I want to search for...

Permit #2025031227

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01060-0150
CONDITIONED SPACE: 2622 sqft
GARAGE: 1084 sqft
OPENED PORCH (WITH ROOF) : 432 sqft
Total Square Footage: 4138 sqft
Block: 01060
Subdivision: -
Job Phone: 386-585-2654
Location Address: 55 LOUISIANA DR
Type: DU - DUPLEX
Issue Date: 04/14/2025
NOC: RECORDED
Applicant name: DESIDERIO CARLOS CARREIRO
Owner: TOP LUXURY HOMES LLC

Address

16 RIVERINA DR

PALM COAST, FL 32164

Lot: 0150
Contracted Stated Job Value: ¤400,000.00
Job Description: DUPLEX
Type: CN

Contractor

RED LINE CONSTRUCTION CO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
DESIDERIO CARLOS CARREIRO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/30/2026 FINAL APPROVED MCONTRYMAN
Note: 4/29/2026 - PREVIOUS INSPECTION NOTES 1. As part of unit Address please post A and B units. FBCR 319.1 Right unit......1. Seal the bottom of the liquid line wall chase. 2. Please seal around the dryer termination vent to wall. 3. Heat strip not marked for MOCP at AHU. FBCR M1303.1 4. Insulation cert needs posted near attic access. FBC EC R303.1.1.2 5. Garage door saftey devices need lowered to max 8" off floor. UL 325 Left Unit.....6. Dryer termination flapper is sealed closed by stucco (inoperable) FBC M1502.3 7. Insulation cert needs posted near attic access. FBC EC R303.1.1.2 8. Heat strip not marked for MOCP at AHU. FBCR M1303.1 9. Seal bottom of liquid line wall chase.
U -UTILITY RESIDENTIAL FINAL 04/30/2026 APPROVED TLOWE
BLD - BUILDING FINAL 04/29/2026 Disapproved - NO FEE JSTEWART
Note: 1. As part of unit Address please post A and B units. FBCR 319.1 Right unit......1. Seal the bottom of the liquid line wall chase. 2. Please seal around the dryer termination vent to wall. 3. Heat strip not marked for MOCP at AHU. FBCR M1303.1 4. Insulation cert needs posted near attic access. FBC EC R303.1.1.2 5. Garage door saftey devices need lowered to max 8" off floor. UL 325 Left Unit.....6. Dryer termination flapper is sealed closed by stucco (inoperable) FBC M1502.3 7. Insulation cert needs posted near attic access. FBC EC R303.1.1.2 8. Heat strip not marked for MOCP at AHU. FBCR M1303.1 9. Seal bottom of liquid line wall chase.
U-CROSS CONNECTION 04/29/2026 APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 04/29/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
FIREWALL FINAL 04/29/2026 APPROVED JSTEWART
ROW - FINAL INSPECTION 04/29/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/28/2026 APPROVED EMADISON
Note:
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/28/2026 APPROVED EMADISON
Note: ** Effective 03/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. ** PER P. BUCKLEY CHIEF BUILDING Inspector. ** SCHEDULE YOUR FINALS WHEN YOU ARE READY TO DO SO
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/16/2026 Disapproved - NO FEE PFLANAGAN
Note: Final Survey states that the water will impact the adjacent lot to the right of this lot please revise survey so no water will impact the adjacent lot. ----------------------------------------------------------- 3/25/26 Gabe and I went out and builder has put dirt on to adjacent lot behind this permited property. We spoke with the builder and homeowner about issue and contractor will be placing sod on all dirt on the adjacent lot. Also we are going to allow the hight point in the middle to be flat then drain to the right and left property drainage pattern. They also need to put a berm along the back so the water will not impact the adjacent lot behind this lot. Contact Gabe or Parren for any questions. ---------------------------------------------------------------------------------- 3/11/2026 - PREVIOUS INSPECTION NOTES ** 03/11/26 SURVEY SHOWS WATER DUMPING TO THE ADJACENT PROPERTY IN THE REAR 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16
ROW- PROJECT STATUS 03/25/2026 Status Check PFLANAGAN
Note: Gabe and I went out and builder has put dirt on to adjacent lot behind this permited property. We spoke with the builder and homeowner about issue and contractor will be placing sod on all dirt on the adjacent lot. Also we are going to allow the hight point in the middle to be flat then drain to the right and left property drainage pattern. They also need to put a berm along the back so the water will not impact the adjacent lot behind this lot. Contact Gabe or Parren for any questions.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/11/2026 Disapproved - NO FEE EMADISON
Note: ** 03/11/26 SURVEY SHOWS WATER DUMPING TO THE ADJACENT PROPERTY IN THE REAR 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16
ROW- PRE-APRON (PRE-POUR) 12/17/2025 APPROVED - AS NOTED TPOLACEK
Note: 12-17-25 TPOLACEK*** BOTH DRIVEWAYS ROADSIDE APRON FORM BOARDS MUST BE MOVED TO MATCH EXISTING EDGE OF ROAD AND BE AT LEAST 1" ABOVE THE EXISTING EDGE OF ROAD BUT NO MORE THAN 2". WHEN HOT PATCH IS COMPLETED ASPHALT MUST MATCH CONCRETE ELEVATION . APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ** 11/13/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY AND WATERWAYS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ____________________________________________________________________________________________________________________ 11/12/2025 - PREVIOUS INSPECTION NOTES STILL NEED TO INSTALL SILT FENCE OR USE OTHER BMP FOR STOPING SEDIMENT FROM GETTING INTO THE FRONT ROADSIDE SWALE. NEXT INSPECTION WILL BE FRIDAY 11/14/25 TO SEE IF CORRECTION MADE ------------------------------------------------------------------------------------------- 11/10/2025 - PREVIOUS INSPECTION NOTES 11-10-25 TPOLACEK*** BUILDER STILL NEEDS TO OPEN SWALE AND CLEAN OUT TEMPORARY PIPE AS WELL AS REPAIR ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE AS REQUIRED BY COPC. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/4/2025 - PREVIOUS INSPECTION NOTES 11-04-2025 TPOLACEK*** BUILDER MUST REMOVE PALLET AND STACK OF CONCRETE BAGS FROM ROW, OPEN SWALE TO ALLOW DRAINAGE TO FLOW, REESTABLISH TEMPORARY PIPE, REESTABLISH ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE IN FRONT. BUILDER HAS 5 DAYS TO COMPLY
GRAVITY SEWER TEST 12/10/2025 APPROVED JSTEWART
Note: 12/8/2025 - PREVIOUS INSPECTION NOTES No 5ft Head test. FBCP 312.6 Gravity sewer test.
ELECTRIC - EARLY POWER 12/08/2025 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email
ELECTRIC - EARLY POWER 12/08/2025 CANCELLED BY APPLICANT WEB
SEWER TIE IN 12/08/2025 APPROVED JSTEWART
GRAVITY SEWER TEST 12/08/2025 Disapproved - NO FEE JSTEWART
Note: No 5ft Head test. FBCP 312.6 Gravity sewer test.
ROW - DRAINAGE 11/14/2025 APPROVED - AS NOTED EMADISON
Note: ** 11/13/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY AND WATERWAYS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ____________________________________________________________________________________________________________________ 11/12/2025 - PREVIOUS INSPECTION NOTES STILL NEED TO INSTALL SILT FENCE OR USE OTHER BMP FOR STOPING SEDIMENT FROM GETTING INTO THE FRONT ROADSIDE SWALE. NEXT INSPECTION WILL BE FRIDAY 11/14/25 TO SEE IF CORRECTION MADE ------------------------------------------------------------------------------------------- 11/10/2025 - PREVIOUS INSPECTION NOTES 11-10-25 TPOLACEK*** BUILDER STILL NEEDS TO OPEN SWALE AND CLEAN OUT TEMPORARY PIPE AS WELL AS REPAIR ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE AS REQUIRED BY COPC. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/4/2025 - PREVIOUS INSPECTION NOTES 11-04-2025 TPOLACEK*** BUILDER MUST REMOVE PALLET AND STACK OF CONCRETE BAGS FROM ROW, OPEN SWALE TO ALLOW DRAINAGE TO FLOW, REESTABLISH TEMPORARY PIPE, REESTABLISH ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE IN FRONT. BUILDER HAS 5 DAYS TO COMPLY
PEP TANK INSTALLATION REQUEST 11/13/2025 APPROVED CBOWERMASTER
ROW - DRAINAGE 11/12/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO INSTALL SILT FENCE OR USE OTHER BMP FOR STOPING SEDIMENT FROM GETTING INTO THE FRONT ROADSIDE SWALE. NEXT INSPECTION WILL BE FRIDAY 11/14/25 TO SEE IF CORRECTION MADE ------------------------------------------------------------------------------------------- 11/10/2025 - PREVIOUS INSPECTION NOTES 11-10-25 TPOLACEK*** BUILDER STILL NEEDS TO OPEN SWALE AND CLEAN OUT TEMPORARY PIPE AS WELL AS REPAIR ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE AS REQUIRED BY COPC. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/4/2025 - PREVIOUS INSPECTION NOTES 11-04-2025 TPOLACEK*** BUILDER MUST REMOVE PALLET AND STACK OF CONCRETE BAGS FROM ROW, OPEN SWALE TO ALLOW DRAINAGE TO FLOW, REESTABLISH TEMPORARY PIPE, REESTABLISH ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE IN FRONT. BUILDER HAS 5 DAYS TO COMPLY
ROW - DRAINAGE 11/10/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 11-10-25 TPOLACEK*** BUILDER STILL NEEDS TO OPEN SWALE AND CLEAN OUT TEMPORARY PIPE AS WELL AS REPAIR ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE AS REQUIRED BY COPC. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/4/2025 - PREVIOUS INSPECTION NOTES 11-04-2025 TPOLACEK*** BUILDER MUST REMOVE PALLET AND STACK OF CONCRETE BAGS FROM ROW, OPEN SWALE TO ALLOW DRAINAGE TO FLOW, REESTABLISH TEMPORARY PIPE, REESTABLISH ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE IN FRONT. BUILDER HAS 5 DAYS TO COMPLY
ROW - DRAINAGE 11/04/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 11-04-2025 TPOLACEK*** BUILDER MUST REMOVE PALLET AND STACK OF CONCRETE BAGS FROM ROW, OPEN SWALE TO ALLOW DRAINAGE TO FLOW, REESTABLISH TEMPORARY PIPE, REESTABLISH ALL SILT FENCE AND INSTALL CONSTRUCTION ENTRANCE IN FRONT. BUILDER HAS 5 DAYS TO COMPLY
LATH/BRICK/ WATER BARRIER 09/30/2025 APPROVED JSTEWART
INSULATION 09/18/2025 APPROVED FWILLIS
Note: 9/11/2025 - PREVIOUS INSPECTION NOTES Previous notes not rectified..... 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet Inspection.....1. Garage walls TP Penetrations require firestop. FBC R302.11(1.2) 2. Steel sleeve at Firewall requires fire putty at each end to seal passage. 3. Locations of walls that stud penetration exceed 10' require firestop (Romex penetration). FBC R302.11(1.2) Inspector Notes from Inspection 2443 Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/26/2025 11:37:30 AM *** NOTE: Please call in Firewall inspections prior to Insulation. 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet 3. Please seal concrete floor at tubs. 4. Change bonding wire at service connect to #4 conductor. per plan. Will check at Insulation.
INSULATION 09/11/2025 Disapproved -FEE REQUIRED JSTEWART
Note: Previous notes not rectified..... 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet Inspection.....1. Garage walls TP Penetrations require firestop. FBC R302.11(1.2) 2. Steel sleeve at Firewall requires fire putty at each end to seal passage. 3. Locations of walls that stud penetration exceed 10' require firestop (Romex penetration). FBC R302.11(1.2) Inspector Notes from Inspection 2443 Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/26/2025 11:37:30 AM *** NOTE: Please call in Firewall inspections prior to Insulation. 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet 3. Please seal concrete floor at tubs. 4. Change bonding wire at service connect to #4 conductor. per plan. Will check at Insulation.
FIREWALL DRYWALL NAILING 08/29/2025 APPROVED - AS NOTED JSTEWART
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/26/2025 11:37:30 AM *** NOTE: Please call in Firewall inspections prior to Insulation. 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet 3. Please seal concrete floor at tubs. 4. Change bonding wire at service connect to #4 conductor. per plan. Will check at Insulation.
FIREWALL FRAMING 08/29/2025 APPROVED - AS NOTED JSTEWART
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/26/2025 11:37:30 AM *** NOTE: Please call in Firewall inspections prior to Insulation. 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet 3. Please seal concrete floor at tubs. 4. Change bonding wire at service connect to #4 conductor. per plan. Will check at Insulation.
ALL ROUGH 08/26/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/26/2025 11:37:30 AM *** NOTE: Please call in Firewall inspections prior to Insulation. 1. Please submitt a revision of windows/doors installed (product approval). FBC [A]107.4 2. Please all apropriate Trusses cleaned from dirt from improper storage (ground contact) BCSI Truss summary sheet 3. Please seal concrete floor at tubs. 4. Change bonding wire at service connect to #4 conductor. per plan. Will check at Insulation.
ROOF VALLEY & METAL 08/07/2025 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2460 Right side unit, Please clean trusses, King hip, hip jacks from debri. Will check at all rough.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/05/2025 APPROVED - AS NOTED JSTEWART
Note: Right side unit, Please clean trusses, King hip, hip jacks from debri. Will check at all rough.
WALL SHEATHING 08/05/2025 APPROVED JSTEWART
TIE BEAM / LINTEL 06/30/2025 APPROVED FWILLIS
MONOLITHIC SLAB 06/11/2025 APPROVED JSTEWART
FORMBOARD SURVEY (OFFICE USE ONLY) 06/10/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 05/30/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/29/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/09/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BADMIN INFORMATION 03/09/2026 03/09/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM NOC of file is expired. No inspections can be scheduled until new NOC is submitted.
BLD COMPLETE 09/11/2025 09/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 08/18/2025 08/18/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 06/09/2025 06/09/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 05/29/2025 05/29/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 05/23/2025 05/27/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Density test needs to be accompanied with a certification from the engineer. Also, it needs to be digitally signed, sealed, and verifiable.
MECH COMPLETE 04/03/2025 04/08/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 04/03/2025 04/03/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 03/28/2025 04/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 03/28/2025 03/28/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan: all plans must match drive way dimensions dont match site plan
SW1 COMPLETE 03/27/2025 04/01/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
MECH HOLD 03/27/2025 03/31/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Provide Duct layout signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
LOCATE COMPLETE 03/27/2025 03/28/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
GAS CANCEL 03/27/2025 03/31/2025
ENGIN1 COMPLETE 03/27/2025 03/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ELEC COMPLETE 03/27/2025 04/01/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 03/27/2025 03/28/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
BLD COMPLETE 03/27/2025 04/02/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BADMIN COMPLETE 03/27/2025 04/02/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI GENERAL INSPECTION 32.50 ¤32.50 05/01/2026
RSI REINSPECTION 1 ¤35.00 05/01/2026
RSI REINSPECTION 1 ¤35.00 05/01/2026
RSI REINSPECTION 1 ¤35.00 05/01/2026
RSI REINSPECTION 1 ¤35.00 05/01/2026
PLAN REVIEW - REVISION ¤32.50 05/01/2026
REINSPECTION RESIDENTIAL ¤40.00 05/01/2026
CONTRACTOR CHANGE ¤20.00 08/18/2025
FC IMPACT FEE EMS ¤124.00 04/14/2025
IMPACT FEE FIRE ¤434.51 04/14/2025
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 04/14/2025
FC IMPACT FEE LIBRARY ¤536.00 04/14/2025
IMPACT FEE PARKS ¤1,828.01 04/14/2025
IMPACT FEE SCHOOL ¤5,450.00 04/14/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 04/14/2025
WATER -IRRIGATION INSPECTION ¤50.00 04/14/2025
CONNECTION FEES ¤2,374.52 04/14/2025
WATER- TURN ON ¤50.00 04/14/2025
ADJUSTMENT 10% (¤192.91) 04/14/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/14/2025
INSPECTION - RESIDENTIAL ¤1,479.50 04/14/2025
PLAN REVIEW - RESIDENTIAL ¤419.64 04/14/2025
SURCHARGE FS 533.721 ¤17.36 04/14/2025
SURCHARGE - FS 468.631 ¤26.04 04/14/2025
SW ENG - FOUNDATION SURVEY ¤20.00 04/14/2025
SW ENG INSPECTION 80 ¤80.00 04/14/2025
SW ENG PRE APRON ¤30.00 04/14/2025
SW ENG - REVIEW 20 ¤20.00 04/14/2025
SW ENG RES REVIEW 200 ¤200.00 04/14/2025
SEWER CREDIT (¤1,420.00) 04/14/2025
SEWER INSPECTION ¤25.00 04/14/2025
SEWER CAPITAL FACILITY ¤12,241.04 04/14/2025
WATER CAPITAL FACILITY FEE ¤8,702.28 04/14/2025
SITE PLAN 30 ¤30.00 04/14/2025
Fees Total Due: ¤0.00 Total Paid: ¤35,171.99