I want to search for...

Permit #2025031274

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7025-00210-0110
CONDITIONED SPACE: 1247 sqft
GARAGE: 473 sqft
OPENED PORCH (WITH ROOF) : 152 sqft
Total Square Footage: 1872 sqft
Block: 00210
Subdivision: -
Job Phone: 844-885-8913
Location Address: 153 PARKVIEW DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/08/2025
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0110
Contracted Stated Job Value: ¤300,000.00
Job Description: Single Family Residence
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131

Inspection History

Type Request Date Result Inspector
SEWER TIE IN 06/04/2026 APPROVED JSTEWART
Note: Live virtual inspection. 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: City needs to correct pitch on lateral sewer as it currently has fall back to the house.
INSULATION 05/27/2026 APPROVED CVANSTRAHLEN
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 5/26/26: NOT READY! Firestop/fireblocking not completed as of today's inspection. Builder to check all cardboard baffles for 1" minimum clearance. FBC-R806.3 (many do not meet requirements). New inspection due to canceled inspection Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
LATH/BRICK/ WATER BARRIER 05/26/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/26/2026 9:37:03 AM *** Approved 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: 1). Front door has over the 1/4" maximum shim spacing along the top jamb and will require solid blocking along the entire jamb. (please remove shims and replace with solid blocking before installing new shims). FBCR 609.1 2). T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection. **** NOT REPAIRED AS REQUIRED. * SEE HIGHLIGHTED DETAIL IN MiTek PACKET. FBC- R302.4 Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
INSULATION 05/26/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/26/2026 9:40:56 AM *** 5/26/26: NOT READY! Firestop/fireblocking not completed as of today's inspection. Builder to check all cardboard baffles for 1" minimum clearance. FBC-R806.3 (many do not meet requirements). New inspection due to canceled inspection Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
INSULATION 05/22/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
LATH/BRICK/ WATER BARRIER 05/21/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 3:09:24 PM *** 5/21/26: 1). Front door has over the 1/4" maximum shim spacing along the top jamb and will require solid blocking along the entire jamb. (please remove shims and replace with solid blocking before installing new shims). FBCR 609.1 2). T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection. **** NOT REPAIRED AS REQUIRED. * SEE HIGHLIGHTED DETAIL IN MiTek PACKET. FBC- R302.4 Inspector Notes from Inspection 2420 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
GRAVITY SEWER TEST 05/21/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 12:13:55 PM *** 5/21/26: Virtually approved via FaceTime video/audio phone app at @ 1204.
SEWER TIE IN 05/21/2026 Disapproved - NO FEE RSIMS
Note: 5/21/26: City needs to correct pitch on lateral sewer as it currently has fall back to the house.
ALL ROUGH 05/19/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Missing Front Door 2. T13 in the garage has broken web Need repair according to MYtek. Scab needs to be full length of web.*This is from previous inspection.* 3. Crushed duct in the kitchen. FBC M1301.3 Inspector Notes from Inspection 2460 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
ELECTRIC-TUG 05/18/2026 APPROVED HCAMACHO
WALL SHEATHING 05/04/2026 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/04/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. T13 in the garage has broken web, marked on plan. Need repair. Will check at Rough inspection.
ROOF VALLEY & METAL 05/04/2026 APPROVED HCAMACHO
FORMBOARD SURVEY (OFFICE USE ONLY) 05/01/2026 APPROVED RRICKS
MONOLITHIC SLAB 04/20/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/20/2026 8:59:25 AM *** Approved
PLUMBING 1ST ROUGH UNDERGROUND 04/17/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/17/2026 9:49:16 AM *** Approved
ROW - DRAINAGE 08/15/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/8/2025 - PREVIOUS INSPECTION NOTES TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTCHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf
ROW - DRAINAGE 08/08/2025 Disapproved - NO FEE TPOLACEK
Note: TPOLACEK*** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTCHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf
WATER METER INSTALLATION REQUEST 05/22/2025 APPROVED CBOWERMASTER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/21/2025 APPROVED JMUNSON
ELECTRIC - EARLY POWER
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - STORMWATER FINAL
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 05/18/2026 05/18/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/30/2026 04/30/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Benchmark does not match approved grading plan, benchmark shall be maintained throughout construction cycle.
ZON COMPLETE 04/30/2026 04/30/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SW1 COMPLETE 04/30/2026 05/01/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/30/2026 04/30/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
MECH COMPLETE 09/30/2025 09/30/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/29/2025 09/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 05/30/2025 06/02/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/21/2025 05/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 05/19/2025 05/19/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not schedule Geo Tech inspection due to NOC
BADMIN INFORMATION 05/16/2025 05/16/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC needs to be recorded at Flagler Clerk of Courts.
ZON COMPLETE 04/03/2025 04/03/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/03/2025 04/03/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 04/03/2025 04/09/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
SWALE COMPLETE 04/03/2025 04/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 03/28/2025 04/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 03/28/2025 04/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/28/2025 03/28/2025
Note: Released By: REBECCA SANDERS - - RSANDERS@PALMCOASTGOV.COM
ELEC COMPLETE 03/28/2025 04/02/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/28/2025 03/28/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/28/2025 04/01/2025
LOCATE COMPLETE 03/28/2025 04/01/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 03/28/2025 04/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/28/2025 04/01/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON HOLD 03/28/2025 03/28/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan: 1.Map panel number incorrect should be 0137E

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER- TURN ON ¤25.00 05/08/2025
ADJUSTMENT 10% (¤108.90) 05/08/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/08/2025
INSPECTION - RESIDENTIAL ¤825.00 05/08/2025
PLAN REVIEW - RESIDENTIAL ¤234.00 05/08/2025
CONNECTION FEES ¤1,187.26 05/08/2025
FC IMPACT FEE EMS ¤62.00 05/08/2025
IMPACT FEE FIRE ¤434.51 05/08/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/08/2025
FC IMPACT FEE LIBRARY ¤268.00 05/08/2025
IMPACT FEE PARKS ¤1,828.01 05/08/2025
IMPACT FEE SCHOOL ¤5,450.00 05/08/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 05/08/2025
WATER -IRRIGATION INSPECTION ¤25.00 05/08/2025
SURCHARGE FS 533.721 ¤9.80 05/08/2025
SURCHARGE - FS 468.631 ¤14.70 05/08/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/08/2025
SW ENG INSPECTION 80 ¤80.00 05/08/2025
SW ENG PRE APRON ¤30.00 05/08/2025
SW ENG - REVIEW 20 ¤20.00 05/08/2025
SW ENG RES REVIEW 200 ¤200.00 05/08/2025
SEWER CREDIT (¤850.00) 05/08/2025
SEWER INSPECTION ¤25.00 05/08/2025
SEWER CAPITAL FACILITY ¤6,120.52 05/08/2025
WATER CAPITAL FACILITY FEE ¤4,351.14 05/08/2025
SITE PLAN 30 ¤30.00 05/08/2025
SW ENG - INSPECTION 20 ¤20.00
SW ENG - INSPECTION 20 ¤20.00
PLAN REVIEW - REVISION ¤32.50
PLAN REVIEW - REVISION ¤32.50
EXTENSION ¤40.00
Fees Total Due: ¤145.00 Total Paid: ¤22,445.04