I want to search for...

Permit #2025031266

Permit Details

Status: FINAL

Parcel Id: 07-11-31-1040-00000-0570
Block: 00000
Subdivision: 1040 - BON TERRA ESTATES
Job Phone: 786-512-4421
Location Address: 7 LEWISDALE LN
Type: DR - DRIVEWAY
Issue Date: 04/09/2025
NOC: RECORDED
Applicant name: ABEL MENENDEZ
Owner: GROBDRUCK JEFFREY S & GLORIA A GROBDRUCK H&W

Address

7 LEWISDALE LN

PALM COAST, FL 32137

Lot: 0570
Contracted Stated Job Value: ¤22,000.00
Job Description: Replace existing concrete drive way & Walk way with pavers New drive way size 36
Type: CN

Contractor

ROYAL TILE & PAVERS INC
Status Location Address Phone
ACTIVE

69 FLEETWOOD DR

PALM COAST, FL 32137

786-512-4421

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/23/2025 FINAL APPROVED DHANEY
ROW - FINAL APRON (AFTER POUR) 06/17/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - FINAL INSPECTION 06/17/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- PRE-APRON (PRE-POUR) 04/25/2025 APPROVED FSLADISH
Note: 4/25/25 YOU ARE APPROVED TO LAY PAVERS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION _______________________________________________________________________________________________________________________ 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 4/16/2025 - PREVIOUS INSPECTION NOTES 4/16/25 You are required to have a 5 ft wide sidewalk poured concrete minimum 6" deep between the driveway apron and meeting the front of the right of way. You are not allowed to have a full paver driveway in areas where a sidewalk is present. Sidewalks constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk shall be a minimum of 4" thick concrete. Sidewalks at driveway/turnout crossings shall be a minimum of 6" thick concrete. Section 400.02 reference.
ROW- PAVER RESTRAINTS 04/22/2025 APPROVED FSLADISH
Note: 4/22/25 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 04/22/2025 PARTIALLY APPROVED FSLADISH
Note: 4/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 4/16/2025 - PREVIOUS INSPECTION NOTES 4/16/25 You are required to have a 5 ft wide sidewalk poured concrete minimum 6" deep between the driveway apron and meeting the front of the right of way. You are not allowed to have a full paver driveway in areas where a sidewalk is present. Sidewalks constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk shall be a minimum of 4" thick concrete. Sidewalks at driveway/turnout crossings shall be a minimum of 6" thick concrete. Section 400.02 reference.
ROW- PRE-APRON (PRE-POUR) 04/16/2025 Disapproved - NO FEE FSLADISH
Note: 4/16/25 You are required to have a 5 ft wide sidewalk poured concrete minimum 6" deep between the driveway apron and meeting the front of the right of way. You are not allowed to have a full paver driveway in areas where a sidewalk is present. Sidewalks constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk shall be a minimum of 4" thick concrete. Sidewalks at driveway/turnout crossings shall be a minimum of 6" thick concrete. Section 400.02 reference.

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 03/31/2025 03/31/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
UTL COMPLETE 03/28/2025 04/03/2025
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2025 03/28/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 04/09/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/09/2025
RECORDING FEE REIMBURSE DOC ¤44.00 04/09/2025
SW ENG INSPECTION 40 ¤40.00 04/09/2025
SW ENG PRE APRON ¤30.00 04/09/2025
SW ENG RES REVIEW 200 ¤200.00 04/09/2025
SITE PLAN 15 ¤15.00 04/09/2025
Fees Total Due: ¤0.00 Total Paid: ¤356.00