match footing detail 3. Make sure all rebar has proper clearence from earth per (couple locations marked on print) FBC R404.1.3.3.7.4 4. Rebar in footing does not have proper coverage (plumbing lines form board steaks etc) FBCR 606.3.4 5. Repair silt fence to orginal condition through out build (extend to swale not through) FBC 3307.1 6. Remove porta jon from swale to allow water to flow freely FBC 3303.5 7. Address must be visible from road FBC 319.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/14/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/12/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 09/26/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/20/2026 | 01/20/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/14/2026 | 01/14/2026 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PROD APP SHEET MISSING ADDRESS | |||
| BLD | COMPLETE | 01/14/2026 | 01/20/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/09/2026 | 01/12/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/17/2025 | 12/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/04/2025 | 12/05/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/04/2025 | 12/04/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/10/2025 | 11/12/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/28/2025 | 04/04/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/27/2025 | 04/01/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/27/2025 | 03/31/2025 |
| LOCATE | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/27/2025 | 03/31/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/27/2025 | 03/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/27/2025 | 03/27/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2026 |
| CONNECTION FEES | ¤1,187.26 | 09/02/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 09/02/2025 |
| IMPACT FEE FIRE | ¤434.51 | 09/02/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/02/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/02/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 09/02/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/02/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 09/02/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/02/2025 |
| SURCHARGE FS 533.721 | ¤10.85 | 09/02/2025 |
| SURCHARGE - FS 468.631 | ¤16.28 | 09/02/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/02/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/02/2025 |
| SW ENG PRE APRON | ¤30.00 | 09/02/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/02/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/02/2025 |
| SEWER CREDIT | (¤1,143.00) | 09/02/2025 |
| SEWER INSPECTION | ¤25.00 | 09/02/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 09/02/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 09/02/2025 |
| SITE PLAN 30 | ¤30.00 | 09/02/2025 |
| WATER- TURN ON | ¤25.00 | 09/02/2025 |
| ADJUSTMENT 10% | (¤120.55) | 09/02/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/02/2025 |
| INSPECTION - RESIDENTIAL | ¤915.75 | 09/02/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤259.74 | 09/02/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,572.01 |