I want to search for...

Permit #2025031297

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7027-00460-0330
Block: 00460
Subdivision: -
Job Phone: 386-236-9610
Location Address: 16 WOOD CLIFT LN
Type: PO - POOL
Issue Date: 05/02/2025
NOC: RECORDED
Applicant name: SAMANTHA JESSICA ALEXANDER
Owner: BRITO ANTHONY MARQUES & CHRISTINE MARIE H&W LIFE E

Address

16 WOOD CLIFT LANE

PALM COAST, FL 32164

Lot: 0330
Contracted Stated Job Value: ¤65,000.00
Job Description: swimming pool w/ screen enclosure
Type: CN

Contractor

AGUA POOLS AND SPA INC
Status Location Address State License Number Phone
ACTIVE

3438 LONGLEAF ROAD

,

CPC1459907 (Exp: 08/31/2026) 386-492-6910

Sub Contractors

CHRISTOPHER I HALL
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 2413

Bunnell, FL 32110

EC13002161 (Exp: 08/31/2028) (386) 437-2966 386-437-5042
RAYMOND BRUCE KIMBALL JR
Status Location Address State License Number Phone
ACTIVE

150 HILDEN ROAD #312

PONTE VEDRA, FL 32081

CRC1334200 (Exp: 08/31/2026) 904-962-3032

Inspection History

Type Request Date Result Inspector
POOL FINAL 03/10/2026 FINAL APPROVED HCAMACHO
U -UTILITY RESIDENTIAL FINAL 03/09/2026 FINAL APPROVED BWRIGHT
ROW - FINAL INSPECTION 03/06/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PROJECT STATUS 03/04/2026 Status Check PFLANAGAN
Note: POOL BUILDER CREATED A SWALE ALONG BACK FENCE AND POND SO WATER WILL IMPACT THE ADJACENT LOTS SURROUND THIS PROJECT. PASSING AS NOTED THAT FIXES WAS MADE AND NOT REQUIRING FINAL SURVEY FOR THE CHANGES. ------------------------------------------------------------------------------ Looking at fixed grade from pool builder
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/04/2026 APPROVED - AS NOTED PFLANAGAN
Note: POOL BUILDER CREATED A SWALE ALONG BACK FENCE AND POND SO WATER WILL IMPACT THE ADJACENT LOTS SURROUND THIS PROJECT. PASSING AS NOTED THAT FIXES WAS MADE AND NOT REQUIRING FINAL SURVEY FOR THE CHANGES. -------------------------------------------------------------------------------- 12/2/2025 - PREVIOUS INSPECTION NOTES 12-2-25 TPOLACEK** PLEASE SEE ATTACHED PHOTO, REAR YARD MUST DRAIN TO THE FRONT SWALE AS APPROVED SITE PLAN INDICATED. DRAINAGE MUST NOT NEGATIVELY IMPACT ADJOINING LOTS. THERE MUST BE A MINIMUM OF A .30 DEEP SWALE AND .10 FALL EVERY 20' 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Technical Manual, Section 300.01 (D)(6) (V-!7) The top of the slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)Technical Manual, Section 300.01 (D)(6) (V-!7) Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17
ROW FIELD SURVEY /GRADING CERTIFICATION 03/04/2026 APPROVED PFLANAGAN
Note: PLEASE SEE NOTES ON FINAL SURVEY INSPECTION
ROW- PROJECT STATUS 02/20/2026 Status Check PFLANAGAN
Note: GABE AND I WENT OUT TO LOOK AT REPAIR AND THEY WILL NEED TO HAVE THE DRAINAGE PATTERN EXTENDED SO WATER WILL FLOW TO FRONT SWALE
ROW- PROJECT STATUS 02/06/2026 Status Check PFLANAGAN
Note: MET WITH POOL BUILDER AND RESIDENT AND DISCUSSED WHAT NEEDED TO BE COMPLETED TO MEET CITY STANDRADS FOR LOTS DRAINAGE. ITS THE BUILDER AND THE RESIDENT TO MAKE THE WATER FLOW CORRECTLY TO THE FONT ROADSIDE SWALE AND NOT IMPACT ADJACENT LOTS. ---------------------------------------------------------------------------------------- MEETING POOL BUILDER FOR FINAL SURVEY AND GRADING
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/02/2025 Disapproved - NO FEE TPOLACEK
Note: 12-2-25 TPOLACEK** PLEASE SEE ATTACHED PHOTO, REAR YARD MUST DRAIN TO THE FRONT SWALE AS APPROVED SITE PLAN INDICATED. DRAINAGE MUST NOT NEGATIVELY IMPACT ADJOINING LOTS. THERE MUST BE A MINIMUM OF A .30 DEEP SWALE AND .10 FALL EVERY 20' 15 Negatively impact Sec 300.01 (A)(1)(C)(6) Sec 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) Technical Manual, Section 300.01 (D)(6) (V-!7) The top of the slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)Technical Manual, Section 300.01 (D)(6) (V-!7) Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17
ELECTRIC AND ALARM 06/26/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/26/2025 2:35:35 PM ***
ELECTRIC AND ALARM 06/13/2025 CANCELLED BY APPLICANT WEB
FOOTER 06/04/2025 APPROVED MKRASKI
POOL DECK 06/04/2025 APPROVED MKRASKI
STEEL AND GROUND 05/13/2025 APPROVED MCONTRYMAN
Note: 5/12/2025 - PREVIOUS INSPECTION NOTES 5/12/25 1. There has been some wash in due to the rain. There is also water in the pool area so could not verify ties or all grounds, due to plastic covering the pool area on one side
STEEL AND GROUND 05/12/2025 Disapproved - NO FEE MCONTRYMAN
Note: 5/12/25 1. There has been some wash in due to the rain. There is also water in the pool area so could not verify ties or all grounds, due to plastic covering the pool area on one side

Review History

Department Status Date In Date Out
BLD COMPLETE 04/29/2025 04/30/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 04/29/2025 04/30/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 04/07/2025 04/10/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 2. Screen plans need to be digitally signed and sealed.
ELEC COMPLETE 04/07/2025 04/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BFLOOD COMPLETE 03/28/2025 04/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 03/28/2025 04/03/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Master plans have a different permit number on them. upload the copies you picked up from the city. 2. Screen plans need to be digitally signed and sealed.
ELEC HOLD 03/28/2025 04/03/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Master plans have a different permit number on them. upload the copies you picked up from the city.
MECH COMPLETE 03/28/2025 04/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/28/2025 03/31/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2025 03/28/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI GENERAL INSPECTION 32.50 ¤32.50 03/09/2026
RSI GENERAL INSPECTION 32.50 ¤32.50 03/09/2026
RSI GENERAL INSPECTION 32.50 ¤32.50 03/09/2026
EXTENSION ¤40.00 03/09/2026
INSPECTION- POOL ¤160.00 05/02/2025
PLAN REVIEW - RESIDENTIAL ¤65.00 05/02/2025
ADJUSTMENT 10% (¤25.50) 05/02/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/02/2025
SURCHARGE FS 533.721 ¤2.30 05/02/2025
SURCHARGE - FS 468.631 ¤3.44 05/02/2025
SW ENG INSPECTION 40 ¤40.00 05/02/2025
SW ENG - REVIEW 20 ¤20.00 05/02/2025
SITE PLAN 30 ¤30.00 05/02/2025
Fees Total Due: ¤0.00 Total Paid: ¤462.74