Permit #2025031360
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00160-0060 |
| Block: 00160 |
| Subdivision: 7023 - |
| Job Phone: 386-253-7621 |
| Location Address: 2 WHITLOW PL |
| Type: ME - MECHANICAL |
| Issue Date: 04/01/2025 |
| NOC: Unknown |
| Applicant name: STEVEN GLENN REYNOLDS |
| Owner: MUSSER DANIEL R & PAMELA J H&W |
|
Address 2 WHITLOW PLACE PALM COAST, FL 32164 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤8,876.00 |
| Job Description: HVAC CO LIKE FOR LIKE |
| Type: CN |
Contractor
CUNNINGHAM OIL COMPANY, INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
400 CARSWELL AVE PALM COAST, FL 32174 |
CAC1815644 (Exp: 08/31/2026) | 386-253-7621 | 386-254-5007 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 06/26/2025 | FINAL APPROVED | MKRASKI |
| HVAC FINAL | 06/11/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix item number 3 from previuos inspection Please fix new items #1-Ac unit mark wrong , technician replace breaker from Wh and not AC unit , AC unit still have 40 am breaker , unit call for 30 , please install the 50 am breaker that it was for WH #2-FBC-R . 302.6 seal all penetration , wall and ceiling ( low voltage wire AHU Plenum conduit ) around plenum ceiling 3. The back of the unit has alot of mositure coming from it. Please correct and seal properly --possible bad connection or gap from unit to duct-- | |||
| HVAC FINAL | 05/07/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 5/7/25 1. Roof penetrations need to be sealed 2. Arind top of AH unit, you can feel air. Please have corrected and seal properly 3. The back of the unit has alot of mositure coming from it. Please correct and seal properly --possible bad connection or gap from unit to duct-- |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/24/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/01/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/01/2025 |
| ADJUSTMENT 10% | (¤9.00) | 04/01/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/01/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 04/01/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |