I want to search for...

Permit #2025040126

Permit Details

Status: COED

CONDITIONED SPACE: 2077 sqft
GARAGE: 522 sqft
OPENED PORCH (WITH ROOF) : 187 sqft
Total Square Footage: 2786 sqft
Subdivision: 2343 - ENCLAVE AT SEMINOLE PALMS
Job Phone: 904-541-2326
Location Address: 214 ENCLAVE AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/29/2025
NOC: RECORDED
Applicant name: KENNETH LLOYD SMITH
Owner: CRE-K SEMINOLE WOODS OWNER, LLC

Address

14025 RIVEREDGE DR

TAMPA, FL 33637

Address

SUITE 175

TAMPA, FL 33637

Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

RICHMOND AMERICAN HOMES OF FLORIDA LP
Status Location Address State License Number Phone
ACTIVE

10255 FORTUNE PARKWAY, STE 150

JACKSONVILLE, FL 32256

CGC1519936 (Exp: 08/31/2026) 904-541-2326

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
JAMES T STERLING
Status Location Address Mailing Address State License Number Phone
ACTIVE

23 PANTHER LANE

PONTE VEDRA, FL 32081

SUITE 7

PONTE VEDRA, FL 32081

CCC1328645 (Exp: 08/31/2026) 904-908-4996

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 10/14/2025 FINAL APPROVED BHAINES
Note: 10/6/2025 - PREVIOUS INSPECTION NOTES 10/3/2025 - PREVIOUS INSPECTION NOTES Sewer cleanout needs to be located. reclaim meter pit needs cleaned out. Reclaim meter pit needs replaced.
U -UTILITY RESIDENTIAL FINAL 10/06/2025 Disapproved - NO FEE BHAINES
Note: 10/3/2025 - PREVIOUS INSPECTION NOTES Sewer cleanout needs to be located. reclaim meter pit needs cleaned out. Reclaim meter pit needs replaced.
ROW - FINAL APRON (AFTER POUR) 10/03/2025 APPROVED FSLADISH
Note: 10/3/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 10/03/2025 APPROVED FSLADISH
Note: 10/3/25 CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. 10/3/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________ ***INSPECTORS NOTE. YOU HAVE A FEW LOOSE PAVERS AT THE RIGHT SIDE DRIVEWAY APRON WING. ***
U -UTILITY RESIDENTIAL FINAL 10/03/2025 Disapproved - NO FEE BHAINES
Note: Sewer cleanout needs to be located. reclaim meter pit needs cleaned out.
U-CROSS CONNECTION 10/03/2025 APPROVED - AS NOTED BHAINES
Note: No CC, IRR using reclaim
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/30/2025 APPROVED FSLADISH
Note: 9/30/25 NEW SURVEY SHOWS THAT ELEVATIONS MEET COPC MINIMUM SURVEY STANDARDS AT THE TIME OF THIS REVIEW. ________________________________________________________________________________________________________________________ 9/18/2025 - PREVIOUS INSPECTION NOTES 9/18/25 YOU DO NOT HAVE THE FBC REQUIRED 6" FALL OFF OF REAR STRUCTUE. SEE PHOTO FOR REFERENCE E.Florida Building Code, Residential, Chapter 4, R401.3 Chapter 4, R401.3 Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E)
ROW FIELD SURVEY /GRADING CERTIFICATION 09/30/2025 APPROVED FSLADISH
Note: 9/30/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE. YOU HAVE A FEW LOOSE PAVERS AT THE RIGHT SIDE DRIVEWAY APRON WING. ***
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/18/2025 Disapproved - NO FEE FSLADISH
Note: 9/18/25 YOU DO NOT HAVE THE FBC REQUIRED 6" FALL OFF OF REAR STRUCTUE. SEE PHOTO FOR REFERENCE E.Florida Building Code, Residential, Chapter 4, R401.3 Chapter 4, R401.3 Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E)
BLD - BUILDING FINAL 09/17/2025 Approval - Private Provider PPROVIDER
ELECTRIC - EARLY POWER 09/08/2025 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 08/26/2025 APPROVED FSLADISH
Note: 8/26/25 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. 8/19/2025 - PREVIOUS INSPECTION NOTES 8/19/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 08/19/2025 APPROVED FSLADISH
Note: 8/19/25 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 08/19/2025 PARTIALLY APPROVED FSLADISH
Note: 8/19/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
LATH/BRICK/ WATER BARRIER 08/14/2025 Approval - Private Provider PPROVIDER
INSULATION 08/01/2025 Approval - Private Provider PPROVIDER
SEWER TIE IN 07/28/2025 APPROVED - AS NOTED MGIBSON
Note: 7/24/2025 - PREVIOUS INSPECTION NOTES 7/24/25 1. Plumbing concealed. Cannot complete inspection FBC [A]110.1 THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 07/24/2025 Approval - Private Provider PPROVIDER
SEWER TIE IN 07/24/2025 Disapproved - NO FEE MCONTRYMAN
Note: 7/24/25 1. Plumbing concealed. Cannot complete inspection FBC [A]110.1
ALL ROUGH 07/18/2025 Approval - Private Provider PPROVIDER
ELECTRIC-TUG 07/16/2025 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 07/14/2025 Approval - Private Provider PPROVIDER
WALL SHEATHING 07/11/2025 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/11/2025 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 06/20/2025 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 06/16/2025 Approval - Private Provider PPROVIDER
FORMBOARD SURVEY (OFFICE USE ONLY) 06/10/2025 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 06/10/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 06/10/2025 06/10/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please ensure when this lot is graded, it is graded as an A drainage with a rear yard swale swale going to the front of the home.
ENGIN1 COMPLETE 06/09/2025 06/10/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 06/09/2025 06/09/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 05/30/2025 06/02/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 05/27/2025 05/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 05/09/2025 05/12/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH HOLD 05/09/2025 05/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Repeat comments: 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 5. Plans show walls at 2x4 and corners at 2x6. Insulation on energy calcs does not correlate to the plans. 2x6 insulation should be less than 2x4 insulation
SW1 COMPLETE 05/09/2025 05/15/2025
Note: Released By: RODNEY RICKS - (386)986-2001 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/09/2025 05/09/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 04/02/2025 04/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 04/02/2025 04/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/02/2025 04/03/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Water/Sewer impact fees will be added at a later date after all utility agreements are final. Please note, a meter will not be installed until all agreements are complete.
ELEC COMPLETE 04/02/2025 04/07/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/02/2025 04/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/02/2025 04/04/2025
LOCATE COMPLETE 04/02/2025 04/11/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/02/2025 04/04/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on energy calcs and heatload need to be Daytona Beach 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition 3. Plans show R38 insulation in attic. Energy calcs say R45. Revise to match 4. Plans show 2x4 wall /2/6 walls. Energy calcs say CMU. Revise 5. Plans show walls at 2x4 and corners at 2x6. Insulation on energy calcs does not correlate to the plans. 2x6 insulation should be less than 2x4 insulation
SW1 HOLD 04/02/2025 04/07/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM No benchmark shown on site plan.
ZON HOLD 04/02/2025 04/03/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: sq ft of lot is incorrect the plat states 6992

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤874.47 05/30/2025
WATER- TURN ON ¤50.00 05/30/2025
WATER METER W/OUT TAP ¤965.03 05/30/2025
RECLAIM WATER PERMIT INSPECTIO ¤40.00 05/30/2025
WASTEWATER PERM INSPECTION ¤40.00 05/30/2025
WASTEWATER PERM REVIEW ¤25.00 05/30/2025
SEWER CAPITAL FACILITY ¤3,725.72 05/30/2025
WATER CAPITAL FACILITY FEE ¤3,149.89 05/30/2025
WATER PERMIT INSPECTION ¤40.00 05/30/2025
WATER PERMIT REVIEW ¤25.00 05/30/2025
SITE PLAN 30 ¤30.00 05/29/2025
SURCHARGE FS 533.721 ¤5.29 05/29/2025
SURCHARGE - FS 468.631 ¤7.93 05/29/2025
SW ENG - FOUNDATION SURVEY ¤20.00 05/29/2025
SW ENG INSPECTION 80 ¤80.00 05/29/2025
SW ENG PRE APRON ¤30.00 05/29/2025
SW ENG - REVIEW 20 ¤20.00 05/29/2025
SW ENG RES REVIEW 200 ¤200.00 05/29/2025
ADJUSTMENT 10% (¤33.73) 05/29/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/29/2025
ADMINISTRATIVE - RESID PP ¤225.00 05/29/2025
PLAN REVIEW - RESIDENTIAL ¤307.32 05/29/2025
FC IMPACT FEE EMS ¤62.00 05/29/2025
IMPACT FEE FIRE ¤434.51 05/29/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/29/2025
FC IMPACT FEE LIBRARY ¤268.00 05/29/2025
IMPACT FEE PARKS ¤1,828.01 05/29/2025
IMPACT FEE SCHOOL ¤5,450.00 05/29/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 05/29/2025
Fees Total Due: ¤0.00 Total Paid: ¤21,619.44