I want to search for...
Permit #2025031274
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7025-00210-0110 |
| CONDITIONED SPACE: 1247 sqft |
| GARAGE: 473 sqft |
| OPENED PORCH (WITH ROOF) : 152 sqft |
| Total Square Footage: 1872 sqft |
| Block: 00210 |
| Subdivision: - |
| Job Phone: 844-885-8913 |
| Location Address: 153 PARKVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/08/2025 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES-FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE THE WOODLANDS, TX 77380 |
|
Address STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
CHRISTOPHER DENNIS O'CONNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 N LAKE CUNNINGHAM AVE JACKSONVILLE, FL 32257 |
ER13015361 (Exp: 08/31/2026) | 904-540-0858 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
Inspection History
| Type | Request Date | Result | Inspector |
| SEWER TIE IN | 06/04/2026 | APPROVED | JSTEWART |
| Note: Live virtual inspection. 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: City needs to correct pitch on lateral sewer as it currently has fall back to the house. | |||
| INSULATION | 05/27/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 5/26/26: NOT READY! Firestop/fireblocking not completed as of today's inspection. Builder to check all cardboard baffles for 1" minimum clearance. FBC-R806.3 (many do not meet requirements). New inspection due to canceled inspection Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| LATH/BRICK/ WATER BARRIER | 05/26/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/26/2026 9:37:03 AM *** Approved 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: 1). Front door has over the 1/4" maximum shim spacing along the top jamb and will require solid blocking along the entire jamb. (please remove shims and replace with solid blocking before installing new shims). FBCR 609.1 2). T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection. **** NOT REPAIRED AS REQUIRED. * SEE HIGHLIGHTED DETAIL IN MiTek PACKET. FBC- R302.4 Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| INSULATION | 05/26/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/26/2026 9:40:56 AM *** 5/26/26: NOT READY! Firestop/fireblocking not completed as of today's inspection. Builder to check all cardboard baffles for 1" minimum clearance. FBC-R806.3 (many do not meet requirements). New inspection due to canceled inspection Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| INSULATION | 05/22/2026 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| LATH/BRICK/ WATER BARRIER | 05/21/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/21/2026 3:09:24 PM *** 5/21/26: 1). Front door has over the 1/4" maximum shim spacing along the top jamb and will require solid blocking along the entire jamb. (please remove shims and replace with solid blocking before installing new shims). FBCR 609.1 2). T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection. **** NOT REPAIRED AS REQUIRED. * SEE HIGHLIGHTED DETAIL IN MiTek PACKET. FBC- R302.4 Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| GRAVITY SEWER TEST | 05/21/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/21/2026 12:13:55 PM *** 5/21/26: Virtually approved via FaceTime video/audio phone app at @ 1204. | |||
| SEWER TIE IN | 05/21/2026 | Disapproved - NO FEE | RSIMS |
| Note: 5/21/26: City needs to correct pitch on lateral sewer as it currently has fall back to the house. | |||
| ALL ROUGH | 05/19/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| ELECTRIC-TUG | 05/18/2026 | APPROVED | HCAMACHO |
| WALL SHEATHING | 05/04/2026 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/04/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection. | |||
| ROOF VALLEY & METAL | 05/04/2026 | APPROVED | HCAMACHO |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 05/01/2026 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 04/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/20/2026 8:59:25 AM *** Approved | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/17/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/17/2026 9:49:16 AM *** Approved | |||
| ROW - DRAINAGE | 08/15/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/8/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTCHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf | |||
| ROW - DRAINAGE | 08/08/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTCHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf | |||
| WATER METER INSTALLATION REQUEST | 05/22/2025 | APPROVED | CBOWERMASTER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 05/21/2025 | APPROVED | JMUNSON |
| ELECTRIC - EARLY POWER | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/18/2026 | 05/18/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/30/2026 | 04/30/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Benchmark does not match approved grading plan, benchmark shall be maintained throughout construction cycle. | |||
| ZON | COMPLETE | 04/30/2026 | 04/30/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/30/2026 | 05/01/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/30/2026 | 04/30/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/30/2025 | 09/30/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/29/2025 | 09/29/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/30/2025 | 06/02/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/21/2025 | 05/21/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/19/2025 | 05/19/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not schedule Geo Tech inspection due to NOC | |||
| BADMIN | INFORMATION | 05/16/2025 | 05/16/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC needs to be recorded at Flagler Clerk of Courts. | |||
| ZON | COMPLETE | 04/03/2025 | 04/03/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/03/2025 | 04/03/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/03/2025 | 04/09/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/03/2025 | 04/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/28/2025 | 04/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/28/2025 | 04/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/28/2025 | 03/28/2025 |
| Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/28/2025 | 04/02/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/28/2025 | 03/28/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/28/2025 | 04/01/2025 |
| LOCATE | COMPLETE | 03/28/2025 | 04/01/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/28/2025 | 04/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/28/2025 | 04/01/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/28/2025 | 03/28/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan: 1.Map panel number incorrect should be 0137E |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | 05/08/2025 |
| ADJUSTMENT 10% | (¤108.90) | 05/08/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/08/2025 |
| INSPECTION - RESIDENTIAL | ¤825.00 | 05/08/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤234.00 | 05/08/2025 |
| CONNECTION FEES | ¤1,187.26 | 05/08/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 05/08/2025 |
| IMPACT FEE FIRE | ¤434.51 | 05/08/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/08/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/08/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 05/08/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/08/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 05/08/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/08/2025 |
| SURCHARGE FS 533.721 | ¤9.80 | 05/08/2025 |
| SURCHARGE - FS 468.631 | ¤14.70 | 05/08/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/08/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/08/2025 |
| SW ENG PRE APRON | ¤30.00 | 05/08/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/08/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/08/2025 |
| SEWER CREDIT | (¤850.00) | 05/08/2025 |
| SEWER INSPECTION | ¤25.00 | 05/08/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 05/08/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 05/08/2025 |
| SITE PLAN 30 | ¤30.00 | 05/08/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | |
| SW ENG - INSPECTION 20 | ¤20.00 | |
| PLAN REVIEW - REVISION | ¤32.50 | |
| PLAN REVIEW - REVISION | ¤32.50 | |
| EXTENSION | ¤40.00 | |